Interrogatory responses

Answers to questions 11

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy6 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files6

Text of CLF-011 Attachment 17.pdf

Extracted from the file · 142 pages · 272,863 characters

Text of CLF-011 Attachment 18.pdf

Extracted from the file · 22 pages · 55,502 characters

  1. Page 9 of 18

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 19 Page 9 of 18 Hearing Exhibit 115, Rebuttal Testimony of Jordan Mann Proceeding No. 25A-0044EG Page 9 of 17 1 The overall level of adoption of these technologies represents achievements that 2 are significantly higher than the current adoption levels achieved by existing DSM 3 offerings in the region. 4 The primary data collection, use of the Public Service prior DSM potential 5 study, actual mountain region customer data, and best-practice bass diffusion 6 forecasting methodologies together resulted in a study that is as accurate as 7 possible. In summary, the Potential Study reasonably assessed the potential of 8 various NPA measures to reduce peak gas demand. 9 B. Potential Study Adoption Rates 10 PLEASE OUTLINE INTERVENOR POSITIONS ON THE NPA ADOPTION 11 RATES ASSUMED USED IN THE POTENTIAL STUDY. 12 A. As noted in Ms. Klemm’s Rebuttal Testimony, Staff and Utility Consumer Advocate 13 (“UCA”) suggest the Company has overestimated the NPA measure adoption 14 rates,4 while MCC, SWEEP, and Sierra Club suggest the Company has 15 underestimated NPA measure adoption rates.5 16 HOW DID THE POTENTIAL STUDY CALCULATE ADOPTION RATES FOR 17 NPA MEASURES? 18 A. The Potential study relied on primary data collection from customers in the 19 mountain region to assess potential participants’ willingness to adopt peak gas 20 saving technologies. The percentage of customers willing to adopt a technology 21 with incentives equal to the full incremental cost of the technology is the expected 4 Hrg. Ex. 900 at 20:4-5 (LaMere Answer); Hrg. Ex. 400 at 17:15-17 (Henry-Sermos Answer). Hrg. Ex. 601 at 13:5-6 (Takahashi Answer); Hrg. Ex. 500 at 19:1-2 (Brant Answer); Hrg. Ex. 700, Rev. 1, at 21:4-6 (Brown Answer). 5
  2. Page 10 of 18

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 19 Page 10 of 18 Hearing Exhibit 115, Rebuttal Testimony of Jordan Mann Proceeding No. 25A-0044EG Page 10 of 17 1 long-run market share of a technology. The Potential Study used a bass diffusion 2 model to estimate each technology’s adoption, starting with the current market 3 share of the technology and ending at the expected long run market share of the 4 technology. The high level of incentives and intensive outreach activities planned 5 for the Mountain Energy Project led the team to choose relatively aggressive 6 adoption curve coefficients. Based on the novel nature of the Mountain Energy 7 Project, high level of incentives, and current low market share of electric space 8 heating technologies in the mountain region, the Company believes that this 9 forecast does have some level of uncertainty. Implementation of the NPA portfolio 10 will provide the Company evidence of actual customer uptake of the NPA portfolio 11 and assist the Company in determining whether adjustments to the NPA are 12 necessary to increase participation. The Company maintains that the potential 13 study, based upon reasonable adoption rates, accurately assesses the potential 14 savings available in the mountain region through the NPA portfolio.
  3. Page 11 of 18

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 19 Page 11 of 18 Hearing Exhibit 115, Rebuttal Testimony of Jordan Mann Proceeding No. 25A-0044EG Page 11 of 17 III. 1 WHAT IS THE PURPOSE OF THIS SECTION OF YOUR TESTIMONY? 2 3 NPA MEASURES A. This section of my testimony supports the discussion of the Potential Study’s 4 consideration of NPA measures in section II.B. of witness Klemm’s Rebuttal 5 Testimony. In particular, it addresses the savings that can be achieved through 6 the implementation of various NPA measures identified by MCC witness 7 Takahashi,6 including heat recovery ventilators and energy recovery ventilators 8 (“HRVs/ERVs”), snowmelt equipment, air-to-water heat pumps, low-flow 9 showerheads, water tank insulation, and pipe insulation. 10 WHAT WERE THE FINDINGS OF THE POTENTIAL STUDY WITH REGARD TO 11 HEAT OR ENERGY RECOVERY VENTILATORS? WHAT WAS THE BASIS OF 12 THAT ASSESSMENT? 13 A. The Potential Study did not forecast impacts from HRVs/ERVs because these 14 technologies have minimal impact on peak gas demand. In residential buildings, 15 the primary function of HRVs/ERVs is to provide ventilation and improve indoor air 16 quality by exchanging indoor and outdoor air. When compared to an existing 17 building without powered ventilation, HRVs/ERVs produce only improved 18 ventilation, with an accompanying increase in natural gas consumption to heat that 19 ventilation air during the winter, which would produce negative savings. For this 20 reason, this measure variant was not included in the Potential Study. 6 Hrg. Ex. 601 at 12:18-13:2 (Takahashi Answer).
  4. Page 12 of 18

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 19 Page 12 of 18 Hearing Exhibit 115, Rebuttal Testimony of Jordan Mann Proceeding No. 25A-0044EG Page 12 of 17 1 When compared to cheaper unbalanced powered ventilation systems, 2 which is an appropriate baseline for comparison, HRVs/ERVs can save energy by 3 recovering heat from the exhaust air to preheat incoming fresh air. While MCC 4 witness Takahashi states that “heat recovery ventilators and energy recovery 5 ventilators are highly cost-effective technologies capable of recovering up to 80– 6 90 percent of heating energy,”7 this represents the fraction of heating energy 7 required to heat up the ventilation air to indoor air temperature, which is only a 8 small fraction of the total heating energy needed at the premise. This HRV/ERV 9 effectiveness also measures savings against a balanced ventilation system 10 baseline, while savings against a more appropriate unbalanced ventilation system 11 baseline should also consider the interactions of infiltration and ventilation air. 12 During times of high infiltration, which include peak gas events, ERVs and HRVs 13 stop saving gas, because the high infiltration results in smaller incremental flow 14 from the unbalanced ventilation than the implied incremental flow from a balanced 15 ERV/HRV. Therefore, while HRVs and ERVs offer benefits over the course of the 16 winter heating season, they do not provide peak gas savings in residential 17 buildings and should not be included in the estimated peak gas saving potential. 7 Hrg. Ex. 601 at 52:3-5 (Takahashi Answer).
  5. Page 13 of 18

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 19 Page 13 of 18 Hearing Exhibit 115, Rebuttal Testimony of Jordan Mann Proceeding No. 25A-0044EG Page 13 of 17 1 WHAT WERE THE FINDINGS OF THE POTENTIAL STUDY WITH REGARD TO 2 SNOWMELT 3 ASSESSMENT? 4 A. EQUIPMENT? WHAT WAS THE BASIS OF THAT The Potential Study determined that snowmelt efficiency and electrification 5 measures faced significant barriers to adoption and would provide little reduction 6 to peak gas demand. To begin, very few customers have snowmelt systems. 7 Of the 359 8 residential customers surveyed, only seven (less than two percent of the sample) 9 reported having a snowmelt system.8 10 respondents, 13 (20 percent of the sample) reported having a snowmelt system.9 11 Next, snowmelt consumption during peak times is expected to be very small 12 relative to space heating. Snowmelt systems were expected to make up less than 13 0.1 percent of residential peak gas demand, and developing new residential 14 measures tailored to less than two percent of the population and such a small 15 percentage of the natural-gas peak was not a focus area for the NPA portfolio. 16 Within commercial buildings, it is estimated that snowmelt made up one to three 17 percent of peak gas consumption, depending on the customer type.10 Snowmelt 18 efficiency opportunities would generate small savings during peak and snowmelt 19 electrification is understood to be relatively difficult and not widely accepted in the 20 current market. 21 “(s)nowmelt systems are generally not recommended for operation during 8 Among the 66 commercial survey In addition, as indicated in the testimony of Mr. Takahashi, Hrg. Ex. 102, Attachment GKJ-2, Figure 4-18 at 36 (Jones Direct). Hrg. Ex. 102, Attachment GKJ-2, Figure 4-45 at 51 (Jones Direct). 10 Hrg. Ex. 102, Attachment GKJ-2, Table 4-2 at 19 (Jones Direct). 9
  6. Page 14 of 18

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 19 Page 14 of 18 Hearing Exhibit 115, Rebuttal Testimony of Jordan Mann Proceeding No. 25A-0044EG Page 14 of 17 1 extremely cold conditions because melting snow becomes more difficult and the 2 resulting water may quickly refreeze, creating safety hazards.”11 For all of these 3 reasons, snowmelt efficiency and electrification were expected to have minimal 4 impact on overall potential and the Company decided to focus its efforts on those 5 measures that provide the greatest potential to achieve the savings needed. 6 Snowmelt demand response was included as part of generalized commercial 7 demand response potential. 8 WHAT WERE THE FINDINGS OF THE POTENTIAL STUDY WITH REGARD TO 9 AIR-TO-WATER HEAT PUMPS? 10 ASSESSMENT? 11 A. WHAT WAS THE BASIS OF THAT The Potential Study did not forecast adoption for air-to-water heat pumps due to 12 low market availability for this technology. 13 emerging technology which heats water. Although this technology has gained 14 traction internationally, it has a very low market share in the United States. An air- 15 to-water heat pump could potentially displace an existing boiler system, but they 16 are not necessarily a one-to-one retrofit since many hydronic systems are 17 designed with higher supply temperatures than what is provided by an air-to-water 18 heat pump, which is an appropriate consideration given the NPA eligible area. 19 Additionally, for residential applications, these technologies are in direct 20 competition with air source heat pumps, including ductless mini split systems, 21 which have a higher market share and are likely a more practical retrofit or new 11 Hrg. Ex. 601 at 38:4-6 (Takahashi Answer). Air-to-water heat pumps are an
  7. Page 15 of 18

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 19 Page 15 of 18 Hearing Exhibit 115, Rebuttal Testimony of Jordan Mann Proceeding No. 25A-0044EG Page 15 of 17 1 construction solution. Displacement of boilers was modeled using air source heat 2 pump systems rather than air-to-water heat pumps and we maintain that the 3 approach taken in the Potential Study was a reasonable assessment. 4 inclusion of this technology ultimately would not change the total potential estimate 5 of boilers that switch to electric heat. 6 WHAT WERE THE FINDINGS OF THE POTENTIAL STUDY WITH REGARD TO 7 LOW-FLOW SHOWERHEADS, WATER TANK INSULATION, AND WATER 8 PIPE INSULATION? WAS THAT ASSESSMENT REASONABLE? 9 A. The The Potential Study did not forecast adoption for low-flow showerheads, water tank 10 insulation, and pipe insulation due to the minimal impacts on peak hour gas 11 savings, and the Company maintains that this approach was reasonable. 12 Residential water heating accounts for less than two percent of the peak hour gas 13 usage for the residential sector in the mountain region.12 Low-flow showerheads, 14 water tank insulation, and water pipe insulation would have the potential to save 15 only a small portion of that two percent of the load. 16 understanding that these low-cost measures are currently offered for free for 17 income qualified (“IQ”) customers and market rate customers through Energy 18 Squad visits through the Company’s DSM program. It is also my understanding 19 that Energy Squad visits are free for IQ customers and $100 for market rate 20 customers. While the peak hour gas impacts of these measures are de minimis, 21 the measures are available to customers should they wish to install them. 12 Hrg. Ex. 102, Attachment GKJ-2, Table 4-2 at 19 (Jones Direct). Furthermore, it is my
  8. Page 16 of 18

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 19 Page 16 of 18 Hearing Exhibit 115, Rebuttal Testimony of Jordan Mann Proceeding No. 25A-0044EG Page 16 of 17 DOES THIS CONCLUDE YOUR REBUTTAL TESTIMONY? 1 2 A. Yes, it does.
  9. Page 17 of 18

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 19 Page 17 of 18 Hearing Exhibit 115, Rebuttal Testimony of Jordan Mann Proceeding No. 25A-0044EG Page 17 of 17 Statement of Qualifications Jordan Mann Jordan Mann is employed by Apex Analytics LLC (“Apex”) as a Project Director. In that role, he works with electric utilities, gas utilities, state energy offices, and the DOE to provide decarbonization strategies for the built environment. Mr. Mann is currently working on or has recently completed potential studies, baseline stock analyses, and energy efficiency portfolio development support projects. Prior to joining Apex Analytics, Mr. Mann worked at Guidehouse for over 10 years in their energy efficiency data sciences and engineering group. Prior to Guidehouse, he worked at the Fraunhofer Institute for Solar Energy Research in Freiburg, Germany where he researched hydronic heating systems and efficiency of ground source heat pumps. Mr. Mann has an undergraduate degree in mechanical engineering and a master’s degree in building systems engineering with a master’s thesis in fault detection, energy use, and operation of gas heated hydronic heating systems.
  10. Page 18 of 18

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 19 Page 18 of 18 BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF COLORADO * * * * * IN THE MATTER OF THE PUBLIC APPLICATION OF SERVICE COMPANY OF COLORADO FOR APPROVAL OF THE MOUNTAIN ENERGY PROJECT AND ASSOCIATED CERTIFICATE OF PUBLIC CONVENIENCE AND NECESSITY FOR SUPPLEMENTAL SUPPLY ) ) ) ) ) ) ) ) ) PROCEEDING NO. 25A-0044EG AFFIDAVIT OF JORDAN MANN ON BEHALF OF PUBLIC SERVICE COMPANY OF COLORADO I, Jordan Mann, being duly sworn, state that the Rebuttal Testimony was prepared by me or under my supervision, control, and direction; that the Rebuttal Testimony is true and correct to the best of my information, knowledge and belief; and that I would give the same testimony orally if asked under oath. Dated at Boulder, Colorado, this 30 th day of June, 2025. Jordan Mann Project Director Subscribed and sworn to before me this 3Q rth day of June, 2025. SARAH BELKIN NOTARY PUBLIC STATE OF COLORADO NOTARY ID 20174013990 MY COMMISSION EXPIRES MARCH 31, 2029 Notary Public My Commissio l \ expires 1n.:3 1.-0uC\

As listed on the current system

Question(s) Answered 11 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/27/2026

This filing on the current system (opens in a new tab)