Interrogatory responses
Answers to questions 379, 380, 381, 382, 383
Files11
EOE-379_Final.pdf
PDF · 181 KB · 5 pagesText searchable
Download EOE-379_Final.pdfRead the text of EOE-379_Final.pdf
EOE-379 Attachment 1.pdf
PDF · 1.2 MB · 2 pagesText searchable
Download EOE-379 Attachment 1.pdfRead the text of EOE-379 Attachment 1.pdf
EOE-380_Final.pdf
PDF · 96 KB · 3 pagesText searchable
Download EOE-380_Final.pdfRead the text of EOE-380_Final.pdf
EOE-381_Final.pdf
PDF · 89 KB · 2 pagesText searchable
Download EOE-381_Final.pdfRead the text of EOE-381_Final.pdf
EOE-382_Final.pdf
PDF · 86 KB · 1 pageText searchable
Download EOE-382_Final.pdfRead the text of EOE-382_Final.pdf
EOE-383_Final.pdf
PDF · 133 KB · 4 pagesText searchable
Download EOE-383_Final.pdfRead the text of EOE-383_Final.pdf
EOE-383 Attachment 1.pdf
PDF · 1.3 MB · 125 pagesText searchable
Download EOE-383 Attachment 1.pdfRead the text of EOE-383 Attachment 1.pdf
EOE-383 Attachment 2.pdf
PDF · 3.5 MB · 182 pagesText searchable
Download EOE-383 Attachment 2.pdfRead the text of EOE-383 Attachment 2.pdf
EOE-383 Attachment 3.pdf
PDF · 3.5 MB · 55 pagesText searchable
Download EOE-383 Attachment 3.pdfRead the text of EOE-383 Attachment 3.pdf
EOE-383 Attachment 4.pdf
PDF · 715 KB · 2 pagesText searchable
Download EOE-383 Attachment 4.pdfRead the text of EOE-383 Attachment 4.pdf
EOE-383 Attachment 5.pdf
PDF · 730 KB · 7 pagesText searchable
Download EOE-383 Attachment 5.pdfRead the text of EOE-383 Attachment 5.pdf
Text of EOE-381_Final.pdf
Extracted from the file · 2 pages · 3,490 characters
Text of EOE-382_Final.pdf
Extracted from the file · 1 page · 2,648 characters
Text of EOE-383_Final.pdf
Extracted from the file · 4 pages · 10,383 characters
Text of EOE-383 Attachment 1.pdf
Extracted from the file · 125 pages · 401,903 characters
Page 25 of 182
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 13, 2026 EOE-383 Attachment 2 Page 25 of 182 Report on the Response of CL&P and UI to Storms in August and October 2011 13. The process for determining the estimated total restoration time at the district level – as described in 3.7.1 of the District Plan – is a commendable approach and confirms CL&P’s awareness of the need of this information for all stakeholders. It is commendable that the CL&P plan has a process to seek to determine for each district the overall restoration time, and the approach in the formula is logical. In the absence of a predictive model, this is a good tool. This advanced information can be used not only to determine needed resources, but also to set realistic expectations among stakeholders. 14. The CL&P ERP wording dealing with training and drills is weak, and does not provide the adequate structure to effectively train and drill responders. (See Recommendation 11.) The approach of the CL&P ERP is to push the responsibility for training and drills down to the district level. This does not foster the type of consistent, coordinated training and drills as needed. The wording on drills allows too much leeway for the district and division to skip drills. 15. A significant portion of the CL&P response team has not “bought in” to the new ERP. This results in an inconsistent restoration response because of selective or no use of the plan. (See Recommendation 12.) Comments from several members of the CL&P response team indicate that there are responders who think the plan is deficient, and either do not use it or use it selectively. 3. II-CL&P-1 Recommendations Re-format the EPOPS document into smaller segments to enhance the use of this information during emergencies. By re-formatting this large document into smaller books no larger than the basic plan, CL&P will make it easier as a reference for responders, and therefore encourage its use. II-CL&P-2 Add language to the “Authority and Policies” subsection of the Basic plan that clearly describes and reaffirms top management’s ultimate authority for and complete support of the response to major outages. Prior to the statement on the delegation of the authority for the emergency response, it should be clearly set forth in the Plan (and communicated to all members of the CL&P response team) that the top management of NU and CL&P take ultimate responsibility and provide their enthusiastic support to the CL&P storm leaders. II-CL&P-3 Include language in Sections 2.2 and 2.3 (safety and environment) that emphasizes a more proactive approach in these areas. Safety and Environmental should include some language concerning proactive training and preventive measures. April 16, 2012 The Liberty Consulting Group page 22Page 26 of 182
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 13, 2026 EOE-383 Attachment 2 Page 26 of 182 Report on the Response of CL&P and UI to Storms in August and October 2011 II-CL&P-4 Add language to the ERP to provide guidance for activation/escalation “from the top down” when the situation calls for it. Language to the effect that in the event of a pending major outage event where there is some advance notice, the ICS activation will begin with the Area Command. II-CL&P-5 Change Level V in the Classification of Service Outage Events chart (Section 5.2, page 22, Basic Plan) to cover all outages of 80,000 customers and above. The chart inadvertently skips the range of customer outages from 80,000 to 100,000. By starting Level V at 80,000, CL&P will be committing to a maximum response from both CL&P and NU at even a lower trigger, which is appropriate. II-CL&P-6 Add a segment on clean-up activities in Subsections 6 – Post Incident Activities – in the Basic Plan, and Subsections 5 – Post Storm Activities – in the District and Division Plans. This includes post-storm patrols, repairs of quick-fixes on line facilities, additional trimming, and removal of broken trees and limbs that pose an outage hazard. II-CL&P-7 Place the responsibility for all drills and training with the EMG, and reword Section 2, District Plan, 3.13 to strengthen the process and place more emphasis on the training process. The concept of pushing the responsibility down to the lowest level of the organization is contrary to the usual practice in utilities. As written, the CL&P plan does not place an adequate stress on training and drills. II-CL&P-8 Provide specific guidance 3.2, Conference Calls, Section 2, District Plan, as to the frequency and time of day for conference calls. It will be necessary to change the time and frequency of the calls during the response effort as situations dictate. However, as part of the planning process, the optimum times and frequency of these calls should be determined and written into the plan. II-CL&P-9 Modify the wording in 3.3, District Decentralization, Section 2, District Plan to provide for the activation of Area and Division Command anytime decentralization is being considered. The plan covering district decentralization should confirm Area and Division Command activation. There should not be any need to qualify the instructions to cover “when the Area Command is activated,” and “when the Division command is activated.” II-CL&P-10 Strengthen the wording in 3.4, Activation and Staffing of the District Incident Command Post, Section 2, District Plan. The wording should April 16, 2012 The Liberty Consulting Group page 23Page 27 of 182
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 13, 2026 EOE-383 Attachment 2 Page 27 of 182 Report on the Response of CL&P and UI to Storms in August and October 2011 provide specific guidelines for triggers of when it should use certain organizational structures. Wording such as “the District Commander shall use the Section Chiefs assigned to the respective District ICS to assist in the implementation” should be used. (CL&P may choose to establish a specific threshold for this move.) Another suggested wording change is, “The span of control for any ICS supervisor shall be limited to 5, unless there is a specific need to exceed that slightly.” II-CL&P-11 Revise the ERP to provide for centralized training and drills, and firm up the wording concerning number of required drills. There should be more direct involvement of a centralized training group. In addition, the language permitting fewer drills is troubling. While certainly actual storm response will interrupt the drill schedule, this wording could promote a less than aggressive approach to drills. II-CL&P-12 Address aggressively the concerns of the response team concerning the usefulness and use of the plan. Top management should make visits to all districts and division commands to discuss with responders how the plan can become more useful, and clearly communicate that management expects all to follow the plan. C. UI 1. Form and Contents The emergency plan for United Illuminating (UI) is the Emergency Preparedness Plan (EPP). The plan of record during the response to Hurricane Irene and the October snowstorm was the plan filed with PURA in 2006. UI planned to file a revised plan with PURA in June 2011, but requested an extension until it could incorporate the recommendations of a consultant contracted for early in 2011. As a result, the revision was in progress at the time of the two storms, and there was considerable confusion as to the actual plan that UI used during the response to these storms. Responses from UI to audit requests and in interviews reflected that confusion. For example, when requested to provide the organization chart for the storm response team, UI responded with a chart dated October 26, 2011, and made reference to sections in the 2011 plan. However, in the revision history of the plan filed December 1, 2011, UI noted that on October 31, 2011, it sent the final draft for review by the UI team, and that the final update of the plan was not complete until November 21, 2011.28 In another response, UI confirmed that the plan of record was the 2006 plan, and that it did not file the 2011 plan with PURA until after the response to both storms.29 During the course of Liberty’s inquiries, UI referred to organization charts dated July 6, August 23, and October 26. 28 29 Response to audit request Liberty - 003 Response to audit request AG -169 April 16, 2012 The Liberty Consulting Group page 24Page 28 of 182
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 13, 2026 EOE-383 Attachment 2 Page 28 of 182 Report on the Response of CL&P and UI to Storms in August and October 2011 Based on information received by Liberty, it appears that UI used an interim plan, which provided guidelines in some areas. In other areas, the 2006 plan was still in use. Liberty was unable to find documentation of the specific plan that UI used. Based on its review, Liberty concluded that the 2006 plan was very outdated and afforded little if any guidance in 2011. UI appears to have made some significant changes for the better in the newly revised 2011 plan. However, because it was not complete, it would be misleading for Liberty to provide comments on that plan as if UI used it during the 2011 storms. Based on the above, Liberty is unable to make any meaningful comments on the UI emergency plan used in 2011, other than to say that UI’s failure to have a definite plan for the responders was a confusing and negative factor in their response efforts. 2. Training, Drills, and Use of EPP For the reasons stated above (no definitive documented emergency plan in use), it can only be concluded that drills and training leading up to these two storms would have been nonproductive. UI covers training and drills in the 2011 plan. Liberty is unable also to comment on the use of the plan during the 2011 storms, as there was no definitive plan. 3. Conclusions 1. UI’s failure to have a revised emergency plan in place at the time of the impact of the two storms created confusion and affected the restoration response. (See Recommendation 1) Based on information received by Liberty, it appears that UI used an interim plan, which provided guidelines in some areas. In other areas, the 2006 plan was still in use. Liberty was unable to find documentation of the specific plan that UI used. Liberty concluded that the 2006 plan was very outdated and afforded little if any guidance in 2011. UI appears to have made some significant changes for the better in the newly revised 2011 plan. 4. Recommendations II-UI-1 Initiate a process for regular updates to the EPP, document the updates, and conduct the necessary training to be sure all responders are familiar with the plan. Even though UI is not required to file a revised plan more frequently than 5 years, the changes made in the 2006 plan were significant and should have been made earlier rather than wait until required by PURA. April 16, 2012 The Liberty Consulting Group page 25Page 29 of 182
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 13, 2026 EOE-383 Attachment 2 Page 29 of 182 Report on the Response of CL&P and UI to Storms in August and October 2011 Appendix II-1 – Script for CL&P Tabletop Drill held August 25, 2011 Scenario A tropical depression has formed in the Eastern Atlantic, just south of The Cape Verde Islands. The storm formed on Day 1 and has begun moving to the west-northwest. Over the next several days, the storm will become better organized and gain in strength. Day T-4 The storm has reached hurricane strength and is located several hundred miles to the east of the Leeward Islands. It is expected when the storm approaches these islands it will make a sharp turn to the northwest and pass to the north of all the islands in the Caribbean. EOC will continue to monitor and send out the weather forecast. Initial Actions Area Work Center What are your plans and/or preparations? Day T-3 & T2 The storm has reached its peak as a Category 4 storm. Sustained winds are now at 143 mph with higher gusts. The storm is located several hundred miles to the east of Florida. As the storm is approaching the east coast, it will begin to curve northward passing over the Outer Banks of North Carolina. The storm is expected to decrease in strength to a Category 2 storm as it approaches Connecticut. Additional Actions Area Work Center What are your preparations? Day T-1 The storm is tracking along the east coast, over the water which is allowing the storm to maintain its strength. As a typical hurricane along the east coast, it is beginning to accelerate as it passes North Carolina. The storm is expected to make landfall on Long Island, New York in the early morning hours of Day 5, tomorrow. The storm will continue north through Connecticut (tracking up the Connecticut River Valley) and is expected to make landfall in CT somewhere between 5:00 AM and 10:00 AM as a Category 2 with winds forecasted between 96 to 110 MPH, and continue to track towards Massachusetts, central New Hampshire and western Maine. Ongoing Actions Area Work Center What are your plans and/or preparations? Day T 0 April 16, 2012 The Liberty Consulting Group page 26Page 30 of 182
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 13, 2026 EOE-383 Attachment 2 Page 30 of 182 Report on the Response of CL&P and UI to Storms in August and October 2011 At 0600 hours, Connecticut is experiencing gale force winds and outages are occurring on the coast line. At 0800 hours, Connecticut is being hit with a Category 2 hurricane with sustained winds of 110 mph and gusts to 120 mph accompanied by tropical rains (up to 4 inches is expected). Outages are occurring all over Connecticut and Massachusetts. As of the last hourly report, Connecticut is reporting 400,000 people out of power and the damage to the electrical system is heavy. Many roads are closed due to fallen trees and flooding. Also many bridges have been damaged. Massachusetts is reporting 80 mph winds in Springfield and heavy rains. Outage reports are 100,000 people without power. The storm moved quickly across Connecticut. At 1000 hours, the eye of the storm has crossed the Massachusetts border and is still headed north on its path towards New Hampshire. New Hampshire is currently experiencing gale force winds. We are currently reporting over 406,000 customers out in CT. with over 1,800 trouble locations. There is a total of 91 E911 calls: • Level 1 – 130 calls • Level 2 – 90 calls • Level 3 – 310 calls Necessary Actions/Steps: April 16, 2012 The Liberty Consulting Group page 27Page 31 of 182
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 13, 2026 EOE-383 Attachment 2 Page 31 of 182 Report on the Response of CL&P and UI to Storms in August and October 2011 III. Routine Maintenance and Inspections A. CL&P 1. Vegetation Management a. Background (1) Requirement to Trim Electric utilities operate their systems along many miles of right-of-way (ROW) and deeded easements. In order to provide safe and consistent electric service, the utilities must keep these lines clear of contact with tree branches and limbs. Trimming trees is an essential part of maintaining a reliable system for any electric utility. Vegetation Management (VM) programs refer to a utility’s tree trimming practices and ROW policies. The National Electric Safety Code (NESC) states: “Vegetation that may damage ungrounded supply conductors should be pruned or removed. Vegetation management should be performed as experience has shown to be necessary.” These rules are broad and vague; however, the NESC’s goal is mainly safety. From a utility perspective, circuits normally de-energize from vegetation contact before circuit damage. Therefore trimming trees is primarily important for maintaining reliable service. The main public safety issues are homeowners contacting lines while cutting their own trees or homeowners cutting trees that fall and damage the lines. In addition to trimming trees and ROW to prevent line contact, maintaining a corridor of trimmed trees also provides access to the power line for inspections and maintenance. There are two mechanisms where a tree can cause a power outage. The most common of these is electrical. Vegetation contacts and bridges the circuit between an energized conductor and a grounded conductor. The voltage in the circuit creates and builds up a carbon path across the vegetation. It eventually arcs over and trips a circuit fuse or other protective device to cause an outage. The second means is mechanical. A heavy branch or tree falls and breaks lines, poles, and equipment. (2) Storm Impacts on Vegetation Listed below are some definitions of common vegetation concerns due to storms. Fall Zone – This is the area including the roadside clearance zone and extending from the conductors out a distance to where an uprooted tree could strike the conductor and cause an outage. Danger Tree – Any tree located in the fall zone that is tall enough to potentially contact the energized conductors if it were to fall. The total number of danger trees on the CL&P system is in the millions.30 30 Interview #65, 2/23/12, Sean Redding April 16, 2012 The Liberty Consulting Group page 28Page 32 of 182
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 13, 2026 EOE-383 Attachment 2 Page 32 of 182 Report on the Response of CL&P and UI to Storms in August and October 2011 Hazard Tree – Any danger tree that is dead or, after evaluation using the Handbook of Hazard Tree Evaluation for Utility Arborists, rates as a moderate or high hazard. Another term for these is risk trees. CL&P estimates the number of hazard trees on its system is 340,000.31 Clearance Zone – This is the area to the side, above and below the energized conductors that is trimmed during the trim cycles. Overhang – Any limbs projecting above the defined clearance zone are overhanging limbs. Overhead Hazards – These are dead, dying, diseased, insect infected or structurally weak branches that overhang or are located to the side of the clearance zone, including those which could break at weak points and strike conductors when swinging down in an arc. The main storm impacts to utility circuits from vegetation are: • Falling Hazard Trees – these could occur during both minor and major storms. • Breaking Overhead Hazards • Falling Danger Trees – these occur mainly during major storms when the tree is uprooted and falls or leans into the line. Irene caused over 15,600 distribution trouble spots (estimated damage locations resulting in outages) and the snowstorm caused over 25,500. Trees caused the vast majority of these trouble spots. Connecticut has one of the most dense tree canopies in the United States (# 1 in the U.S. for Woodland/Urban Interface tree density). Connecticut’s tree profile also revealed trees with larger circumferences than average. In addition to the normal cyclic trimming of clearance zones, key success factors in reducing tree-caused storm outages are the identification and removal of hazard trees and overhead hazards; and the reduction of overhanging limbs. (3) General Vegetation Trim Rights When utility facilities are not located on the public right-of-way or on property owned by the utility itself, it must obtain an easement, license, lease, or other applicable property right in order to trim. The real estate documents granting such use of private property set forth the rights the utility has to use, operate, and maintain its facilities on that property, including any right to deal with vegetation management issues. Such vegetation management rights generally fall within three areas: the cleared width, danger or hazard tree rights, and access rights to the right-of-way. In the cleared width, the property documents dictate the rights to trim and remove vegetation that is incompatible with the safe and reliable operation of the electric system. Danger or hazard tree rights allow the utility to trim or remove trees that are an imminent threat to the electric system from outside the cleared width. Access rights allow the utility to travel across land outside of the cleared width to access the private right-of-way and the electric facilities. Within the cleared width of the right-of-way, the property rights obtained by the utility do not generally restrict the amount of tree trimming or removal that it can perform. Outside of the cleared width, if the utility does not have hazard tree rights, it generally cannot trim or remove trees without the consent of the property owner. Even where there are risk tree rights, the utility 31 Audit Request OCC-118 April 16, 2012 The Liberty Consulting Group page 29Page 33 of 182
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 13, 2026 EOE-383 Attachment 2 Page 33 of 182 Report on the Response of CL&P and UI to Storms in August and October 2011 may not have the authority to remove every tree that has the potential to fall into the electric facilities. For roadside distribution line-clearance tree work (i.e., facilities that are located on the public right-of-way), the utility’s rights to trim and remove trees are limited by the Connecticut General Statutes and the rights they convey to tree owners. The utility and its contractors are restricted by statutes that require a tree warden permit (CGS 23-65(f)), adjoining property owner consent (CGS 16-234), a state DOT permit (CGS 13a-140), and notification of the chief elected official for removal of any tree with a diameter greater than 18 inches along state highways (CGS 13a140). These statutes allow the state, towns, and individual property owners to restrict the nature and amount of tree work that the company performs from outright refusing to allow any tree work at all or limiting the extent of permitted tree work. b. Program Overview - Distribution CL&P has 16,961 miles of overhead primary voltage distribution lines that it must trim. About 46 percent of the conductors are insulated types such as tree wire, aerial cable, or spacer cable. The remaining 54 percent is bare conductor. The company’s existing tree trimming plan is to trim these lines on an average 5-year cycle. CL&P estimates that is needs to trim 180 trees per mile.32 The Public Utilities Regulatory Authority established and authorized funding for the 5year cycle in its decisions in Docket Nos. 07-07-01 and 09-12-05. The budget established by these dockets was $21.5M for 2011. The company’s tree trimming plan for 2011 is to complete 3,393 miles of trimming. This will be the fourth consecutive year in which CL&P has trimmed approximately 20 percent of the total miles. By the end of 2012, it will achieve the 5-year cycle average across the entire system. The trimming plan is not a true cyclic program. Arborists choose the circuits for trimming each year based on two conditions, SAIDI (the system average interruption duration index) and years since last trimmed. As a result, CL&P has not trimmed some circuits for seven to eight years. CL&P developed the 2011 plan in the fall of 2010. CL&P’s vegetation management team of arborists developed the annual work scope to get a balance of miles and tree crews spread throughout the service territory. There is a documented process for the circuit selection method. They calculate a weighted ranking of each circuit. They use the last three years of SAIDI nonstorm performance and the last three years of SAIDI storm performance. After this ranking, they exclude circuits trimmed within the last three years. Typically, in June of each year, they make the selection based on the worst performers and the years since the last trim. Once CL&P’s vegetation management team finalizes the schedule, it meets with the contractors to plan the timing of the work completion over 12 months. Throughout the year, the team meets with the contractors each month to review schedule completion and contractor performance. 32 Interview #65, 2/23/12 April 16, 2012 The Liberty Consulting Group page 30Page 34 of 182
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 13, 2026 EOE-383 Attachment 2 Page 34 of 182 Report on the Response of CL&P and UI to Storms in August and October 2011 Since 1987, the standard trim specification has been to trim 8 feet to the conductor side, 15 feet above, and 10 feet under (8 x 15 x 10). All hazard trees up to and including 16 inches DBH (diameter at breast height) within 8 feet of the outermost conductor are identified and removed. Northeast Utilities (NU) must approve the removal of any tree greater than 16 inches DBH. NU will provide specific instructions in each case depending on whether others are sharing the cost or disposing of the tree parts. In addition to the standard trim specification, CL&P has an Enhanced Tree Trimming (ETT) specification used for selected circuits. The ETT trim specification depends on whether the circuit portion is a backbone or a lateral.33 The table below shows the ETT specifications. The side clearances are the same as the standard specification. The ETT specifications are more aggressive in the removal of overhanging limbs, overhead hazards, and hazard trees. Side Clearance Overhead Clearance Backbone 8 feet of side clearance or to the previously established tree line. Trim and remove all overhanging limbs. Remove all overhead hazards within reach of a (70 foot) lift unit. Lateral 8 feet of side clearance or to the previously established tree line. Trim to provide a minimum of 20 feet of overhead clearance and remove all overhead hazards within reach of a standard (55 foot) lift unit. Hazard Trees Inspect, evaluate, and eliminate all hazardous trees within the fall zone by pruning or removal. Inspect, evaluate, and eliminate all hazardous trees within the fall zone by pruning or removal. CL&P cleared all of the roadside backbone circuit portions (3,694 miles) to ETT specifications.34 It cleared about 3,124 miles of lateral circuit portions to ETT specifications, but has not cleared 9,667 miles of lateral to ETT specifications. 33 Backbone – A three phase section of line starting at a substation and extending to the first fused device or single/double phase reclosing device. About 22 percent of the circuit miles are backbone. Lateral – A section of primary voltage line extending from the end of backbone to a secondary or service wire. About 78 percent of the circuit miles are laterals. 34 Audit Request OCC-109 April 16, 2012 The Liberty Consulting Group page 31
Text of EOE-383 Attachment 3.pdf
Extracted from the file · 55 pages · 132,814 characters
Text of EOE-383 Attachment 4.pdf
Extracted from the file · 2 pages · 4,635 characters
Text of EOE-383 Attachment 5.pdf
Extracted from the file · 7 pages · 11,175 characters
As listed on the current system
Question(s) Answered 379, 380, 381, 382, 383 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 10/27/2026