Interrogatory responses
Answers to questions 11
Files8
CLF-011 Attachment 25.pdf
PDF · 1.7 MB · 5 pagesText searchable
Download CLF-011 Attachment 25.pdfRead the text of CLF-011 Attachment 25.pdf
CLF-011 Attachment 26.pdf
PDF · 876 KB · 4 pagesText searchable
Download CLF-011 Attachment 26.pdfRead the text of CLF-011 Attachment 26.pdf
CLF-011 Attachment 27.pdf
PDF · 1.6 MB · 3 pagesText searchable
Download CLF-011 Attachment 27.pdfRead the text of CLF-011 Attachment 27.pdf
CLF-011 Attachment 28.pdf
PDF · 1.5 MB · 4 pagesText searchable
Download CLF-011 Attachment 28.pdfRead the text of CLF-011 Attachment 28.pdf
CLF-011 Attachment 29.pdf
PDF · 1.7 MB · 5 pagesText searchable
Download CLF-011 Attachment 29.pdfRead the text of CLF-011 Attachment 29.pdf
CLF-011 Attachment 30.pdf
PDF · 4.9 MB · 47 pagesText searchable
Download CLF-011 Attachment 30.pdfRead the text of CLF-011 Attachment 30.pdf
CLF-011 Attachment 31.pdf
PDF · 4.5 MB · 65 pagesText searchable
Download CLF-011 Attachment 31.pdfRead the text of CLF-011 Attachment 31.pdf
CLF-011 Attachment 32.pdf
PDF · 1.6 MB · 11 pagesText searchable
Download CLF-011 Attachment 32.pdfRead the text of CLF-011 Attachment 32.pdf
Text of CLF-011 Attachment 28.pdf
Extracted from the file · 4 pages · 6,964 characters
Text of CLF-011 Attachment 29.pdf
Extracted from the file · 5 pages · 11,434 characters
Text of CLF-011 Attachment 30.pdf
Extracted from the file · 47 pages · 125,202 characters
Page 41 of 65
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 31 Page 41 of 65 References NEEA, HVAC Market Actor Profile Report, October 15, 2020 NEEA, Rooftop HVAC Market Characterization Study, February 16, 2017 Seventhwave and CEE, Commercial Roof-top Units in Minnesota: Characteristics and Energy Performance, March 2017 E Source, Sending Your DSM Measures Upstream, August 20, 2019 NMR Group, Inc. and Apex Analytics, Characterization of HVAC Supply Chains in Northern Illinois, November 12, 2019 Bonneville Power Administration, HVAC Market Intelligence Report, April 2016 Bonneville Power Administration, Commercial HVAC Market Characterization, July 2015 Primary interviews of HVAC program managers, Summer 2021 ACHR News (Website), September 2021 HVAC & Refrigeration Insider (Website), September 2021 HVACR Business Magazine (Website), September 2021 HVAC Market Actor Profile EcoMetric 39Page 42 of 65
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 31 Page 42 of 65 Appendix A: Data Collection Instruments Focus Group Screener and Guide My name is [NAME], calling from [COMPANY] Department of Commerce that will help Minnesota utilities like Xcel, CenterPoint, and OtterTail, just to name a few, improve their energy efficiency programs. We are planning to hold online focus groups with commercial HVAC contractors to learn about your work. We want to understand how you approach projects and the decisions you make so that utilities can design efficiency programs that fit better with the way you do your work. We value your experience and opinions and would really appreciate the chance to include you. We expect the focus group to take 90 minutes. We will provide an electronic gift card for $200 in appreciation for your time and input. Would you be interested in joining us for this type of discussion with other HVAC contractors? [IF CONCERNED ABOUT LEGITIMACY] If you have questions about this study, you can reach out to [CONTACT NAME] at [EMAIL]. Screening [IF INTERESTED IN PARTICIPATING] you would be a good fit for a focus group. ons to make sure [ASK ALL] S1. About how many HVAC systems did your company install in each of the following types of buildings in the past year? Building Type Less than 10 10 to 24 25 to 99 Residential 100 or more - - - - Commercial, 25 tons or less - - - - Commercial, greater than 25 tons - - - - [IF COMMERCIAL, 25 TONS OR LESS = LESS THAN 10, GO TO TERMINATION SCRIPT] [ASK ALL] S2. How are you typically involved in commercial HVAC projects, installing equipment 25 tons or less. Are you involved in: a. Sales b. Advising on or recommending equipment types c. Installation Title or Partial Title of Report Name of Grantee 40Page 43 of 65
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 31 Page 43 of 65 Appendix A: Data Collection Instruments d. What other ways are you involved? [IF NOT INVOLVED IN SALES, RECOMMENDING EQUIPMENT TYPES, OR INSTALLATION] S3. We would really like to speak with people who are more closely involved in decisions around which types of HVAC equipment are installed in commercial projects and how that equipment is installed. Is there someone else in your company involved in sales or installation for small-tomedium commercial projects that might be able to participate in our discussion? A. Yes [ASK TO SPEAK WITH THAT PERSON AND RETURN TO INTRODUCTION; IF NOT AVAILABLE, LEAVE MESSAGE AND RECORD CONTACT INFORMATION] b. No [GO TO TERMINATION SCRIPT] Classification Great, I would like to gather a few details about your company to help us make sure we get a representative group. [IF LOCATION = SOUTHERN MN] S4. What proportion of your commercial HVAC installations for systems 25 tons or less take place in the Twin Cities metro area? a. [RECORD OPEN-ENDED RESPONSE [ASK ALL] S5. Does your company operate from more than one location? a. Yes b. No [ASK ALL] S6. How many employees does your company have at your location? a. [RECORD OPEN-ENDED RESPONSE IF SINGLE LO COMPANY GROUP; IF SINGLE LOCATION AND <10 ASSIGN TO SMALL COMPANY GROUP] [IF MULTIPLE LOCATIONS] S7. How many employees does your company have across all its locations? a. [RECORD OPEN-ENDED RESPONSE <10 ASSIGN TO SMALL COMPANY GROUP] GROUP; IF [ASK ALL] HVAC Market Actor Profile EcoMetric 41Page 44 of 65
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 31 Page 44 of 65 Appendix A: Data Collection Instruments S8. Do you or your customers installing commercial HVAC systems 25 tons or less receive rebates from utilities for installing energy efficient systems? a. Yes b. No c. [IF RECEIVE REBATES] S9. What utilities provide those rebates? a. [RECORD OPEN-ENDED RESPONSE] [IF RECEIVE REBATES] S10. Roughly what proportion of the commercial HVAC systems you install that are smaller than 25 tons receive rebates? a. [RECORD OPEN-ENDED RESPONSE] Closing [ASK ALL] S11. It sounds like you would be a great fit for our research. We are planning on holding discussions with groups of about six contractors, using video conferencing software. Do you have access to reliable internet and a web camera, and are you comfortable participating in that type of discussion? a. Yes b. No [IF NOT ABLE/COMFORTABLE] S12. What type of support, if any, could we provide that would enable you to participate? [IF PARTICIPANT HAS CONFIDENTIALITY CONCERNS, INFORM THEM THAT, WHILE THE DISCUSSION WILL BE RECORDED, THE RECORDING WILL NOT BE AVAILABLE PUBLICLY, AND REPORTING WILL NOT IDENTIFY ANY INDIVIDUAL RESPONDENTS.] a. [OPEN-ENDED RESPONSE] Thank you for the information you have given us so far. We will consider whether we can provide the support you need and reach out to you if we can. [IF ABLE/COMFORTABLE] S13. We are planning to hold our discussion on [DATE] from [START TIME] to [END TIME]. As a reminder, you would receive $200 in appreciation for your time and input. Are you available to participate? HVAC Market Actor Profile EcoMetric 42Page 45 of 65
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 31 Page 45 of 65 Appendix A: Data Collection Instruments a. Yes b. No [IF NOT AVAILABLE] S14. Is there someone else in your company involved in sales or installation for commercial HVAC projects 25 tons or less that might be able to participate in a focus group? a. Yes [ASK TO SPEAK WITH THAT PERSON AND RETURN TO INTRODUCTION; IF NOT AVAILABLE, RECORD CONTACT INFORMATION AND LEAVE MESSAGE] b. No [IF NOT AVAILABLE] S15. These discussions are part of a larger research project, and we will be reaching out to contractors to participate in other ways. Like with the focus groups, we will offer a monetary incentive for your time and input. May we contact you about other opportunities to participate in this research? a. Yes b. No Thank you very much for your time. [IF AGREED TO FURTHER CONTACT] We will reach out again about our other research opportunities. [IF AVAILABLE] S16. Thank you very much, we look forward to having you be part of our discussion. [PROVIDE PARTICIPATION DETAILS IF AVAILABLE]. [NAME] from our research team will be in touch with you soon to give you additional details about how to participate. Please provide the best e-mail address and phone number for us to reach you: a. Email: [RECORD E-MAIL ADDRESS] b. Phone: [RECORD PHONE NUMBER] Termination y to people who work in specific places and roles in HVAC installation. We regret that our current study is not a good match for you. Pre-Group Questionnaire Thank you for participating in our discussion. As we wait for everyone to arrive, please answer the following questions to give us some additional background information about your business. HVAC Market Actor Profile EcoMetric 43Page 46 of 65
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 31 Page 46 of 65 Appendix A: Data Collection Instruments 1. What proportion of your commercial HVAC installations for systems 25 tons or less fall into each of the following categories? [Check that responses total 100%, probe if they do not] Project Type % of Commercial Installations 25 Tons or Less Equipment replacement: Installing new equipment to replace existing equipment or an existing system that may or may not still be functional. - Plan and specify new construction: Installing a new system where one did not previously exist or has been completely removed, based on a design and specifications provided to you. - Design/build new construction: Installing a new system where one did not previously exist or has been completely removed, based on a design you develop. - Other: [ - ] Introduction (5 min, start at 0:00) Hello everyone, and thanks for joining us today. My name is [NAME]. As we mentioned when we Minnesota Commerce Department that will help utilities in the state improve their energy efficiency programs. The goal of our research, and this conversation, is to better understand what it is like to be a HVAC project, what decisions get made along the way, and what you need to take into consideration as you make those decisions. Our goal is to help utilities design programs that fit better with the realities of the commercial HVAC industry. Before we get started, there are a few housekeeping items I need to go over: 1. I know there are lots focused on the discussion, just like you would if we were in a room together. 2. each other, and conversations online can be a little awkward. So, we will need to give each other a little extra slack and patience. 3. We want to learn about how things work differently as well as what is similar for each of you. We welcome different opinions. 4. call on you. Or, if you have been talking a lot, I might ask you to give someone else a turn. I appreciate your understanding and cooperation in making sure everyone gets to speak. 5. Our discussion will take 90 minutes. We will take a five-minute break partway through, but if K. We hope you will come back as soon as you can. HVAC Market Actor Profile EcoMetric 44Page 47 of 65
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 31 Page 47 of 65 Appendix A: Data Collection Instruments 6. If there is background noise where you are, please mute yourself when you are not speaking. 7. Some people will be listening-in to our discussion today. Some of my colleagues and [LIST ANY OBSERVERS FROM THE DEPARTMENT AND/OR UTILITIES] are on the line. 8. As I mentioned, our goal is to learn from your experience and expertise, and we appreciate your honesty. Nothing you say tonight is going to have any impact on your relationships with utility programs or anything like that. 9. We will be video and audio recording the conversation today. We may share the recordings with 10. Our report will not include any information that identifies individual respondents. Any questions before we begin? Warm-Up Question (5 min, start at 0:05) Q1. First, I would like to go around and have everyone tell us your name and one way your work has fore as things everyone to talk most of the time we can let the conversation flow more naturally. Motivations (10 min, start at 0:10) Q2. To start with, please quickly take me through a typical day: How is it structured? What kinds of things are you doing? a. Is that the same for everyone? How is the structure of your day different? b. How much variation is there in the kinds of things you do from one day to the next? Q3. What makes a day a good day for you? a. What are the most rewarding parts of your job? b. Are there some types of installations you like more than others? Q4. And what makes a bad day? a. What is the most challenging part of your job? b. What is the most frustrating part of your job? Project Decision-Making Equipment Replacement (15 min, start at 0:20) Q5. an equipment replacement scenario. [REFERENCE SCREENER/PRE-GROUP QUESTIONNAIRE DATA ABOUT FREQUENCY OF PROJECTS BY TYPE] HVAC Market Actor Profile EcoMetric 45Page 48 of 65
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 31 Page 48 of 65 Appendix A: Data Collection Instruments How do you typically find equipment replacement work? [IF NEEDED, PROBE ON: MAINTENANCE CONTRACTS, RELATIONSHIPS WITH EXISTING CUSTOMERS, REFERRALS, MARKETING, ETC.] Q6. How often do you recommend the equipment to install in a replacement scenario, as opposed to having it specified by someone else? a. Who typically specifies the equipment in a replacement scenario if it is not you? b. Are there certain types of projects or certain types of customers where it is more likely that someone else will specify the equipment for a replacement? Q7. What, if anything, would lead you suggest a type of equipment other than the existing equipment type in a replacement scenario? a. What prevents you from suggesting different equipment types more often? b. When, if ever, would you suggest customers switch from gas equipment to electric equipment in a replacement scenario? How often does that occur? Q8. What about the efficiency of the equipment itself: how often do you suggest equipment that has a higher efficiency level in a replacement, as opposed to one that just meets code? a. In what types of projects or for which types of customers are you more likely to recommend high efficiency equipment? b. What prevents you from recommending higher efficiency systems more often? c. How receptive are customers to higher efficiency systems when you suggest them? Q9. Who do you look to for information to inform your recommendations in an equipment replacement scenario? a. What information do you look for from the end-user? b. What role does your distributor play in helping identify options to recommend? c. When would you bring in an engineer? Do you have that capability on your staff? If not, how would you find one? Plan & Spec New Construction (10 min, start at 0:35) Q10. [REFERENCE SCREENER/PREGROUP QUESTIONNAIRE DATA ABOUT FREQUENCY OF PROJECTS BY TYPE]. How do you typically find plan and spec work? How often are you responding to open bids, as opposed to more limited requests for proposals? a. What, if anything, do you do to differentiate your proposals in plan and spec work, or is the competition just based on price? HVAC Market Actor Profile EcoMetric 46Page 49 of 65
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 31 Page 49 of 65 Appendix A: Data Collection Instruments b. What types of customers or types of buildings are more likely to take a plan and spec approach? Q11. Who typically specifies the equipment in the plan and spec projects you work on? Q12. In what types of situations might you suggest changes to the equipment or design specified in a plan and spec project? a. How often does that happen? b. Who do you make those recommendations to? A general contractor? The building owner? c. How receptive are they, typically, to your suggestions? Q13. How do you work with distributors on a plan and spec project? [IF NEEDED] What, if anything, do they do beyond providing pricing and filling the order for the equipment? Design/Build New Construction (15 min, start at 0:45) Q14. And f a. What types of customers or types of buildings are more likely to do design/build projects? Q15. What are your most important considerations when you are deciding what type of system to recommend in a design/build project? a. What information do you need to decide what type of system to recommend? b. How do you get that information? c. How do you decide what fuel type to use (gas or electric) when you are designing a system for a design/build project? What might lead you to select an efficient electric option over gas? Q16. Who is involved in designing the system for a design/build project? a. What design capabilities do you have internally, and what would you have to look for outside advice on? Who would you look to for that advice? b. [IF NOT ADDRESSED] What information or advice, if any, would distributors provide? c. [IF NOT ADDRESSED] When would you seek advice from an engineer? How would you find an engineer to help with that? Q17. And what about selecting the specific equipment, once you have settled on a system design: What are your most important considerations in that step? a. What information do you need to select specific equipment types? b. How do you get that information? HVAC Market Actor Profile EcoMetric 47Page 50 of 65
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 31 Page 50 of 65 Appendix A: Data Collection Instruments c. What role do distributors play in selecting the specific equipment to recommend? Break (5 min, start at 1:00) take a break from looking at the screen for a few minutes. Please be back promptly in five minutes, at [TIME] Poll Question: How frequently do you install equipment that is more efficient than energy code requires in each project type? Project Type Never or almost never Rarely About half the time Often Always or almost always Equipment Replacement - - - - - Plan & Spec New Construction - - - - - Design/Build New Construction - - - - - Energy Efficiency (15 min, start at 1:05) Q18. It looks like people are most likely to install efficient equipment in [DISPLAY AND REFERENCE POLL RESPONSES]. Why is that? Q19. And it looks like people are less likely to install efficient equipment in [REFERENCE POLL RESPONSES]. What prevents you from installing efficient equipment more often in those types of projects? Q20. Beyond project type, in what situations are you more likely to install a system that is more efficient than code? a. Are there certain types of customers that are more likely to install above-code systems? b. Are there certain types of equipment where you are more likely to install above-code options? Q21. When you are recommending equipment, do you always recommend an above-code option? a. [IF NOT] How do you decide when to recommend an above code option? Q22. How does installing a more efficient system compare to a system that just meets code from a business perspective? HVAC Market Actor Profile EcoMetric 48
Text of CLF-011 Attachment 32.pdf
Extracted from the file · 11 pages · 34,299 characters
As listed on the current system
Question(s) Answered 11 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/27/2026