Interrogatory responses
Answers to questions 5, 13, 20
Files10
NECTA-005_Final.pdf
PDF · 86 KB · 1 pageText searchable
Download NECTA-005_Final.pdfRead the text of NECTA-005_Final.pdf
NECTA-005 Attachment 1.pdf
PDF · 763 KB · 1 pageText searchable
Download NECTA-005 Attachment 1.pdfRead the text of NECTA-005 Attachment 1.pdf
NECTA-013_Final.pdf
PDF · 121 KB · 2 pagesText searchable
Download NECTA-013_Final.pdfRead the text of NECTA-013_Final.pdf
NECTA-020_Final.pdf
PDF · 112 KB · 1 pageText searchable
Download NECTA-020_Final.pdfRead the text of NECTA-020_Final.pdf
NECTA-020 Attachment 1.pdf
PDF · 798 KB · 1 pageText searchable
Download NECTA-020 Attachment 1.pdfRead the text of NECTA-020 Attachment 1.pdf
NECTA-020 Attachment 2.pdf
PDF · 1.2 MB · 9 pagesText searchable
Download NECTA-020 Attachment 2.pdfRead the text of NECTA-020 Attachment 2.pdf
NECTA-020 Attachment 3 REDACTED.pdf
PDF · 1.7 MB · 7 pagesText searchable
Download NECTA-020 Attachment 3 REDACTED.pdfRead the text of NECTA-020 Attachment 3 REDACTED.pdf
NECTA-020 Attachment 4.pdf
PDF · 1.1 MB · 5 pagesText searchable
Download NECTA-020 Attachment 4.pdfRead the text of NECTA-020 Attachment 4.pdf
NECTA-020 Attachment 5.pdf
PDF · 1.1 MB · 6 pagesText searchable
Download NECTA-020 Attachment 5.pdfRead the text of NECTA-020 Attachment 5.pdf
NECTA-020 Attachment 6.pdf
PDF · 1.5 MB · 8 pagesText searchable
Download NECTA-020 Attachment 6.pdfRead the text of NECTA-020 Attachment 6.pdf
Text of NECTA-020_Final.pdf
Extracted from the file · 1 page · 1,075 characters
Text of NECTA-020 Attachment 1.pdf
Extracted from the file · 1 page · 179 characters
Page 1
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-020 Attachment 2 Page 1 of 9 ETL Analysis Maximo to AldenOne to Maximo Maximo To Alden One This First interface covers two conversations between Alden One and Maximo, i.e., NS1 and NS3. NS1: When a work order for pole installs, replacement, or removal gets its CU design approved and moved to a Status of ‘APPR’. ETL will send work order header information related to the work to Alden One labelled as header information. And pole information related to the work to Alden One labelled as pole information will be sent. Both are part of the NS1 handshake. ETL will send this information in a flat file as target to EDI.EDI will push the file to Alden One server. Since EDI archives the NS1 file for 90 days, ETL will not archive the files in Unix server. NS3: When the pole install, replacement or removal work gets completed and the work order moves to a Status of ‘FCOMP’ the Alden One record needs to be updated. Maximo will send the In-Service Date and the NS3 handshake. ETL will create the flat file as target to EDI. EDI will push the file to Alden One server. Since EDI archives the NS3 file for 90 days, ETL will not archive the files in Unix server 1. Autosys / Scheduling Job: WAMEP_MAXIMO_ALDENONE_NS1_BOX WAMEP_MAXIMO_ALDENONE_NS3_BOX Description - Work Order Notification Details from Maximo to AldenOne. Frequency - Weekdays-Once a day , mo,tu,we,th,fr ; 8:00:00 PM 2. ETL / Informatica Flow: - Workflow Mapping Session wkf_MAXIMO_to_ALDENONE_NS1Select m_WAME_MAXIMO_to_ALDENONE_NS1Select s_WAME_MAXIMO_to_ALDENONE_NS1Select wkf_MAXIMO_to_ALDENONE_NS1Select m_WAME_File_to_AldenOne_NS1 s_WAME_File_to_AldenOne_NS1 wkf_MAXIMO_to_ALDENONE_NS1Select m_WAME_MAXIMO_to_ALDENONE_NS1MarkSent s_WAME_MAXIMO_to_ALDENONE_NS1MarkSent wkf_MAXIMO_to_ALDENONE_NS3Select m_WAME_MAXIMO_to_ALDENONE_NS3Select s_WAME_MAXIMO_to_ALDENONE_NS3Select wkf_MAXIMO_to_ALDENONE_NS3Select m_WAME_File_to_AldenOne_NS3 s_WAME_File_to_AldenOne_NS3 wkf_MAXIMO_to_ALDENONE_NS3Select m_WAME_MAXIMO_to_ALDENONE_NS3MarkSent s_WAME_MAXIMO_to_ALDENONE_NS3MarkSent Mapping 1 - m_WAME_MAXIMO_to_ALDENONE_NS1Select Source Table: NTFY_WONUM_CONVRSATN_HDR Target Table: NTFY_WONUM_CONVRSATN_HDR 1 9/17/2026Page 2
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-020 Attachment 2 Page 2 of 9 ETL Analysis Maximo to AldenOne to Maximo This mapping only calls the legacy stored Procedure ESMAXIMO.CTRL_NOTIFY_MAXIMO.NS1_Select_For_Send. Hence it uses a dummy table as Source and Target and a dummy SQL that returns zero rows. Then a file is created out of the data and is sent to ALDEN through BizManager. Mapping 2 - m_WAME_File_to_AldenOne_NS1 The purpose of this mapping is to create the NS1 file for AldenOne using which they can create conversation number for the related Maximo workorder. Source File - NS1_File_Source Target File - File_To_AldenOne_NS1 (The target file is being generated here.) Source qualifier query – 2 9/17/2026Page 3
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-020 Attachment 2 Page 3 of 9 ETL Analysis Maximo to AldenOne to Maximo Mapping 3 - m_WAME_MAXIMO_to_ALDENONE_NS1MarkSent This mapping will call the stored procedure ESMAXIMO.CTRL_NOTIFY_MAXIMO.NS1_MARK_SENT and stored proc will marks the NS1 file as sent to AldenOne Source Table - NTFY_WONUM_CONVRSATN_HDR Target table - NTFY_WONUM_CONVRSATN_HDR 3 9/17/2026Page 4
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-020 Attachment 2 Page 4 of 9 ETL Analysis Maximo to AldenOne to Maximo NS3 -Select Mapping 1 - m_WAME_MAXIMO_to_ALDENONE_NS3Select This mapping only calls the legacy stored Procedure ESMAXIMO.CTRL_NOTIFY_MAXIMO.NS3_Select_For_Send. Hence it uses a dummy table as Source and Target and a dummy SQL that returns zero rows. Then it would invoke the store procedure which subsequently will prepare the data for ETL. Source table – NTFY_WONUM_CONVRSATN_HDR Target Table - NTFY_WONUM_CONVRSATN_HDR Mapping 2 - m_WAME_File_to_AldenOne_NS3 This mapping will create NS3 file for Alden One which will contain Maximo workorder updates. Source - NTFY_WONUM_CONVRSATN_HDR Target - File_to_AldenOne_NS3 Source Qualifier query – SELECT LTRIM(TO_CHAR(WONUM)) ||'|'||LTRIM(TO_CHAR(NTFY_CONVRSATN_ID)) ||'|'||'POLESET COMPLETE' AS VARTXT FROM ESMAXIMO.NTFY_WONUM_CONVRSATN_HDR WHERE NTFY_CONVRSATN_STAT_NM = 'NS3 Ready' AND NVL(NTFY_CONVRSATN_ID,0) != 0 4 9/17/2026Page 5
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-020 Attachment 2 Page 5 of 9 ETL Analysis Maximo to AldenOne to Maximo Mapping 3 - m_WAME_MAXIMO_to_ALDENONE_NS3MarkSent This mapping invokes the stored procedure which marks the NS3 file as sent to AldenOne. This mapping will contain dummy source and target and will just be used to call the legacy stored procedure ESMAXIMO.CTRL_NOTIFY_MAXIMO.NS3_Mark_Sent Source and target table - NTFY_WONUM_CONVRSATN_HDR Alden One To Maximo – Scope of this interface covers two conversations between Alden One and Maximo, i.e., NS2 and NS4. File will be received by Biz Manager from Alden One, then Biz Manager will place the file in Informatica UNIX directory. Informatica will translate it as per the transformation rules defined in the mapping sheet, before sending the data back to the Maximo interface tables using stored procedures. 5 9/17/2026Page 6
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-020 Attachment 2 Page 6 of 9 ETL Analysis Maximo to AldenOne to Maximo 1. Autosys / Scheduling Job: • WAMEP_AldenOne_MAXIMO_NS2_BOX → Desc: Work Order Notification Details from AldenOne to Maximo. Freq: Weekday, 10:00:00 PM • WAMEP_AldenOne_MAXIMO_NS2Report_BOX → Freq: Weekday, 10:05:00 PM • WAMEP_AldenOne_MAXIMO_NS4_BOX → Desc: Work Order Notification Details from Maximo to AldenOne. Freq: Weekday, 10:00:00 PM • WAMEP_AldenOne_MAXIMO_NS4Report_BOX → Freq: Weekday, 10:10:00 PM 2. ETL informatica:Workflow Mapping Session wkf_WAME_AldenOne_MAXIMO_NS2 m_WAME_AldenOne_MAXIMO_NS2 s_WAME_AldenOne_MAXIMO_NS2 wkf_WAME_AldenOne_MAXIMO_NS2Report m_WAME_AldenOne_MAXIMO_NS2Report s_WAME_AldenOne_MAXIMO_NS2Report wkf_WAME_AldenOne_MAXIMO_NS4 m_WAME_AldenOne_MAXIMO_NS4 s_WAME_AldenOne_MAXIMO_NS4 wkf_WAME_AldenOne_MAXIMO_NS4Report m_WAME_AldenOne_MAXIMO_NS4Report s_WAME_AldenOne_MAXIMO_NS4Report NS2 – This mapping is for processing the NS2 file which is received from BizManager. Informatica Mapping will invoke the stored procedure ESMAXIMO.CTRL_NOTIFY_MAXIMO.NS2_Post to delete the Staging table data from the previous run. It then pulls the file from its UNIX directory and populates intermediate staging table NTFY_WONUM_CONVRSATN_STAGEG by invoking stored procedure NS2_POST, after applying the transformation rules as per the mapping sheet. Mapping - m_WAME_AldenOne_MAXIMO_NS2 Source File - NS2MaximoAldenOne Target table - NTFY_WONUM_CONVRSATN_STAGEG 6 9/17/2026Page 7
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-020 Attachment 2 Page 7 of 9 ETL Analysis Maximo to AldenOne to Maximo Mapping - m_WAME_AldenOne_MAXIMO_NS2Report This mapping fetches records from Maximo interface table invokes stored proc ESMAXIMO.CTRL_NOTIFY_MAXIMO.NS2_Report. This procedure takes the information present in the table and generates a report. This report is generated and is ready to be emailed. In the end, it updates the ESMAXIMO.INTRFC_CTRL table with the new run date. 7 9/17/2026Page 8
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-020 Attachment 2 Page 8 of 9 ETL Analysis Maximo to AldenOne to Maximo Mapping - m_WAME_AldenOne_MAXIMO_NS4 This mapping is for processing the NS4 file which is received from BizManager. Informatica Mapping will invoke the stored procedure NS4_DELETE_STAGING to delete the Staging table data from the previous run. It then pulls the file from its UNIX directory and populates intermediate staging table NTFY_WONUM_CONVRSATN_STAGEG by invoking stored procedure NS4_POST, after applying the transformation rules as per the mapping sheet. Mapping - m_WAME_AldenOne_MAXIMO_NS4Report This mapping fetches records from Maximo interface table invokes stored proc ESMAXIMO.CTRL_NOTIFY_MAXIMO.NS4_Report. This procedure takes the information present in the ESMAXIMO.NTFY_WONUM_CONVRSATN_AUDIT table and generates a report. This report is generated and is ready to be emailed. In the end, it updates the ESMAXIMO.INTRFC_CTRL table with the new run date. 8 9/17/2026Page 9
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-020 Attachment 2 Page 9 of 9 ETL Analysis Maximo to AldenOne to Maximo 3. No process change identified at ETL side. 9 9/17/2026
Text of NECTA-020 Attachment 3 REDACTED.pdf
Extracted from the file · 7 pages · 7,964 characters
Text of NECTA-020 Attachment 4.pdf
Extracted from the file · 5 pages · 2,573 characters
Text of NECTA-020 Attachment 5.pdf
Extracted from the file · 6 pages · 12,657 characters
Text of NECTA-020 Attachment 6.pdf
Extracted from the file · 8 pages · 6,714 characters
As listed on the current system
Question(s) Answered 5, 13, 20 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 09/23/2026