Interrogatory responses
Answers to questions 30, 33, 36, 37, 40
Files13
EOE-030_final.pdf
PDF · 85 KB · 1 pageText searchable
Download EOE-030_final.pdfRead the text of EOE-030_final.pdf
EOE-030 Attachment 1.pdf
PDF · 816 KB · 1 pageText searchable
Download EOE-030 Attachment 1.pdfRead the text of EOE-030 Attachment 1.pdf
EOE-030 Attachment 1.xlsx
Excel · 33 KBText searchable
Download EOE-030 Attachment 1.xlsxRead the text of EOE-030 Attachment 1.xlsx
EOE-033_final.pdf
PDF · 109 KB · 2 pagesText searchable
Download EOE-033_final.pdfRead the text of EOE-033_final.pdf
EOE-036 Attachment 1.pdf
PDF · 825 KB · 5 pagesText searchable
Download EOE-036 Attachment 1.pdfRead the text of EOE-036 Attachment 1.pdf
EOE-036_final.pdf
PDF · 83 KB · 1 pageText searchable
Download EOE-036_final.pdfRead the text of EOE-036_final.pdf
EOE-037_final.pdf
PDF · 97 KB · 1 pageText searchable
Download EOE-037_final.pdfRead the text of EOE-037_final.pdf
EOE-037 Attachment 1.pdf
PDF · 89 KB · 1 pageText searchable
Download EOE-037 Attachment 1.pdfRead the text of EOE-037 Attachment 1.pdf
EOE-037 Attachment 1.xlsx
Excel · 23 KBText searchable
Download EOE-037 Attachment 1.xlsxRead the text of EOE-037 Attachment 1.xlsx
EOE-040_final.pdf
PDF · 88 KB · 1 pageText searchable
Download EOE-040_final.pdfRead the text of EOE-040_final.pdf
EOE-040 Attachment 1.pdf
PDF · 2.4 MB · 108 pagesText searchable
Download EOE-040 Attachment 1.pdfRead the text of EOE-040 Attachment 1.pdf
EOE-040 Attachment 2.pdf
PDF · 2.4 MB · 108 pagesText searchable
Download EOE-040 Attachment 2.pdfRead the text of EOE-040 Attachment 2.pdf
EOE-040 Attachment 3.pdf
PDF · 12 MB · 328 pagesText searchable
Download EOE-040 Attachment 3.pdfRead the text of EOE-040 Attachment 3.pdf
Text of EOE-033_final.pdf
Extracted from the file · 2 pages · 2,411 characters
Text of EOE-036 Attachment 1.pdf
Extracted from the file · 5 pages · 10,251 characters
Text of EOE-036_final.pdf
Extracted from the file · 1 page · 605 characters
Text of EOE-037_final.pdf
Extracted from the file · 1 page · 1,678 characters
Text of EOE-037 Attachment 1.pdf
Extracted from the file · 1 page · 1,360 characters
Text of EOE-037 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of EOE-040_final.pdf
Extracted from the file · 1 page · 1,218 characters
Page 19 of 108
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 1 Page 19 of 108 Emergency Response Plan Electric System Operations - CT Table 2 - Event Level Matrix Full Time Employee/Equivalent Requirements Event Level Typical No. of Customers Out at Peak (FTEs at Onset/FTEs at Peak) (Note 1) Typical No. of Trouble Spots Line FTEs Service Onset | FTEs Peak Liaison (FTEs=Crews) Tree FTEs Damage Asmt FTEs (Note 2) Public Safety Specialist Comm. Liaison Large Customer Account FTEs Typical Restoration Duration Typical Global ETR Availability Timeframe 5 0% - 9% (<125K) <3000 540 | 1200 0 | 80 290 | 550 30 | 175 149 12 | 149 20 + 3 1-3 Days < 24 hours 4 10% - 29% (125K 380K) 1500 – 10,000 665 1,050 | 2,800 60 | 250 300 | 1,200 100 | 425 149 149 | 160 20 + 3 2-6 Days < 36 hours 3 30% - 49% (375K – 650K) 8,000 – 25,000 790 2,050| 6,000 120 | 500 900 | 2,500 275 | 1,225 149 160 | 185 20 + 6 5-10 Days < 48 hours 2 50% - 69% (625k – 870k) 15,000 – 48,000 1040 2,300| 6,000 240 | 640 1,000 | 2,500 625 | 1,225 149 185 | 215 20 + 6 8-21 Days < 72 hours 1 70% 100% (> 870k) > 35,000 1290 2,800 | 6,000 240 | 640 1,200 | 2,500 625 | 1,225 149 215 | 250 20 + 6 > 18 Days < 72 hours Note 1: FTEs at onset represents the minimum number of targeted FTEs assured prior to the event. Peak number of resources represents FTEs needed to restore high range number of trouble spots for each event type Note 2: Where Crews at Onset is expressed as a range, the lower number indicates the maximum Eversource can guarantee on the basis of internal employees and regular onsite contractors, and the higher number what Eversource will endeavor to achieve by securing additional contract and mutual assistance resources ahead of the storm. The base figure of 540 FTEs is the total complement of 310 crews accounting for typical unavailability because of sickness, FMLA, and disability Note 3: Assumes one tree crew for every two line crews Note 4: Per 48-hour Damage Assessment study Note 5: The Public Specialist role is not required to be activated for an Event Level 5. Based on the severity of the damage of an Event Level 5 event, this role may be activated EP-CT-ELEC-PLN-2000 19 of 108 Rev 5Page 20 of 108
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 1 Page 20 of 108 Emergency Response Plan Electric System Operations - CT 2.4.2 Event Level Overviews The Event Level is used for planning purposes to estimate the potential or actual size, scope, and complexity of the incident in order to disseminate and communicate the severity of the emergency to key stakeholders. When the severity and complexity of the emergency event are analyzed or more clearly understood, the Incident Commander is responsible for establishing or adjusting the Event Level as is appropriate. It is critical to maintain flexibility and scalability when establishing the appropriate response, organization, and scale of the response. Therefore, the Event Level does not necessarily stipulate a mandated response organization scale. Rather, the Event Level determination provides an expected scope of response activities and staffing requirements. The transition from one Event Level to another, either higher or lower, is accomplished solely at the discretion of the Incident Commander, based on analysis of the severity and complexity combined with recommendations of General and Command Staff, leadership, and other key organizational members. Once established or modified, the Event Level is communicated to all internal and external leaders and organizations currently engaged in or anticipated to be engaged in restoration or support activities, as soon as is practical. Typically, changes in the event level are communicated formally through the scheduled Briefing Sheets, published through Communications. Verbal communication should be made to stakeholders as soon as is practical, along with formal written briefings. Determining the level of an event helps determine the scope of the ICS deployment. Although not an exact science, reliance on the ELM and exercise of professional judgment will enable the IC to make a reasonable supposition. a. Level 5 Emergency Event A Level 5 event is classified as a local emergency that is expected to be resolved within one to three days and that may be readily addressed by company personnel or available contractors. In general, the impact on customers, the environment, and safety is minimal. Level 5 events generally are characterized by: o o o o o Ability to address the emergency in a timely manner Limited impact on customer outages (duration or number) Ability to restore service in a timely manner Lack of threat to broader public safety Limited impact on company operations or financial risk b. Level 4 Emergency Event A Level 4 event is classified as a local emergency event that has an appreciable impact on customers, the environment, and safety, and is expected to last between two and six days. Additional organizational and resource support is normally required. The initiating conditions for activation include: o o o o EP-CT-ELEC-PLN-2000 Broad customer or critical facility impact A threat to public safety Moderate impact on the environment Moderate impact on company operations or financial risk 20 of 108 Rev 5Page 21 of 108
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 1 Page 21 of 108 Emergency Response Plan Electric System Operations - CT c. Level 3 and 2 Emergency Events A Level 3 or 2 event is an emergency event that has a significant impact on customers, the environment, or safety and is expected to last between five and ten days or eight and twentyone days, respectively. Significant organizational support or multi-level agency and government involvement is normally required. The initiating conditions for activating the Level 3 or 2 emergency classifications include an event that causes: o o o o o o o o A system-wide event Significant potential adverse impact to public safety A major customer impact Ability to obtain needed resources based on the geographic breadth of the event Critical reputation damage to the Company Significant or ongoing environmental threat Multi-level agency and government involvement Triggers critical damage to the Company’s operations or financial risk d. Level 1 Emergency Event A Level 1 event is defined as an emergency that has a catastrophic impact on safety, customers, or the environment, and is expected to last more than eighteen days. Such events are generally system wide, and often affect neighboring utilities. A Level 1 event is one that: o o o o o o o 2.4.3 Causes a system wide outage event Poses a significant potential adverse impact to public safety Causes a major customer impact Results in a significant or ongoing environmental impact Triggers critical reputation damage to the Company Necessitates immediate multi-level agency and government involvement Triggers critical damage to the Company’s operations or financial risk Event Complexity Analysis The details of every event are unique. The Event Level Matrix is not designed to compartmentalize every event to a level of precision and accuracy with respect to the ultimate impact. The Event Level Matrix is designed to provide high-level estimates for typical events. Each event must be analyzed in its totality to determine how to categorize it and thus determine the appropriate response level. In addition to providing a guide to the scope and scale of the response, the categorization of an event is a way of communicating to employees and other stakeholders the magnitude of the event and the importance and level of the response. The recommended strategy is to err on the side of declaring a higher level event when it is a close determination. The IC may elect to declare an event a higher level event, even if all criteria are not met. 2.5 Eversource Energy Readiness Conditions Eversource has established a systematic approach to monitoring, assessing, and preparing for events that have the potential to impact one or more business units, employees, or customers. This approach includes activities from day-to-day hazard monitoring through full activation of all necessary personnel to support response and recovery for any type of emergency. This approach uses predefined Readiness Conditions to clearly communicate each operating company or business unit’s readiness posture, as delineated in Table 3 - Readiness Conditions below. EP-CT-ELEC-PLN-2000 21 of 108 Rev 5Page 22 of 108
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 1 Page 22 of 108 Emergency Response Plan Electric System Operations - CT 2.5.1 Readiness Condition - NORMAL General everyday operations are being performed. Business units are performing day-to-day routine operations and maintaining situational awareness by observing the changing and predicted weather conditions and the news for any event that could adversely affect operations. 2.5.2 Readiness Condition – MONITORING General everyday operations are being performed, but conditions are developing or exist (such as a potential heat wave, tropical storm, or nor’easter) that could present a potential risk to Eversource in the near future. Though the conditions currently pose no immediate threat, a heightened level of situational awareness (internal and external) and monitoring is implemented with more frequent communications taking place among decision makers. If it is determined that escalating emergency conditions are likely, a communication is sent to the Electric System organization and local authorities to update them about this condition. 2.5.3 Readiness Condition - WARNING General everyday operations are being performed, but conditions are developing or will soon exist that have a relatively high level of probability of impacting some or all of Eversource’s service area. Some day-to-day tasks and operations may be suspended or redirected. Mobilization of internal resources and partial acquisition/mobilization of external resources are considered and could begin. Incident Command and/or Emergency Operations Centers may be partially or fully activated. 2.5.4 Readiness Condition – EMERGENCY Emergency event conditions are imminent that will cause or have caused significant impact to the Electric System or one or more Eversource business units. Based on the potential Event Level, the following situations can occur: • • • • Activation of the ERP. Activation of the ICC. Activation of one or more regional Emergency Operations Centers (EOC). Mobilization of internal resources and acquisition/mobilization of external resources occur as needed. Table 3 - Readiness Conditions Readiness Conditions Situational awareness of resources Normal Monitoring Warning Emergency X X X X O O/X X Mobilization of resources Activation of Incident Management Teams Notification/Standby X Activation of Emergency Coordination Team Notification/Standby O/X Notification O Activation of Executive Oversight Group X – Likely 0 – Possible 2.6 Declaration of an Emergency Response Plan (ERP) Event An Emergency Event is a situation caused by the forces of nature, an accident, or an intentional act that constitutes a loss of electric service involving 10% or more of the Company’s total number of customers who are out of power for a period of 48 consecutive hours or more. See Attachment 2, Crosswalk Table of PURA Requirements on page 91. EP-CT-ELEC-PLN-2000 22 of 108 Rev 5Page 23 of 108
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 1 Page 23 of 108 Emergency Response Plan Electric System Operations - CT If an Emergency Event or other incident is likely and is expected to cause significant outages or damage to the distribution system, the Incident Commander or designee declares an ERP Event, indicating a formal initiation of the ERP. 2.7 Alert When a predicted event could lead to activation of the ERP at Level 3, 2, or 1, the Incident Commander provides Alert notification using emails and/or the Automated Response Call-Out System (ARCOS) to Command and General Staff in order to provide a common operating picture and to trigger pre-event preparedness activities. These Alerts may include briefing materials from news and/or meteorological services, or other related information. When the likelihood of the emergency event increases, the Incident Commander may also schedule daily planning meetings, conference calls, and/or briefings for Command and General staff, and request the Planning Section/Situation Unit to develop and disseminate daily Incident Action Plans or other documentation to guide preparedness objectives and actions. 2.8 Incident Command Center (ICC) Activation The ICC is a dedicated facility that is designed to assist management in taking prompt and effective actions to mitigate the consequences of an emergency. The Company maintains 24 hour coverage through the SOC until such time as an incident or emergency event warrants activation of the IMT organization. The ICC is activated consistent with the Event Level Matrix (Table 1 - Event Level Matrix Crew Requirements and Table 2 - Event Level Matrix Full Time Employee/Equivalent Requirements or as deemed necessary by the Emergency Preparedness (“EP”) organization and the Vice President of CT Electric System Operations, specific response procedure, or when an incident's size and complexity requires representation in the ICC by organizations to support expanded operations. The ICC, when activated as the ICP, operates around the clock until the event has terminated and the IC makes the determination to close it and return to normal operations. Transfer of command normally takes place at 12-hour intervals until the event is declared closed. The ICC supports the IC in preparation for and response to an emergency. Representatives from support organizations assemble in the ICC as necessary to coordinate response with the IC, Command Staff, and General Staff. The ICC operation is based on use of the ICS and is designed to function at a level consistent with the size and complexity of an event. Staffing of the ICC is dictated by the magnitude and complexity of the event. The level of activity, and the number and skills of staff required to carry out those activities vary. The activation of the ICC may occur when intelligence data indicates actual or potential incidents or events could escalate beyond the ability to manage the emergency event in the SOC. Activation of the ICC is initiated by telephone and/or email through the EP organization to affected personnel and assigned management staff. Selection of personnel and organizations required to support the operation are determined by the IC. The required support staff is alerted by the IC to report to the ICC to fulfill their assigned emergency roles and initiate staffing of their assigned functional areas. The following entities/organizations are also notified of an ICC activation: • Electric System Executive Management • System Operations Center/Transmission Operations Center • Electric System personnel • Connecticut Department of Emergency Management and Homeland Security (DEMHS), Connecticut Public Utilities Regulatory Authority (“PURA”), and state regulatory agencies EP-CT-ELEC-PLN-2000 23 of 108 Rev 5Page 24 of 108
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 1 Page 24 of 108 Emergency Response Plan Electric System Operations - CT 2.9 Notification 2.9.1 ERP Assignments • • • • • • 2.9.2 Personnel are identified and trained to fill key emergency response roles. A database is maintained by the EP organization to ensure the rosters for ERP roles are always filled. Systems are established to direct individuals during the declaration of an ERP event. Emergency response is a corporate responsibility and a responsibility of every Eversource employee. Preparedness is fundamental to the prompt and effective response to an emergency event. All employees have a continuing obligation to be prepared and to respond to emergency events as directed by management. As part of preparedness and responding to emergency events, the Company has established this ERP and associated documentation to ensure that appropriate resources and personnel are available and trained to support recovery and restoration operations during an emergency event. Employees are trained on and have been assigned to emergency roles that are activated when a major event occurs. For purposes of this ERP, an emergency response role is defined as a role or task that a person performs during emergency conditions that is different from their normal work activities. Other personnel may have an ERP role during an emergency event that does not change from their day-to-day responsibilities or job position. When an emergency event with the potential for severe impact is anticipated, the Company declares an ERP Event and all Electric System personnel are considered essential, unless otherwise excused. Employees are required to make themselves available for mobilization calls in the event they are needed to report to their assigned areas. The Company uses a variety of communication methods (pagers, email, voicemail, and, if necessary, public media) to broadcast this declaration as soon as the decision is made. Employees are expected to check these various communication channels with reasonable frequency to ensure they are aware when such a declaration occurs. Employees should listen for broadcast messages indicating that the Company is mobilizing for an event that has the potential to impact the service territory. All employees keep their contact information up-to-date in company directories. Employees unable to report to work due to home, family, or personal emergency conditions must immediately contact their supervisor. Policies addressing reporting to work, release from work, release from storm assignment, failure to report, and timekeeping during severe-impact storms and other emergencies can be found in the relevant company policy documentation. Stakeholder Pre-Event Notifications In some instances, it may be appropriate to initiate pre-event communications with key stakeholders prior to the activation of the IMT or staffing of the ICC. In such cases, communication is coordinated through the EP organization and the Communications Officer and should include an assessment of the potential risk and summary of preparedness activities. Communications for an anticipated Level 4 event or greater includes pre-event notifications with CT DEMHS, PURA, and municipal Emergency Management Directors or designees. EP-CT-ELEC-PLN-2000 24 of 108 Rev 5Page 25 of 108
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 1 Page 25 of 108 Emergency Response Plan Electric System Operations - CT 2.10 Operational Stages An emergency event may be segmented into phases or stages chronologically in order to assist in the coordination of actions and resources. At any given time, the organization may have different functions or geographic areas at different stages due to the nature of the event and the response. In general, operational stages include: • Pre-Event Preparedness • Mobilization and Initial Response • Sustained Actions • Demobilization and Post-Event Analysis and Reporting 2.10.1 Pre-Event Preparedness To ensure capability for immediate response to power outages caused by severe weather or other disruptions, several elements are set in place prior to an actual emergency. These elements may include, but are not limited to: • Notifications made to personnel concerning their assigned event reporting locations. • Contact lists updated for state and municipal officials. • Equipment needed for power restoration is identified and, if possible, pre-positioned at key points within the Company service territory. • Staging areas for management teams and work crews are established. • Contracts are set in place for outside line, service, and tree crews and other essential resources. • Mutual Aid Agreements are made through Edison Electric Institute (“EEI”) and membership in Regional Mutual Assistance Groups (“RMAG”), which for Eversource is the North Atlantic Mutual Aid Group (“NAMAG”). • Contract weather forecasting services are secured to provide weather forecasting service, with notification of any severe forecasts that can have potentially adverse impacts on the Electric System. • Communications materials are prepared in advance on key topics, points-of-contact, and basic facts explaining storm restoration activities and priorities. • The Customer Care organization is prepared to elevate to the emergency response level. • Assessment is made of the availability of the following resources: o o o o o EP-CT-ELEC-PLN-2000 Line Resources (including contractor and/or mutual aid) Vegetation Management Resources Service Company Resources Contact Center staff Support Resources (such as Damage Assessment Patrollers, Wire Guards, Logistics, and so on) 25 of 108 Rev 5Page 26 of 108
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 1 Page 26 of 108 Emergency Response Plan Electric System Operations - CT 2.10.2 Mobilization and Initial Response To ensure effective and efficient response to emergency events caused by severe weather or other disruptions, several elements are considered, including, but not limited to: • Establishment of ICS Structure • Activation of the ICC • IMT personnel notification • Assessment of resource needs and availability • Decentralization of system operations • Damage assessment planning • Municipal and other stakeholder outreach • Notification of appropriate state officials • Conference Calls There are four types of conference calls that may be conducted during an emergency event: o o o o Preparation Calls – The EP organization conducts a preparation call when the need to implement the preparations strategy is apparent or imminent. This call is held with the Command and General Staffs and other key personnel from support organizations. Incident Command Calls – The IC conducts periodic command calls to review progress on the IAP, refine or adjust the IAP based on changing conditions and current information, and to address tactical decisions, emergent issues, and requests for support. Emergency Coordination Calls – The ECT Calls are coordinated around other critical meetings in order for the team members to gather adequate situational awareness to be able to effectively report out at the meetings. Each Business Unit affected by the event outlines and discusses their event objectives for the current and next Operational Period. Following ECT calls, the ECT provides the EOG with status and advisory updates on a regular basis or immediately if conditions warrant. Section (Function) Calls – Each Section Chief, or designee, may hold function-specific calls (Operations, Planning, Logistics, Communications, and so on), as appropriate, to coordinate and update priorities, tasks, and deliverables to ensure consistency and alignment with the current guidance and Plan. The owner of each type of call should communicate the type of call to the affected audience in advance of the call when possible. Additionally, the Company participates in Eversource Energy system calls when an event impacts multiple operating companies or geographic areas. 2.10.3 Sustained Actions (Restoration) The term Sustained Actions generally covers the activities required to return the Electric System to normal configuration and operations. See Section 2.11, Service Restoration. 2.10.4 Demobilization and Post-Event Analysis and Reporting • EP-CT-ELEC-PLN-2000 Demobilization and post event analysis and reporting occur when restoration has been completed, all resources are demobilized; the ERP is deactivated; and normal operations resume. It is during this period that the Company gathers information, conducts incident reviews, analyzes data, develops after action reports, and identifies improvement to be implemented. 26 of 108 Rev 5Page 27 of 108
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 1 Page 27 of 108 Emergency Response Plan Electric System Operations - CT • • • 2.11 A post-storm critique or de-brief process is performed to capture strengths, weaknesses, and lessons learned. All groups involved in the restoration are requested to supply input during the process, including craft workers and all levels of field supervision. Administrative updates are made to contact lists and procedures to ensure readiness for the next emergency or event. Post-incident evaluations, commonly known as Lessons Learned and After-Action Reviews, contribute to continuous ERP improvements. Response activities are likely to improve when feedback recommendations are linked and incorporated into the Plan and associated support documentation. The EP organization ensures post-incident evaluations are performed following Homeland Security Exercise and Evaluation Program (“HSEEP”) guidelines and framework. Each area of the response organization is responsible for participating in post-incident performance reviews. These meetings identify response activities and opportunities for improvements. Participants and representatives from each business unit of the response organizations are invited to discuss lessons learned and to identify improvement opportunities. Improvement planning applies “SMART Corrective Actions,” which ensure that corrective actions that are developed are to be Specific, Measurable, Achievable, Relevant, and Time-bound. Once the actions are drafted, a Risk Assessment is performed on each to weigh variables such as impact, ease of implementations, and cost/benefit. These are then presented to the ECT for review and approval, identifying the appropriate sponsor and lead for the activity. The Company completes event and post-event reports in a timely manner. Post-event reports for any event that triggered the use of this ERP are submitted within 14 days in accordance with the decision in PURA Docket No. 86-11-18. After-Action Reports for Emergency Events only are completed and submitted within 60 days in accordance with the decision in PURA Docket No. 12-06-09. The After Action Review/Improvement Plan Procedure, EP-ALL-PRO-AAR-1000 and After Action Report/Improvement Plan, EP-ALL-FRM-AAR-1000, are completed within 60 days. Attachment 3, – Sample AAR Form shows an example of the After Action Review form. Service Restoration During significant events, there are different strategies that can be employed to efficiently utilize resources to ensure public safety and expedite the restoration of electric service to critical facilities and customers. The availability of several restoration strategies is necessary because a variety of factors, including: the severity of damage on the system, the geographic scope of the damage, the impact the event has on critical facilities and road accessibility and the need to utilize mutual aid crews, and influence the best way to respond to an emergency event. An overview of each of the general strategies is provided in Section 2.11.3, Restoration Strategies. It is important to note that the restoration period begins at the point that the Incident Commander has declared it “safe to proceed” for field resources to begin work. Once it is declared safe to proceed, the Company transitions to the “Emergency Period.” During this stage, the Company focuses on addressing imminent danger/life threatening condition (FPS 1) calls, Make Safe Blocked Roads (FPS 2), and high priority critical facilities. This period typically runs from the time the IC declares it safe to proceed to the issuance of the Global ETR. A Global ETR is an overall estimate of the number of days required during a widespread outage event to restore 99% of all Eversource customers served. A Town ETR is an overall estimate of the number of days required to restore 99% of all Eversource customers served in a given town during a town-wide outage event. An Event ETR is an estimate of the time required to restore customers associated with a specific event or trouble spot. EP-CT-ELEC-PLN-2000 27 of 108 Rev 5Page 28 of 108
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 1 Page 28 of 108 Emergency Response Plan Electric System Operations - CT 2.11.1 Response and Restoration Priority Guidelines Specific priorities and tactical objectives are guided by the availability of resources balanced with criticality, logistical factors, field conditions, and other exigencies of the event to optimize the overall response. There is no uniform rule regarding how to evaluate the priorities at any given moment because circumstances and priorities are constantly changing. A variety of factors and circumstances are considered when assigning work and may include, but are not limited to: the type and availability of necessary resources to make the repair, the proximity of available resources, the specific needs of the response (particularly as it relates to the need for specialized equipment), the potential consequences of delaying the restoration (that is, medical hardships or a sewage treatment plant with non-functional generator), the type and/or number of customers affected by the repair, and the time necessary to complete each specific restoration. Depending on actual circumstances, Eversource’s (Electric-CT) restoration response efforts may be prioritized along the following guidelines: • Public Safety Life Safety (Police & Fire Calls), including Level 1 E-911 calls and life threatening situations. • Electric Infrastructure Clearing blocked roads of electrical hazards as defined in the Connecticut ESF-12 Make Safe Protocol for Clearing Blocked Roads. • Critical Infrastructure Restoration of critical facilities as defined in the Connecticut ESF-12 Annex, as follows: o o Critical Facility – a building or structure where loss of utility services may interrupt functions considered essential for the delivery of vital services and the life safety of the community. They usually include emergency response facilities (fire, police, rescue, emergency operations centers), hospitals, licensed convalescent homes, facilities designated as emergency shelters, water supply and waste water treatment as provided by the CT Department of Health (“DPH”) and Department of Energy and Environmental Protection (“DEEP”), communications facilities (E911 and Public Safety Answering Points), and any other assets pre-identified or identified at the time of the emergency as needed to be of critical importance for the protection of the health and safety of the population. Other Utilities’ Critical Infrastructure – a list of specific facilities identified by other utilities (gas, water, telecommunications, and similar), maintained by the Utility Liaison (see Section 3.11.2d, Utility Liaison), and updated annually. Restoration of transmission lines, substations, and circuit backbones may be required before some critical facilities can be restored. • Transmission and Substations During events that include damage to the Transmission system, the IC activates the Transmission Section to address damage and restoration to the Transmission system. • Circuit Backbones Transmission system lines and substations and the re-energizing of distribution circuit backbone lines that are the main source of power to reach the distribution line lateral feeders. • Lateral Feeders Largest number of customers per resource. EP-CT-ELEC-PLN-2000 28 of 108 Rev 5
Text of EOE-040 Attachment 2.pdf
Extracted from the file · 108 pages · 299,821 characters
Text of EOE-040 Attachment 3.pdf
Extracted from the file · 328 pages · 663,868 characters
As listed on the current system
Question(s) Answered 30, 33, 36, 37, 40 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/14/2026