Interrogatory responses
Answers to questions 30, 33, 36, 37, 40
Files13
EOE-030_final.pdf
PDF · 85 KB · 1 pageText searchable
Download EOE-030_final.pdfRead the text of EOE-030_final.pdf
EOE-030 Attachment 1.pdf
PDF · 816 KB · 1 pageText searchable
Download EOE-030 Attachment 1.pdfRead the text of EOE-030 Attachment 1.pdf
EOE-030 Attachment 1.xlsx
Excel · 33 KBText searchable
Download EOE-030 Attachment 1.xlsxRead the text of EOE-030 Attachment 1.xlsx
EOE-033_final.pdf
PDF · 109 KB · 2 pagesText searchable
Download EOE-033_final.pdfRead the text of EOE-033_final.pdf
EOE-036 Attachment 1.pdf
PDF · 825 KB · 5 pagesText searchable
Download EOE-036 Attachment 1.pdfRead the text of EOE-036 Attachment 1.pdf
EOE-036_final.pdf
PDF · 83 KB · 1 pageText searchable
Download EOE-036_final.pdfRead the text of EOE-036_final.pdf
EOE-037_final.pdf
PDF · 97 KB · 1 pageText searchable
Download EOE-037_final.pdfRead the text of EOE-037_final.pdf
EOE-037 Attachment 1.pdf
PDF · 89 KB · 1 pageText searchable
Download EOE-037 Attachment 1.pdfRead the text of EOE-037 Attachment 1.pdf
EOE-037 Attachment 1.xlsx
Excel · 23 KBText searchable
Download EOE-037 Attachment 1.xlsxRead the text of EOE-037 Attachment 1.xlsx
EOE-040_final.pdf
PDF · 88 KB · 1 pageText searchable
Download EOE-040_final.pdfRead the text of EOE-040_final.pdf
EOE-040 Attachment 1.pdf
PDF · 2.4 MB · 108 pagesText searchable
Download EOE-040 Attachment 1.pdfRead the text of EOE-040 Attachment 1.pdf
EOE-040 Attachment 2.pdf
PDF · 2.4 MB · 108 pagesText searchable
Download EOE-040 Attachment 2.pdfRead the text of EOE-040 Attachment 2.pdf
EOE-040 Attachment 3.pdf
PDF · 12 MB · 328 pagesText searchable
Download EOE-040 Attachment 3.pdfRead the text of EOE-040 Attachment 3.pdf
Text of EOE-033_final.pdf
Extracted from the file · 2 pages · 2,411 characters
Text of EOE-036 Attachment 1.pdf
Extracted from the file · 5 pages · 10,251 characters
Text of EOE-036_final.pdf
Extracted from the file · 1 page · 605 characters
Text of EOE-037_final.pdf
Extracted from the file · 1 page · 1,678 characters
Text of EOE-037 Attachment 1.pdf
Extracted from the file · 1 page · 1,360 characters
Text of EOE-037 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of EOE-040_final.pdf
Extracted from the file · 1 page · 1,218 characters
Text of EOE-040 Attachment 1.pdf
Extracted from the file · 108 pages · 301,257 characters
Text of EOE-040 Attachment 2.pdf
Extracted from the file · 108 pages · 299,821 characters
Page 221 of 328
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 221 of 328 E. F. Duties, Responsibilities, and Actions During an Emergency Event: Post- Emergency Event Responsibilities and Reports: Ensure crew rosters have been provided to the Resource Acquisition/Tracking Branch Director and all crews have been properly received • Ensure crews are in OMS • • Monitor OMS for work requiring Pole Setting crews Document Pole Setting data in Pole Set Tracking Excel Sheet • Communicate and collaborate with RMT Operations Coordinator and Operations Coordination Support Specialist to ensure efficient use of crews and resources • • Assign work to crews in OMS Communicate with Digger Crew Lead in the field and provide assignment details • Refer events when work is completed by Pole Setting crews, if line or service resources are needed • Add event details and close tickets as work is completed • • Capture the number of Poles set by the pole owner Direct relevant documentation to the Planning Section for disposition • Participate in After Action Review(s) Equipment and Supplies: Phone Computer Personal: Appropriate clothing for weather conditions and any personal needs for multiple days away from home G. Equipment Required: 1. • Safety Requirements: Personal Protective Equipment (PPE): N/A – If in the EOC or AWC Reflective vest, safety shoes, hard hat H. Position Work Location: Area Work Center or specific field reporting location as directed I. Work Period: 8-16 hour work period per day J. Activation Notification: Call Out, Phone, Text, or Email 1. Applicability: Electric ☒ 2. Primary Documentation: State or Business Unit Emergency Response Plan Pole Setting Service Plan [insert document number here] Broken Pole Tracker Spreadsheet, available from the State or Business Unit EP Manager 3. Training Requirements: Initial Training SUPPLEMENTAL JOB DESCRIPTION INFORMATION Gas ☐ • • eLearning: Introduction to Emergency Preparedness at Eversource (EP-303) eLearning: Introduction to the Incident Command System (EP-304) • eLearning: ARCOS and You (EP-103) • • eLearning: Introduction to Business Continuity (EP-201) Annual Pole Setting Branch Training (EP 705) • OMS Pole Replacement Coordination (SOT-OMS-11) Refresher Training 4. Required System / Drives Access: EP-ALL-EPJD-OP-46 • Annual Pole Setting Branch Training (EP-705) • OMS Pole Replacement Coordination (SOT-OMS-11) Eversource N:\ Drive, SharePoint, Teams, OMS Rev 0 Page 2 of 2Page 222 of 328
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 222 of 328 All Hazards Emergency Response Program Effective Date: 9/23/2024 EP-ALL-EPJD-OP-47, Rev. 0 Approval Date: 9/23/2024 Digger Crew Lead EMERGENCY POSITION JOB DESCRIPTION INFORMATION A. Position Title: Digger Crew Lead B. Reports To: Pole Setting Coordinator 1. Direct Reports: Pole Setting Crew C. Position Duties and Responsibilities: 1. Physical Requirements: 2. Skills/Abilities: D. Pre-Event Preparations: The Digger Crew Lead coordinates the activities of the crews assigned to them. They communicate the restoration strategy to the crews and provide them with logistical details concerning food and lodging. They provide two-way communications regarding damage, resources, and materials needed with the Pole Setting Coordinator. Additionally, they contact the External Resource Field Unit Leader to locate ESOP-1000 APL (Authorized Persons List) qualified personnel for switching and tagging for assigned contractors. Driving Reaching above shoulder Lifting, pushing/pulling, carrying Bending ❑ Balancing Performing manual dexterity Ability to lift up to 20 lbs. Standing for long periods Exposed to extremes in temperature/humidity Excellent communication skills ❑ Excellent computer skills – Excel Strong analytical & problem-solving skills Ability to work outdoors for 12 hours ❑ Maintain ESOP-100 APL (Authorized Persons List) Qualification ❑ Proficiency with e Operations Mobile Application (OMA) application • Walking ❑ Stair climbing ❑ Prolonged hours sitting ❑ Working at heights ❑ Operating heavy equipment Kneeling Traveling Working with hazardous equipment ❑ ❑ Excellent interpersonal /phone skills ❑ Excellent time management skills ❑ Ability to prioritize & delegate as needed ❑ Proficiency with ARCOS application ❑ Proficiency with Outage Management System software ❑ Ensure all required Personal Protective Equipment is in order • Fully charge all portable devices • Coordinate/conduct required check-in activities for external crews Ensure you are using the current revision by verifying it against the controlled electronic copy located in the Emergency Preparedness Documentation Database.Page 223 of 328
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 223 of 328 E. F. Duties, Responsibilities, and Actions During an Emergency Event: Post- Emergency Event Responsibilities and Reports: G. Equipment Required: • Lead crews to work assignments and food/lodging accommodations • Contact designated ESOP-100 APL qualified personnel to coordinate switching and hold tagging clearances for contractors • Facilitate delivery of or deliver daily safety briefings to all contract Pole Setting crews under their supervision • Act as field liaison between Pole Setting contractors and Pole Setting Coordinator, should questions or issues arise • Ensure work assignments are provided to contractor crews • Ensure contractors are providing timely updates to be communicated to the Pole Setting Coordinator regarding work status (enroute, onsite, etc.) and scope of work regarding assigned outage/non outage events • Perform a general assessment of the next job assignment and work with the crew lead and Pole Setting Coordinator to arrange all necessary material, traffic control, etc, are arranged prior to crew arrival • Ensure that each crew has been provided required materials in coordination with material logistics and secure any additional required material as needed • Track contractor work and rest hours and ensure contractors properly complete time sheets, material lists, and equipment lists at the start and end of each shift; validate and authorize timesheets and ensure they are submitted per existing practice • Obtain primary maps if available from the appropriate Area Work Center (AWC) • Ensure Food and Lodging requirements for the unit have been communicated • Direct relevant documentation to the Planning Section for disposition • Ensure contractors return materials to designated locations • Turn in signed contractor time sheets and completed contractor evaluation forms to the Resource Acquisition/Tracking Group Manager • Participate in After Action Review(s) Equipment and Supplies: • Phone • Computer Personal: • 1. Safety Requirements: Appropriate clothing for weather conditions and any personal needs for multiple days away from home Personal Protective Equipment (PPE): • Reflective vest, safety shoes, hard hat, work gloves, safety glasses, FR Clothing as needed H. Position Work Location: Field I. Work Period: 8-16 hour work period per day J. Activation Notification: Call Out, Phone, Text, or Email EP-ALL-EPJD-OP-47 Rev 0 Page 2 of 3Page 224 of 328
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 224 of 328 SUPPLEMENTAL JOB DESCRIPTION INFORMATION 1. Applicability: Electric ☒ 2. Primary Documentation: State or Business Unit Emergency Response Plan Gas ☐ Pole Setting Process Description (EP-ALL-PD-1000-POLE) Broken Pole Tracker Spreadsheet, available from the State or Business Unit EP Manager 3. Training Requirements: Initial Training • eLearning: Introduction to Emergency Preparedness at Eversource (EP-303) • eLearning: Introduction to the Incident Command System (EP-304) • eLearning: ARCOS and You (EP-103) • eLearning: Introduction to Business Continuity (EP-201) • Annual Pole Setting Branch Training (EP-705) • External Resource Field Coordinator Training (EP-506) Refresher Training 4. Required System / Drives Access: EP-ALL-EPJD-OP-47 • Annual Pole Setting Branch Training (EP-705) • eLearning: External Resource Field Coordinator Refresher (EP-506R) Eversource N:\ Drive, SharePoint, Teams Rev 0 Page 3 of 3Page 225 of 328
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 225 of 328 EP-ALL-EPJD-OP-48, Rev. 0 All Hazards Emergency Response Program Effective Date: 9/23/2024 Approval Date: 9/23/2024 Dig Safe Coordinator EMERGENCY POSITION JOB DESCRIPTION INFORMATION A. Position Title: Dig Safe Coordinator B. Reports To: Pole Setting Branch Director 1. Direct Reports: Dig Safe Administrator C. Position Duties and Responsibilities: Ensures that the Dig Safe Administrators and/or Utility Liaisons execute their specific duties and responsibilities consistent with Pole Setting Service Plan. Reviews Pole Set related events and coordinates Dig Safe activities, including obtaining Dig Safe numbers for individual pole sets and records information in OMS and Pole Set Tracking Spreadsheet. Work with Dig Safe representatives to answer any questions or clarify any operations. 1. Physical Requirements: 2. Skills/Abilities: D. Pre-Event Preparations: E. F. Duties, Responsibilities, and Actions During an Emergency Event: Post- Emergency Event Responsibilities and Reports: Driving Reaching above shoulder Lifting, pushing/pulling, carrying Bending ❑ Balancing Performing manual dexterity Ability to lift up to 20 lbs. ❑ Standing for long periods Exposed to extremes in temperature/humidity Excellent communication skills Excellent computer skills – Excel Strong analytical & problem-solving skills Ability to work outdoors for 12 hours ❑ Maintain ESOP-100 APL (Authorized Persons List) Qualification ❑ Proficiency with e Operations Mobile Application (OMA) application Walking ❑ Stair climbing Prolonged hours sitting ❑ Working at heights ❑ Operating heavy equipment ❑ Kneeling Traveling ❑ Working with hazardous equipment Excellent interpersonal /phone skills Excellent time management skills Ability to prioritize & delegate as needed ❑ Proficiency with ARCOS application Proficiency with Outage Management System software • Discuss availability with the Pole Setting Branch Director • Ensure knowledge and understanding of the Outage Management System (OMS) including the assessment and referral process • Ensure access to event specific Pole Setting Tracker Spreadsheet • Ensure ID number for state specific Dig Safe is valid • Develop shift schedules for Dig Safe team • Ensure Food and Lodging requirements for the team have been communicated • Review OMS for POL referrals and contact Dig Safe (state-specific) for Dig Safe numbers • Ensure Pole Set Dig Safe data is entered into the Pole Setting Tracker Spreadsheet and OMS • Direct relevant documentation to the Pole Setting Branch Director for disposition • Ensure Dig Safe data has been entered for all relevant Pole Sets within OMS and the Pole Setting Tracker Spreadsheet • Participate in After Action Review(s) Ensure you are using the current revision by verifying it against the controlled electronic copy located in the Emergency Preparedness Documentation Database.Page 226 of 328
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 226 of 328 Equipment and Supplies: G. Equipment Required: • Phone • Computer Personal: • 1. Safety Requirements: Appropriate clothing for weather conditions and any personal needs for multiple days away from home Personal Protective Equipment (PPE): • N/A – If in an AWC • Reflective vest, safety shoes, hard hat H. Position Work Location: Area Work Center or specific reporting location as directed I. Work Period: 8-16 hour work period per day J. Activation Notification: Call Out, Phone, Text, or Email 1. Applicability: Electric ☒ 2. Primary Documentation: State or Business Unit Emergency Response Plan SUPPLEMENTAL JOB DESCRIPTION INFORMATION Gas ☐ Pole Setting Process Description (EP-ALL-PD-1000-POLE) Broken Pole Tracker Spreadsheet, available from the State or Business Unit EP Manager 3. Training Requirements: Initial Training • eLearning: Introduction to Emergency Preparedness at Eversource (EP-303) • eLearning: Introduction to the Incident Command System (EP-304) • eLearning: ARCOS and You (EP-103) • eLearning: Introduction to Business Continuity (EP-201) • Annual Pole Setting Branch Training (EP-705) • OMS Pole Replacement Coordination (SOT-OMS-11) Refresher Training 4. Required System / Drives Access: EP-ALL-EPJD-OP-48 • Annual Pole Setting Branch Training (EP-705) • OMS Pole Replacement Coordination (SOT-OMS-11) Eversource N:\ Drive, SharePoint, Teams, OMS Rev 0 Page 2 of 2Page 227 of 328
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 227 of 328 All Hazards Emergency Response Program Effective Date: 9/23/2024 EP-ALL-EPJD-OP-49, Rev. 0 Approval Date: 9/23/2024 Dig Safe Administrator EMERGENCY POSITION JOB DESCRIPTION INFORMATION A. Position Title: Dig Safe Administrator B. Reports To: Dig Safe Coordinator 1. Direct Reports: N/A C. Position Duties and Responsibilities: Reviews Pole Set related events and coordinates Dig Safe activities, including obtaining Dig Safe numbers for individual pole sets and records information in OMS and Pole Set Tracking Spreadsheet. Work with Dig Safe representatives to answer any questions or clarify any operations. 1. Physical Requirements: 2. Skills/Abilities: D. Pre-Event Preparations: E. F. Driving Reaching above shoulder Lifting, pushing/pulling, carrying Bending ❑ Balancing Performing manual dexterity Ability to lift up to 20 lbs. ❑ Standing for long periods Exposed to extremes in temperature/humidity Excellent communication skills Excellent computer skills – Excel Strong analytical & problem-solving skills Ability to work outdoors for 12 hours ❑ Maintain ESOP-100 APL (Authorized Persons List) Qualification ❑ Proficiency with e Operations Mobile Application (OMA) application Walking ❑ Stair climbing Prolonged hours sitting ❑ Working at heights ❑ Operating heavy equipment ❑ Kneeling Traveling ❑ Working with hazardous equipment Excellent interpersonal /phone skills Excellent time management skills Ability to prioritize & delegate as needed ❑ Proficiency with ARCOS application Proficiency with Outage Management System software • Discuss availability with the Dig Safe Coordinator • Ensure knowledge and understanding of the Outage Management System (OMS) including the assessment and referral process • Ensure access to event specific Pole Setting Tracker Spreadsheet • Ensure ID number for state specific Dig Safe is valid Duties, Responsibilities, and Actions During an Emergency Event: • Review OMS for POL referrals and contact Dig Safe (state-specific) for Dig Safe numbers • Ensure Pole Set Dig Safe data is entered into the Pole Setting Tracker Spreadsheet and OMS Post- Emergency Event Responsibilities and Reports: • Direct relevant documentation to the Dig Safe Coordinator for disposition • Ensure Dig Safe data has been entered for all relevant Pole Sets within OMS and the Pole Setting Tracker Spreadsheet • Participate in After Action Review(s) Ensure you are using the current revision by verifying it against the controlled electronic copy located in the Emergency Preparedness Documentation Database.Page 228 of 328
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 228 of 328 Equipment and Supplies: G. Equipment Required: • Phone • Computer Personal: • 1. Safety Requirements: Appropriate clothing for weather conditions and any personal needs for multiple days away from home Personal Protective Equipment (PPE): • N/A – If in an AWC • Reflective vest, safety shoes, hard hat H. Position Work Location: Area Work Center or specific reporting location as directed I. Work Period: 8-16 hour work period per day J. Activation Notification: Call Out, Phone, Text, or Email 1. Applicability: Electric ☒ 2. Primary Documentation: State or Business Unit Emergency Response Plan SUPPLEMENTAL JOB DESCRIPTION INFORMATION Gas ☐ Pole Setting Process Description (EP-ALL-PD-1000-POLE) Broken Pole Tracker Spreadsheet, available from the State or Business Unit EP Manager 3. Training Requirements: Initial Training • eLearning: Introduction to Emergency Preparedness at Eversource (EP-303) • eLearning: Introduction to the Incident Command System (EP-304) • eLearning: ARCOS and You (EP-103) • eLearning: Introduction to Business Continuity (EP-201) • Annual Pole Setting Branch Training (EP-705) • OMS Pole Replacement Coordination (SOT-OMS-11) • State-specific Dig Safe training Refresher Training 4. Required System / Drives Access: EP-ALL-EPJD-OP-49 • Annual Pole Setting Branch Training (EP-705) • OMS Pole Replacement Coordination (SOT-OMS-11) Eversource N:\ Drive, SharePoint, Teams, OMS Rev 0 Page 2 of 2Page 229 of 328
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 229 of 328 All Hazards Emergency Response Program Effective Date: 4/27/2016 EP-ALL-EPJD-PLN-01 , Rev. 0 Approval Date: 4/27/2016 Planning Section Chief EMERGENCY POSITION JOB DESCRIPTION INFORMATION A. Position Title: Planning Section Chief B. Reports To: Incident Commander 1. Direct Reports: • Planning Branch Director - Forecasting • Planning Branch Director - Tactical • Planning Branch Director – Transmission* (When the Transmission Section is activated, the Planning Branch Director – Transmission is not an active position and all branch members are moved to the Transmission Section) C. Position Duties and Responsibilities: The Planning Section Chief, in collaboration with the Incident Commander and other Command and General staff personnel, is responsible for developing and recommending the overall restoration strategy, including Estimated Times to Restoration (ETR) based on current resources available, damage assessment data, and current and forecasted weather conditions. Oversees the execution of the damage assessment process and the development of situation and resource status information. Collaborates with the Operations and Logistics Section Chiefs to determine resource requirements, and develops each operational period’s Incident Action Plan (IAP). Ensures the OMS ETRs and RTS Global Restoration Messaging are maintained, up to date and accurate, and ensures reporting to regulators is completed as required. D. Pre-Event Preparations: • Ensure the staffing rosters for the Planning Section positions are up to date and ready to be used • Ensure annual meetings are held by the Branch Directors, Group Managers, or Unit Leaders for employees whose primary emergency assignment differs from their Blue-Sky position. The meeting will: • Review the processes related to employees’ primary emergency assignment • Review employees’ completion of related training • Review tasks and tools associated with employees’ primary emergency assignment • Confirm that employees have been issued Personal Protective Equipment (PPE) required to complete their primary emergency assignment • Review the obligation of all employees to report to work when activated and that employees are aware of notification methods • Ensure availability of technology (that is, OUA, OMS, and so on) • Ensure technology users validate credentials and access • Deploy to the ICC when requested, report to the Incident Commander, and obtain a situational awareness and strategy briefing • Following activation of the Incident Management Team (IMT), activate the required Planning Branch Directors and other needed Planning Section personnel • Ensure each Planning Branch has a dedicated area to set up in the ICC, EOC, or nearby location and has all of the necessary equipment, supplies, and support • Conduct an initial briefing and routine update meetings and briefings with Planning Branch Directors • Assess potential system impact and possible outages based upon current system conditions as well as event predictions and historical system information Ensure you are using the current revision by verifying it against the controlled electronic copy located in the Emergency Preparedness & Business Continuity Documentation Database.Page 230 of 328
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-040 Attachment 3 Page 230 of 328 E. F. Duties, Responsibilities, and Actions During an Emergency Event: Post- Emergency Event Responsibilities and Reports: G. Equipment Required: • Ensure the ICC, EOC, and AWC IMT Rosters are developed, maintained, and up to date • Inform the Logistics Section of any potential need for additional resources • Instruct the Planning Branch Director - Forecasting to begin development of the first operational period IAP • Prepare routine updates, reports, and information to the Incident Commander and Command and General Staffs as required or requested • Conduct initial and follow-up Planning Section meetings or conference calls with Planning Section • Establish information requirements and reporting schedules for the various Planning Section Branches. • Oversee the damage assessment process, strategies, and the specific time constraints for the preparation of ETRs. Communicate this information as necessary, and monitor the overall progress • Oversee the collecting, analyzing, and managing of all emergency event status information, including damage assessment in OMA, outage calls in OMS, resource needs and allocation, and so on, and ensure it is compiled and displayed as necessary • Ensure accurate and timely regulatory reporting is completed in accordance with requirements • Collaborate with the Operations Section Chief and IC to develop appropriate ETRs • Collaborate with the Communications Officer and IC to determine the applicable Global Restoration Messaging to ensure consistency with the global ETRs, and ensure both are maintained and up to date • Oversee the allotment, movement within the IMTs geographic area of responsibility, and tracking of the on-boarded emergency response resources • Prepare regular reports and information for the IC as required or requested • Inform the Logistics Section of additional resource requirements (including the need for specialized resources) or when resources will soon become available for redeployment • Ensure that all damage assessment data is being entered and updated in OMA in a timely fashion • Ensure the development of the IAP in collaboration with the Incident Commander and the General and Command staffs • Recognize and report significant changes in incident status to the Incident Commander and provide situational awareness concerning other regional utilities, their performance, and any issues that could impact the company’s restoration efforts • Ensure that the positions within the Section execute their specific duties and responsibilities • Oversee the preparation of the Demobilization Plan to include developing a strategy for releasing external crews in the most cost effective manner and return the organization to normal business operations • Ensure that all forms and documentation are properly completed and provided to the Manager of Emergency Preparedness • Ensure outside contractor time sheets are forwarded to appropriate financial personnel • Participate in After Action Review(s) Personal Protective Equipment (PPE): • N/A if in the ICC or EOC Equipment and Supplies: • Phone • Computer Personal: • EP-ALL-EPJD-PLN-01 Appropriate clothing for weather conditions and any personal needs for multiple days away from home Rev 0 Page 2 of 3
As listed on the current system
Question(s) Answered 30, 33, 36, 37, 40 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/14/2026