Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 30, 33, 36, 37, 40

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy13 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files13

Text of EOE-033_final.pdf

Extracted from the file · 2 pages · 2,411 characters

Text of EOE-036 Attachment 1.pdf

Extracted from the file · 5 pages · 10,251 characters

Text of EOE-036_final.pdf

Extracted from the file · 1 page · 605 characters

Text of EOE-037_final.pdf

Extracted from the file · 1 page · 1,678 characters

Text of EOE-037 Attachment 1.pdf

Extracted from the file · 1 page · 1,360 characters

Text of EOE-037 Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out

Text of EOE-040_final.pdf

Extracted from the file · 1 page · 1,218 characters

Text of EOE-040 Attachment 1.pdf

Extracted from the file · 108 pages · 301,257 characters

Text of EOE-040 Attachment 2.pdf

Extracted from the file · 108 pages · 299,821 characters

  1. Page 189 of 328

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 189 of 328 3. Training Requirements: Prerequisites • eLearning: Introduction to Emergency Preparedness at Eversource (EP-303) • eLearning: Introduction to the Incident Command System (EP-304) • eLearning: ARCOS and You (EP-103) • eLearning: Introduction to Business Continuity (EP-201) • eLearning: Wire Guard (EP-701P) Initial Training • Initial Wire Guard Instructor-Led Training (EP-701) • Initial EP OMS Training (EP-603) • Initial OMS Training – Coordinators (EP-603A) Refresher Training • 4. Required System / Drives Access: EP-ALL-EPJD-OP-14 eLearning: Wire Guard (EP-701R) Eversource N:\ Drive, SharePoint, Teams, OMS Rev 0 Page 3 of 3
  2. Page 190 of 328

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 190 of 328 EP-ALL-EPJD-OP-16 , Rev. 0 All Hazards Emergency Response Program Effective Date: 7/8/16 Approval Date: 7/8/16 Wire Guard Unit Leader EMERGENCY POSITION JOB DESCRIPTION INFORMATION A. Position Title: Wire Guard Unit Leader B. Reports To: Wire Guard Group Manager 1. Direct Reports: Wire Guard Coordinator Wire Guard Field Coordinator C. Position Duties and Responsibilities: The Wire Guard Unit Leader is responsible for managing and overseeing the response of Wire Guards to damage locations that require personnel to stand by potential electrical hazards D. Pre-Event Preparations: • Ensure knowledge and understanding of the Outage Management System (OMS) including the damage assessment and referral processes • Assess availability, activate, and deploy unit personnel as directed • Understand the provisions of the company union agreements as they are interpreted under emergency operations • Ensure technology and equipment at assigned work locations is tested and operational • Make notifications and activate personnel within unit: • Provide situational briefing on event to Wire Guard Group Manager and Wire Guard Coordinators • Develop shift schedules for the unit • Work with the Wire Guard Group Manager to secure external contractor resources • Contact Logistics Transportation Services Unit for required rental vehicles, if necessary • Develop and maintain an accurate work plan for wire guard jobs; ensure arrival and release times are accurately recorded in OMS • Coordinate with Restoration Management Teams to ensure that high priority wire downs have been responded to and have wire guard support if required • Ensure that Wire Guard Unit has schedule and system in place to provide relief and breaks to guards at damage locations • Ensure food and lodging requirements have been communicated to Logistics • Coordinate field support required for wire guard work as necessary • Ensure events are being referred to the appropriate resource group in the OMS work queue • Provide periodic updates to the Wire Guard Group Manager and participate in scheduled situational briefings and calls • Communicate to direct reports tactics specific to the unit as developed in the IAP • Direct relevant documentation to the Planning Section for disposition • Participate in After Action Review(s) E. F. Duties, Responsibilities, and Actions During an Emergency Event: Post- Emergency Event Responsibilities and Reports: Ensure you are using the current revision by verifying it against the controlled electronic copy located in the Emergency Preparedness & Business Continuity Documentation Database.
  3. Page 191 of 328

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 191 of 328 Personal Protective Equipment (PPE): G. Equipment Required: • N/A if in EOC or other office location Equipment and Supplies: • Phone • Computer Personal: • Appropriate clothing for weather conditions and any personal needs for multiple days away from home H. Position Work Location: Regional EOC or specific reporting location as directed I. Work Period: 8-16 hour work period per day J. Activation Notification: Call Out SUPPLEMENTAL JOB DESCRIPTION INFORMATION 1. Applicability: Electric ☒ 2. Primary Documentation: State Emergency Response Plan 3. Training Requirements: Gas ☐ Prerequisites • eLearning: Introduction to Emergency Preparedness at Eversource (EP-303) • eLearning: Introduction to the Incident Command System (EP-304) • eLearning: ARCOS and You (EP-103) • eLearning: Introduction to Business Continuity (EP-201) • eLearning: Wire Guard (EP-701P) Initial Training • Initial Wire Guard Instructor-Led Training (EP-701) • Initial EP OMS Training - Coordinators (EP-603A) Refresher Training • 4. Required System / Drives Access: EP-ALL-EPJD-OP-16 eLearning: Wire Guard (EP-701R) Eversource N:\ Drive, SharePoint, Teams, OMS Rev 0 Page 2 of 2
  4. Page 192 of 328

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 192 of 328 EP-ALL-EPJD-OP-17A , Rev. 0 All Hazards Emergency Response Program Effective Date: 8/18/2016 Approval Date: 8/18/2016 Wire Guard Field Coordinator EMERGENCY POSITION JOB DESCRIPTION INFORMATION A. Position Title: Wire Guard Field Coordinator B. Reports To: Wire Guard Unit Leader 1. Direct Reports: None C. Position Duties and Responsibilities: The Wire Guard Field Coordinator is responsible for coordinating and overseeing the response of Wire Guards dispatched to damage locations that require personnel to stand by potential electrical hazards. D. Pre-Event Preparations: • Ensure all required PPE is in order • Fully charge all portable devices • Ensure knowledge and understanding of the Outage Management System (OMS) including the damage assessment and referral processes • Assess availability, activate, and deploy unit personnel as directed • Understand the provisions of the company union agreements as they are interpreted under emergency operations • Provide situational briefing on the event • Work with the Wire Guard Coordinator to review external contractor resources available • Ensure Wire Guards dispatched to the field arrive in a timely manner • Resolve issues that arise at wire guard field locations • Provide periodic updates to the Wire Guard Coordinator and participate in scheduled situational briefings and calls • Ensure Wire Guards receive bio breaks, food and water, and relief at the end of their shift, consistent with the schedule • Coordinate with the Wire Guard Coordinator, as required • Direct relevant documentation to the Planning Section for disposition • Participate in After Action Review(s) E. F. Duties, Responsibilities, and Actions During an Emergency Event: Post- Emergency Event Responsibilities and Reports: Personal Protective Equipment (PPE): G. Equipment Required: • Reflective vest, safety shoes, hard hat Equipment and Supplies: • Phone • Computer Personal: • Appropriate clothing for weather conditions and any personal needs for multiple days away from home H. Position Work Location: Field location, as directed I. 8-16 hour work period per day Work Period: Ensure you are using the current revision by verifying it against the controlled electronic copy located in the Emergency Preparedness & Business Continuity Documentation Database.
  5. Page 193 of 328

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 193 of 328 J. Activation Notification: Call Out SUPPLEMENTAL JOB DESCRIPTION INFORMATION 1. Applicability: Electric ☒ 2. Primary Documentation: State Emergency Response Plan 3. Training Requirements: Gas ☐ Prerequisites • eLearning: Introduction to Emergency Preparedness at Eversource (EP-303) • eLearning: Introduction to the Incident Command System (EP-304) • eLearning: ARCOS and You (EP-103) • eLearning: Introduction to Business Continuity (EP-201) • eLearning: Wire Guard (EP-701P) Initial Training • Initial Wire Guard Instructor-Led Training (EP-701) Refresher Training • 4. Required System / Drives Access: EP-ALL-EPJD-OP-17A eLearning: Wire Guard (EP-701R) Eversource N:\ Drive Rev 0 Page 2 of 2
  6. Page 194 of 328

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 194 of 328 All Hazards Emergency Response Program Effective Date: 8/18/2016 EP-ALL-EPJD-OP-17 , Rev. 0 Approval Date: 8/18/2016 Wire Guard Coordinator EMERGENCY POSITION JOB DESCRIPTION INFORMATION A. Position Title: Wire Guard Coordinator B. Reports To: Wire Guard Unit Leader 1. Direct Reports: Wire Guard C. Position Duties and Responsibilities: The Wire Guard Coordinator is responsible to assign and dispatch Wire Guards to damage locations, within an assigned region, where downed wires have created a potential electrical hazard. D. Pre-Event Preparations: • Ensure knowledge and understanding of the Outage Management System (OMS) including the damage assessment and referral processes • Discuss availability with Wire Guard Unit Leader • Log in to OMS to validate credentials and ensure technology is up to date • Build Wire Guard crews in OMS • Verify availability of any needed Wire Guard Kits • Monitor priority calls and referrals in the OMS Work Agenda • Monitor work queue for referrals to Wire Guard • Assign Wire Guards to events in OMS • Coordinate with Wire Guard Field Coordinators and communicate with Wire Guards on assignments • Ensure necessary information for priority calls is captured, including when resource is assigned and arrives onsite, in event details • Add any relevant event comments in the OMS, based on field conditions reported by Wire Guards • Escalate any logistical issues to the Wire Guard Unit Leader • Coordinate with the Damage Assessment Coordinator to deploy Wire Guard resources as a result of conditions identified during damage assessment patrolling • Collaborate with the System Operator or Operations Coordinator when an emergency request is made for a Line Crew • Following the assignment and dispatch of a Wire Guard to an event, refer the event to the next appropriate group • Track all wire guard personnel within the respective area assigned • Create a rotational shift to allow breaks for people out in the field • Ensure that the guards provide public protection by directing public a safe distance away. • If DA has not been performed, document OMS remarks whether conductor is primary or secondary voltage, or if it is telecommunications wire • Forecast the next location • Direct relevant documentation to the Planning Section for disposition • Participate in After Action Review(s) E. F. Duties, Responsibilities, and Actions During an Emergency Event: Post- Emergency Event Responsibilities and Reports: Ensure you are using the current revision by verifying it against the controlled electronic copy located in the Emergency Preparedness & Business Continuity Documentation Database.
  7. Page 195 of 328

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 195 of 328 Personal Protective Equipment (PPE): G. Equipment Required: • N/A if in AWC Equipment and Supplies: • Phone • Computer Personal: • Appropriate clothing for weather conditions and any personal needs for multiple days away from home H. Position Work Location: Area Work Center I. Work Period: 8-16 hour work period per day J. Activation Notification: Call Out SUPPLEMENTAL JOB DESCRIPTION INFORMATION 1. Applicability: Electric ☒ 2. Primary Documentation: State Emergency Response Plan 3. Training Requirements: Gas ☐ Prerequisites • eLearning: Introduction to Emergency Preparedness at Eversource (EP-303) • eLearning: Introduction to the Incident Command System (EP-304) • eLearning: ARCOS and You (EP-103) • eLearning: Introduction to Business Continuity (EP-201) • eLearning: Wire Guard (EP-701P) Initial Training • Initial Wire Guard Instructor-Led Training (EP-701) • Initial EP OMS Training - Coordinators (EP-603A) Refresher Training • 4. Required System / Drives Access: EP-ALL-EPJD-OP-17 eLearning: Wire Guard (EP-701R) Eversource N:\ Drive Rev 0 Page 2 of 2
  8. Page 196 of 328

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 196 of 328 EP-ALL-EPJD-OP-18 , Rev. 0 All Hazards Emergency Response Program Effective Date: 7/26/16 Approval Date: 7/26/16 Wire Guard EMERGENCY POSITION JOB DESCRIPTION INFORMATION A. Position Title: Wire Guard B. Reports To: Wire Guard Coordinator 1. Direct Reports: None C. Position Duties and Responsibilities: Wire Guards are responsible for responding to public safety issues, as identified. Wire Guards are assigned and dispatched to damage locations, as directed by the Wire Guard Coordinator, where electric infrastructure has created a potential electrical hazard. D. Pre-Event Preparations: • Discuss availability with Wire Guard Coordinator • Check all personal protective equipment (PPE), supplies, and wire guard kit • Report to Wire Guard Coordinator for assignments • Report to assigned electric infrastructure location • Provide company presence at electrical infrastructure until made safe by qualified personnel • Warn the public of electrical hazards by use of cones, tape, and/or Wire Guard presence from a safe distance of 25 feet • Report unexpected field conditions back to Wire Guard Coordinator • Escalate any logistical issues to the Wire Guard Coordinator • Participate in After Action Review(s) E. F. Duties, Responsibilities, and Actions During an Emergency Event: Post- Emergency Event Responsibilities and Reports: Personal Protective Equipment (PPE): G. Equipment Required: • Reflective vest, safety shoes, hard hat Equipment and Supplies: • Wire Guard Kit • Phone Personal: • Appropriate clothing for weather conditions and any personal needs for multiple days away from home H. Position Work Location: Field Location I. Work Period: 8-16 hour work period per day J. Activation Notification: Call Out Ensure you are using the current revision by verifying it against the controlled electronic copy located in the Emergency Preparedness & Business Continuity Documentation Database.
  9. Page 197 of 328

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 197 of 328 SUPPLEMENTAL JOB DESCRIPTION INFORMATION 1. Applicability: Electric ☒ 2. Primary Documentation: State Emergency Response Plan 3. Training Requirements: Gas ☐ Prerequisites • eLearning: Introduction to Emergency Preparedness at Eversource (EP-303) • eLearning: Introduction to the Incident Command System (EP-304) • eLearning: ARCOS and You (EP-103) • eLearning: Introduction to Business Continuity (EP-201) • eLearning: Wire Guard (EP-701P) Initial Training • Initial Wire Guard Instructor-Led Training (EP-701) Refresher Training • 4. Required System / Drives Access: EP-ALL-EPJD-OP-18 eLearning: Wire Guard (EP-701R) Eversource N:\ Drive, Teams, SharePoint Rev 0 Page 2 of 2
  10. Page 198 of 328

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 198 of 328 EP-ALL-EPJD-OP-19 , Rev. 1 All Hazards Emergency Response Program Effective Date: 8/12/2022 Approval Date: 11/9/2016 Service Crew Group Manager EMERGENCY POSITION JOB DESCRIPTION INFORMATION A. Position Title: Service Crew Group Manager B. Reports To: Assistant Operations Section Chief 1. Direct Reports: Service Crew Unit Leaders C. Position Duties and Responsibilities: The Service Crew Group Manager oversees the management, coordination, and deployment of service crews to restore residential electrical services. D. Pre-Event Preparations: • Ensure the staffing rosters for Service Crew Branch positions are up to date and ready to be used • Understand the provisions of the company union agreements as they are interpreted under emergency operations • Deploy to ICC or specific reporting location as directed, report to the Assistant Operations Section Chief, and obtain a situational awareness and strategy briefing • Following activation of the Incident Management Team, activate the required Service Crew Branch personnel, develop staffing schedules, and provide initial staffing plans to the Operations and Logistics Section Chiefs • Conduct an initial briefing and routine update meetings and briefings with Service Crew Branch personnel • Inform the Assistant Operations Section Chief of additional Wire Guard Branch resource requirements • Ensure that access to storehouse service kits is available • Ensure the Service Crew Unit Leaders have developed and are maintaining an accurate work plan for house service work and that any updates in arrival, repair, or restoration times are being entered in the OMS • Ensure the Service Crew Unit Leader is coordinating with the applicable RMT Operations Coordinator if required for house service restoration work • Ensure Food and Lodging requirements have been communicated • Ensure service crews make every effort to notify customers, as appropriate, regarding followup work • Ensure temporary repairs that require known follow-up work by customer electricians and/ or municipal inspections are documented in the OMS before closing out the event • Ensure damage locations that involve telephone or third party equipment have been documented in the OMS before closing out the event • Ensure events are being referred to the appropriate resource group in the OMS work queue • Provide periodic status reports and updates to the Assistant Operations Section Chief • Develop resource release schedule and release crews as necessary to the Logistics Section for demobilization or redeployment • Ensure outside contractor time sheets are forwarded to appropriate financial personnel • Direct relevant documentation to the Planning Section for disposition • Participate in After Action Review(s) E. F. Duties, Responsibilities, and Actions During an Emergency Event: Post- Emergency Event Responsibilities and Reports: Ensure you are using the current revision by verifying it against the controlled electronic copy located in the Emergency Preparedness & Business Continuity Documentation Database.

As listed on the current system

Question(s) Answered 30, 33, 36, 37, 40 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/14/2026

This filing on the current system (opens in a new tab)