Interrogatory responses
Answers to questions 785, 786, 789, 791
Files6
OCC-785_Final.pdf
PDF · 88 KB · 1 pageText searchable
Download OCC-785_Final.pdfRead the text of OCC-785_Final.pdf
OCC-786_Final.pdf
PDF · 90 KB · 1 pageText searchable
Download OCC-786_Final.pdfRead the text of OCC-786_Final.pdf
OCC-786 Attachment 1 .pdf
PDF · 99 KB · 1 pageText searchable
Download OCC-786 Attachment 1 .pdfRead the text of OCC-786 Attachment 1 .pdf
OCC-786 Attachment 1 .xlsx
Excel · 25 KBText searchable
Download OCC-786 Attachment 1 .xlsxRead the text of OCC-786 Attachment 1 .xlsx
OCC-789_Final.pdf
PDF · 122 KB · 2 pagesText searchable
Download OCC-789_Final.pdfRead the text of OCC-789_Final.pdf
OCC-791_Final.pdf
PDF · 86 KB · 1 pageText searchable
Download OCC-791_Final.pdfRead the text of OCC-791_Final.pdf
Text of OCC-786 Attachment 1 .xlsx
Extracted from the file
Page 1
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-19 Date Issued September 21, 2026 OCC-789 Page 1 of 2 Date Filed: October 05, 2026 Witness: Leanne M. Landry and Jeffrey D. Turano Request from: Office of Consumer Counsel Question: For each annual program on the Annual Projects tabs of Exhibit CLP-ADDITIONS-4, provide the unit cost applied in each year 2017 through 2025 – per pole, distribution transformer, switch or recloser, mile of overhead conductor, mile of underground cable, and meter – together with the source data and the budget-to-actual variance. Response: “Unit cost metrics” are not a reliable means of tracking these types of annual projects due to the scale and scope of the overall endeavor. The Company explained in its testimony, Exhibit CLPADDITIONS-1, beginning on page 25, the following process applicable to annual projects: A large volume of work occurs on the system on a daily basis associated with projects that are repetitive, numerous, and routine. These jobs are authorized in the aggregate, or by an annual program authorization. Individual review and authorization of each of these thousands of work orders is not necessary because the jobs are small in scope and highly repetitive in nature – therefore, the costs are highly consistent with the same cost drivers occurring over and over. Reviewing and approving each of these projects independently would require increased staffing levels for little or no marginal benefit, would unnecessarily slow the entire process down, and would negatively impact the Company’s ability to undertake routine jobs on a reasonable schedule to continue to provide safe and reliable service. In essence, annual programs represent non-discretionary operational programs required to efficiently operate the electric distribution system. Typically, these program budgets are set each year based on historical averages that may fluctuate depending on supply chain challenges driving up material prices (e.g., pre-capitalized transformers) and customer growth or retraction (e.g., new customer connection annual). The review and approval of annual programs has evolved. Prior to 2024, these programs were documented and supported by the Company’s capital book which is sent to the Board of Trustees in January/February of each year. This serves as documentation and approval of the capital plan. Prior to 2024, Eversource managed and balanced its capital plan across the Company and all other entities. Monthly workplans and financial reports sent to Operations and FinancePage 2
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-19 Date Issued September 21, 2026 OCC-789 Page 2 of 2 leadership served as the monitoring tool. Since the annuals were based on historical estimates, there were variances, both plus and minus, across the years. Following the RAM hearings at PURA in 2023 and a discussion on annual project documentation, beginning in 2024, the annual programs now have project authorization documents in addition to the Capital Book. Also, beginning in 2018, these annuals have been summarized in the annual RAM/ESI filing with an annual filing requirement to summarize budget versus actual variances greater than +/- 10%. To support the variances in the annuals from 2018-2025, the Company included these variance explanations in the project documentation support.
Text of OCC-791_Final.pdf
Extracted from the file · 1 page · 1,403 characters
As listed on the current system
Question(s) Answered 785, 786, 789, 791 (The Connecticut Light and Power Company) Date Filed: 10/05/2026