Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 934, 935, 937, 939, 940, 942, 943

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy9 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files9

Text of OCC-939_Final.pdf

Extracted from the file · 1 page · 1,688 characters

Text of OCC-939 Attachment 1.pdf

Extracted from the file · 1 page · 705 characters

Text of OCC-939 Attachment 1.xlsx

Extracted from the file

Text of OCC-940_Final.pdf

Extracted from the file · 1 page · 666 characters

Text of OCC-942_Final.pdf

Extracted from the file · 1 page · 645 characters

  1. Page 1

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-26 Date Issued October 05, 2026 OCC-943 Page 1 of 1 Date Filed: October 19, 2026 Witness: Jared A. Lawrence, Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (AMI – BRIDGE METERS) Please refer to Exhibit CLP-AMI-2, p. 10-11. a. Please clarify the exact number of bridge meters currently installed. b. Are bridge meters able to facilitate a time-varying/time of use rate? c. Must a customer have either a bridge meter or AMI meter to be served by a time-varying or time of use rate? Response: a. Eversource has 467,145 bridge meters currently installed in Connecticut as of this response. b. Bridge meters can facilitate Time of Use (TOU) rates, but the supporting billing system and interval data management system cannot support billing TOU customers using a bridge meter. Instead, the Company uses a different meter type to collect interval data and pass it along to the billing system for customers on TOU rates. If any customer with a bridge meter request to go on a TOU rate, a meter exchange is performed to support the different rate. c. Currently, a customer must have a dedicated interval-capable meter to support current forms of TOU rates. If AMI were approved in Connecticut, the company plans to set up appropriate system configurations (billing and meter data management) to allow the AMI meters to support TOU rates. The end goal would be to transition all existing TOU customers over to AMI meters once the system configurations are ready. In this AMI future, any customer that chooses to adopt a TOU rate will be able to do so without the need for a meter exchange.

As listed on the current system

Question(s) Answered 934, 935, 937, 939, 940, 942, 943 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 10/19/2026

This filing on the current system (opens in a new tab)