Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Compliance Filing

Compliance Filing, Order No. No

Compliance filingFiled by Eversource Energy24 files
Part of docket 26-08-07Open
  • Electric
Innovative Energy Solutions Program Cycle 5

Files24

Search terms highlighted
Eversource rate increase is on 5 pages across 2 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
2 pages match
Words on different pages

Text of ES-Attachment 2b 2026 TDRP-Appendix 8.pdf

Extracted from the file · 23 pages · 37,559 characters

Text of ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES-Attachment 3.pdf

Extracted from the file · 1 page · 7,205 characters

Text of ES-Attachment 3.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES-Attachment 4.pdf

Extracted from the file · 44 pages · 108,591 characters

Text of ES-Attachment 4.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES-Attachment 5.pdf

Extracted from the file · 30 pages · 79,263 characters

Words on different pagesRead the text of ES-Attachment 5.pdf

Text of ES-Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of ES-Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Words on different pages
  1. Page 11 of 176

    03/31/2026 Docket No. 86-12-03 2021 2022 2023 2024 Four-Year Average (’21 – ’24) 2025 SAIFI IEEE-1366 0.51 0.49 0.62 0.62 0.56 0.51 SAIDI IEEE-1366 44 46 50 49 47 39 CAIDI IEEE-1366 86 95 80 80 85 77 MAIFI IEEE-1366 0.94 Table IV.2 As shown on Table IV.1, the CAIDI performance in 2025 was 76 minutes. The CAIDI goal as derived from the SAIDI and SAIFI merger performance commitment goals is 103 minutes. One driver for the CAIDI performance in 2025 is due to the continued proactive reliability–focused Company practices. These practices include: troubleshooter staffing and schedule modification, as warranted, the deployment of additional isolating devices in order to improve partial restoration capabilities, and system dispatcher training in the utilization of fault data analytics in order to assist in the determination of fault location. Table IV.3 below presents CAIDI year-by-year targets for the next four years. These targets are calculated based on the Company’s performance commitments for SAIDI and SAIFI. CAIDI Target (Minutes) 2026 103 2027 103 2028 103 2029 103 Table IV.3 As can be seen in Appendix 5, “Reliability Performance against Goals,” UI continues to provide its customers with highly reliable electric service. All indices indicate that UI's customers are generally receiving adequate service, which meets or exceeds the levels set by the Company's Reliability Criteria. Per the Department’s definition of “major storms”, there were six “major storms” during 2025 as defined by Docket 86-12-03 (see Appendix 7: Excluded Storm Summary). In compliance with PURA’s Final Decision dated May 15, 2019 on Docket Number 18-05-13: PURA 2018 Reliability Report to the General Assembly on Electric Distribution Company System 11
  2. Page 12 of 176

    03/31/2026 Docket No. 86-12-03 Reliability, Order 1 states: “Each year, the EDC shall update the Table on its Response to Interrogatory EL-4 and file it with its annual TDRP Report”. The updated major storm information noted in Order 1 is provided in Appendix 9. Charts IV-1.1: System Average Interruption Duration Index (2021-2025) and IV-1.2: System Average Interruption Frequency Index (2021-2025) are shown on the next two pages. These charts illustrate calendar year 2025 and previous years' SAIDI and SAIFI indices categorized by outage type. Coupled with Appendix 5, “Reliability Performance against Goals,” 2025 reliability performance can be "benchmarked" against past performance. 12
  3. Page 13 of 176

    03/31/2026 Docket No. 86-12-03 Chart IV-1.1 System Average Interruption Duration Index (2021–2025) 13
  4. Page 14 of 176

    03/31/2026 Docket No. 86-12-03 Chart IV-1.2 System Average Interruption Frequency Index (2021–2025) 14
  5. Page 15 of 176

    03/31/2026 Docket No. 86-12-03 Chart IV-1.3 Customer Average Interruption Duration Index (2021–2025) 15
  6. Page 16 of 176

    03/31/2026 Docket No. 86-12-03 Chart IV-1.4 Customers Experiencing Multiple Interruptions (2025) 16
  7. Page 17 of 176

    03/31/2026 Docket No. 86-12-03 Chart IV-1.5 Customers Experiencing Long Interruption Duration (2025) 17
  8. Page 18 of 176

    03/31/2026 Docket No. 86-12-03 Per Docket No. 17-12-03RE08, UI is to include reliability metrics calculated with and without the inclusion of major storms and planned outages in its annual report. Table IV.4 below provides the SAIDI, SAIFI, CAIDI, MAIFI, CEMI, CELID, CEMM, and CEMSMI values for 2025. The four customer-centric metrics are further segmented into tranches of three or more, five or more, seven or more, and nine or more. SAIDI SAIFI CAIDI MAIFI CEMI-3 CEMI-5 CEMI-7 CEMI-9 CELID-3 CELID-5 CELID-7 CELID-9 CEMM-3 CEMM-5 CEMM-7 CEMM-9 CEMSMI-3 CEMSMI-5 CEMSMI-7 CEMSMI-9 Excluding Major Storm & Planned 35 0.46 76 0.88 0.0239 0.0005 0.0000 0.0000 0.0304 0.0100 0.0051 0.0022 0.0957 0.0184 0.0061 0.0037 0.1680 0.0417 0.0103 0.0050 Excluding Major Storm 36 0.48 76 0.89 0.0268 0.0007 0.0000 0.0000 0.0318 0.0107 0.0056 0.0023 0.0961 0.0186 0.0061 0.0037 0.1736 0.0435 0.0109 0.0051 Including Major Storm 72 0.64 113 1.22 0.0465 0.0027 0.0003 0.0000 0.0875 0.0409 0.0249 0.0146 0.1605 0.0352 0.0112 0.0057 0.2668 0.0843 0.0241 0.0103 All Outages 73 0.66 111 1.22 0.0507 0.0030 0.0004 0.0000 0.0889 0.0416 0.0254 0.0147 0.1609 0.0355 0.0113 0.0057 0.2723 0.0866 0.0253 0.0105 Table IV.4 Per Docket No. 24-08-09, UI is to report on the number of CEMI-3, CEMI-5, CEMI-7, CELID-3, CELID-6, CELID-9, and CELID-12 customers as a ratio of total customers served consistent with the IEEE-1366 standard. The CEMI and CELID data are to both include and exclude major storms. Both the IEEE-1366 (Major Event Day) and General Statutes § 16-245y(a) (major storms, scheduled interruptions, power supply outages, and customer-caused) methodologies are to be utilized. Additionally, the CEMI and CELID data is to be broken out by outages on the secondary and primary distribution system, both separately and as a whole. A four-year rolling average of CEMI and CELID interruptions from the four years preceding the year in question is also to be included. Table IV.5 below lists a breakdown of primary vs. secondary classification based on outage voltage descriptions. 18
  9. Page 19 of 176

    03/31/2026 Docket No. 86-12-03 Voltage Description Secondary Service Net 120/208V Net 277/480V 2.4kV 4.16kV 13.8kV 115kV 345kV Sub 2.4/4kV Sub 13.8kV Primary / Secondary Secondary Secondary Secondary Secondary Primary Primary Primary Primary Primary Primary Primary Table IV.5 Table IV.6 below gives the CEMI and CELID breakdown for 2025 and four-year rolling average per Docket No. 24-08-09. All-In Primary / Secondary Primary Secondary Both KPI 2025 CEMI-3 CEMI-5 CEMI-7 CELID-3 CELID-6 CELID-9 CELID-12 CEMI-3 CEMI-5 CEMI-7 CELID-3 CELID-6 CELID-9 CELID-12 CEMI-3 CEMI-5 CEMI-7 CELID-3 CELID-6 CELID-9 CELID-12 0.0480 0.0027 0.0004 0.0866 0.0299 0.0139 0.0087 0.0001 0.0000 0.0000 0.0026 0.0011 0.0008 0.0004 0.0507 0.0030 0.0004 0.0889 0.0310 0.0147 0.0091 IEEE-1366 Average (’21 – ‘24) 0.0513 0.0083 0.0005 0.0756 0.0271 0.0136 0.0096 0.0001 0.0000 0.0000 0.0021 0.0007 0.0004 0.0002 0.0539 0.0086 0.0006 0.0773 0.0278 0.0140 0.0098 2025 0.0239 0.0014 0.0002 0.0338 0.0086 0.0021 0.0009 0.0000 0.0000 0.0000 0.0014 0.0005 0.0003 0.0001 0.0255 0.0015 0.0003 0.0352 0.0090 0.0024 0.0010 Table IV.6 IEEE-1366 removes the following: • Scheduled Outages • Major Event Days 19 Average (’21 – ‘24) 0.0366 0.0035 0.0004 0.0523 0.0132 0.0048 0.0018 0.0000 0.0000 0.0000 0.0015 0.0006 0.0003 0.0001 0.0378 0.0036 0.0004 0.0536 0.0138 0.0051 0.0019 Non-Excluded 2025 0.0228 0.0004 0.0000 0.0291 0.0072 0.0020 0.0008 0.0000 0.0000 0.0000 0.0012 0.0003 0.0002 0.0001 0.0238 0.0005 0.0000 0.0303 0.0075 0.0022 0.0009 Average (’21 – ‘24) 0.0322 0.0029 0.0004 0.0444 0.0109 0.0033 0.0010 0.0000 0.0000 0.0000 0.0013 0.0005 0.0003 0.0001 0.0331 0.0030 0.0004 0.0456 0.0114 0.0036 0.0012
  10. Page 20 of 176

    03/31/2026 Docket No. 86-12-03 Non-Excluded removes the following: • Outages caused by Power Supply or Transmission Problems external to UI • Scheduled Outages • Outages caused by Customer equipment connected to UI lines • Major Storms Per Docket No. 21-05-15RE02, the revised proposal for the Equitable Reliability PIM is comprised of the following four sub-metrics: (1) CEMI 5; (2) Percent of repeat CEMI 5 customers; (3) CELID 6; (4) Percent of repeat CELID 6 customers. The CEMI 5 and CELID 6 sub-metrics shall be calculated as directed in Order Nos. 1 and 2, respectively, of the 2024 Reliability and Resilience Decision. The percent of repeat CEMI 5 customers shall be calculated as the number of CEMI 5 customers who appear on the CEMI 5 lists for both the current year and the prior year divided by the total number of CEMI 5 customers in the current year. The percent of repeat CELID 6 customers shall be calculated as the number of CELID 6 customers who appear on the CELID 6 lists for both the current year and the prior year divided by the total number of CELID 6 customers in the current year. Table IV.7 below lists the CEMI-5 and CELID-6 breakdown of current and repeating customers. Method All-In IEEE-1366 NonExcluded Year CEMI-5 Repeat CEMI-5 CELID-6 Repeat CELID-6 Average 2025 2024 2023 2022 2021 2020 2025 2024 2023 2022 2021 2020 2025 2024 2023 2022 2021 2020 0.0030 0.0122 0.0150 0.0044 0.0027 0.0229 0.0015 0.0038 0.0059 0.0031 0.0014 0.0064 0.0005 0.0037 0.0058 0.0013 0.0012 0.0055 0.3365 0.3873 0.0245 0.1039 0.1665 0.0667 0.6277 0.2681 0.0534 0.1382 0.0000 0.0042 0.6000 0.2719 0.0305 0.0131 0.0000 0.0005 0.0310 0.0605 0.0163 0.0171 0.0173 0.3550 0.0090 0.0092 0.0153 0.0164 0.0141 0.0127 0.0075 0.0090 0.0109 0.0141 0.0118 0.0087 0.2323 0.0564 0.0666 0.0374 0.4848 0.1095 0.0500 0.0628 0.0709 0.0348 0.0629 0.0237 0.0588 0.0615 0.0456 0.0243 0.0372 0.0071 0.1507 0.1291 0.0306 0.0407 0.1678 0.1385 0.1720 0.0860 0.0364 0.0481 0.0196 0.0118 0.1667 0.0865 0.0232 0.0132 0.0125 0.0055 Table IV.7 IEEE-1366 removes the following: • Scheduled Outages • Major Event Days 20

Text of UI-Attachment 2.pdf

Extracted from the file · 108 pages · 171,300 characters

Text of UI-Attachment 3.pdf

Extracted from the file · 79 pages · 105,929 characters

Words on different pagesRead the text of UI-Attachment 3.pdf

Text of UI-Attachment 4a.pdf

Extracted from the file · 60 pages · 136,974 characters

Text of UI-Attachment 4b.pdf

Extracted from the file · 32 pages · 73,024 characters

Text of UI-Attachment 5.pdf

Extracted from the file · 10 pages · 12,154 characters

Words on different pagesRead the text of UI-Attachment 5.pdf

Text of UI-Attachment 6.pdf

Extracted from the file · 29 pages · 55,721 characters

Words on different pagesRead the text of UI-Attachment 6.pdf

Text of UI-Attachment 7.pdf

Extracted from the file · 33 pages · 83,950 characters

Words on different pagesRead the text of UI-Attachment 7.pdf

Text of UI-Attachment 9.pdf

Extracted from the file · 14 pages · 33,843 characters

Words on different pagesRead the text of UI-Attachment 9.pdf

Text of UI-Attachment 11.pdf

Extracted from the file · 4 pages · 13,890 characters

Text of UI-Attachment 12.pdf

Extracted from the file · 36 pages, 2 without text · 106,019 characters

As listed on the current system

Compliance Filings, 10/01/2026 [26-08-07] Order No.No 4 in docket 17-12-03RE05 / Eversource Energy /

This filing on the current system (opens in a new tab)