Compliance Filing
Compliance Filing, Order No. No
Files24
Joint Cover Letter re Compliance No 4.pdf
PDF · 143 KB · 2 pagesText searchable
Download Joint Cover Letter re Compliance No 4.pdfRead the text of Joint Cover Letter re Compliance No 4.pdf
26-08-07 Comp Order 4.pdf
PDF · 589 KB · 29 pagesText searchable
Download 26-08-07 Comp Order 4.pdfRead the text of 26-08-07 Comp Order 4.pdf
ES-Attachment 2a 2026 TDRP-Appendix 8.pdf
PDF · 380 KB · 23 pagesText searchable
Download ES-Attachment 2a 2026 TDRP-Appendix 8.pdfRead the text of ES-Attachment 2a 2026 TDRP-Appendix 8.pdf
ES-Attachment 2b 2026 TDRP-Appendix 8.pdf
PDF · 379 KB · 23 pagesText searchable
Download ES-Attachment 2b 2026 TDRP-Appendix 8.pdfRead the text of ES-Attachment 2b 2026 TDRP-Appendix 8.pdf
ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx
Excel · 68 KBText searchable
Download ES-Attachment 2b 2026 TDRP-Appendix 8.xlsxRead the text of ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx
ES-Attachment 3.pdf
PDF · 40 KB · 1 pageText searchable
Download ES-Attachment 3.pdfRead the text of ES-Attachment 3.pdf
ES-Attachment 3.xlsx
Excel · 25 KBText searchable
Download ES-Attachment 3.xlsxRead the text of ES-Attachment 3.xlsx
ES-Attachment 4.pdf
PDF · 239 KB · 44 pagesText searchable
Download ES-Attachment 4.pdfRead the text of ES-Attachment 4.pdf
ES-Attachment 4.xlsx
Excel · 67 KBText searchable
Download ES-Attachment 4.xlsxRead the text of ES-Attachment 4.xlsx
ES-Attachment 5.pdf
PDF · 650 KB · 30 pagesText searchable
Download ES-Attachment 5.pdfRead the text of ES-Attachment 5.pdf
ES-Attachment 1.xlsx
Excel · 5.2 MBText searchable
Download ES-Attachment 1.xlsxRead the text of ES-Attachment 1.xlsx
ES-Attachment 1.xlsx
Excel · 5.2 MBText searchable
Download ES-Attachment 1.xlsxRead the text of ES-Attachment 1.xlsx
UI-Attachment 1.pdf
PDF · 4.4 MB · 176 pagesText searchable
Download UI-Attachment 1.pdfRead the text of UI-Attachment 1.pdf
UI-Attachment 2.pdf
PDF · 1.9 MB · 108 pagesText searchable
Download UI-Attachment 2.pdfRead the text of UI-Attachment 2.pdf
UI-Attachment 3.pdf
PDF · 8.6 MB · 79 pagesText searchable
Download UI-Attachment 3.pdfRead the text of UI-Attachment 3.pdf
UI-Attachment 4a.pdf
PDF · 854 KB · 60 pagesText searchable
Download UI-Attachment 4a.pdfRead the text of UI-Attachment 4a.pdf
UI-Attachment 4b.pdf
PDF · 120 KB · 32 pagesText searchable
Download UI-Attachment 4b.pdfRead the text of UI-Attachment 4b.pdf
UI-Attachment 5.pdf
PDF · 96 KB · 10 pagesText searchable
Download UI-Attachment 5.pdfRead the text of UI-Attachment 5.pdf
UI-Attachment 6.pdf
PDF · 465 KB · 29 pagesText searchable
Download UI-Attachment 6.pdfRead the text of UI-Attachment 6.pdf
UI-Attachment 7.pdf
PDF · 288 KB · 33 pagesText searchable
Download UI-Attachment 7.pdfRead the text of UI-Attachment 7.pdf
UI-Attachment 9.pdf
PDF · 694 KB · 14 pagesText searchable
Download UI-Attachment 9.pdfRead the text of UI-Attachment 9.pdf
UI-Attachment 11.pdf
PDF · 162 KB · 4 pagesText searchable
Download UI-Attachment 11.pdfRead the text of UI-Attachment 11.pdf
UI-Attachment 12.pdf
PDF · 652 KB · 36 pagesText searchable
Download UI-Attachment 12.pdfRead the text of UI-Attachment 12.pdf
Text of ES-Attachment 2b 2026 TDRP-Appendix 8.pdf
Extracted from the file · 23 pages · 37,559 characters
Text of ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ES-Attachment 3.pdf
Extracted from the file · 1 page · 7,205 characters
Text of ES-Attachment 3.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ES-Attachment 4.pdf
Extracted from the file · 44 pages · 108,591 characters
Text of ES-Attachment 4.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ES-Attachment 5.pdf
Extracted from the file · 30 pages · 79,263 characters
Text of ES-Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Text of ES-Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Page 117 of 176
03/31/2026 Docket No. 86-12-03 The United Illuminating Company SAIDI/SAIFI Worst 4% of All Circuits Ranked by Average SAIFI Average Rank Circuit SAIFI 1 2 3 4 5 6 7 8 9 10 11 12 512 2683 2688 2684 1862 2801 2673 2550 2624 2685 1694 1531 3.00 2.06 2.04 2.04 1.93 1.68 1.51 1.46 1.38 1.33 1.33 1.28 SAIDI (Mins) 229 207 287 224 194 158 147 133 126 96 81 87 July 2024 – June 2025 SAIDI SAIFI (Mins) 3.23 213 0.20 27 0.85 121 2.11 242 1.00 142 1.17 52 1.25 142 1.04 86 0.48 52 2.32 141 2.55 112 1.50 144 2024 Flag Y N N Y N N Y N N Y Y Y July 2023 – June 2024 SAIDI SAIFI (Mins) 5.90 509 1.68 172 4.34 468 0.77 120 4.00 303 2.21 217 2.80 251 1.61 137 2.62 150 0.48 45 0.19 7 0.44 28 July 2022 – June 2023 SAIDI SAIFI (Mins) 1.47 47 3.74 278 0.89 110 1.57 166 0.00 0 1.60 181 0.63 113 3.17 305 0.14 10 1.38 128 1.04 102 1.18 102 July 2021 – June 2022 SAIDI SAIFI (Mins) 1.39 145 2.61 349 2.09 447 3.70 369 2.71 329 1.75 180 1.35 82 0.03 3 2.26 291 1.14 68 1.53 104 2.01 75 * Circuits are flagged as Y if they reached or exceeded 250% of the systemwide SAIFI value for the period of July 2024 to July 2025 Excludes the following: • Outages caused by Power Supply or Transmission Problems external to UI • Scheduled outages • Outages caused by Customer Equipment connected to UI lines • Major Storms 117Page 118 of 176
03/31/2026 Docket No. 86-12-03 f. SAIDI/SAIFI Worst 4% of All Circuits (2025 Calendar Year) The United Illuminating Company SAIDI/SAIFI Worst 4% of All Circuits Ranked by Average SAIDI Rank Circuit 1 2 3 4 5 6 7 1862 Average SAIDI SAIFI (Mins) 353 2.18 2025 SAIDI SAIFI (Mins) 780 2.00 2025 Y 2024 SAIDI SAIFI (Mins) 115 1.00 2023 SAIDI SAIFI (Mins) 188 3.00 2022 SAIDI SAIFI (Mins) 329 2.71 2688 512 2684 2506 2683 2682 324 228 181 180 177 169 2.53 2.97 1.58 0.25 1.70 1.20 391 87 85 718 46 89 3.16 0.49 1.17 1.00 0.26 0.52 Y Y N Y N Y 371 281 249 0 23 197 3.83 4.46 1.59 0.00 0.22 1.99 162 389 180 0 276 24 1.18 5.32 1.24 0.00 2.71 0.21 371 154 209 0 362 368 1.96 1.62 2.33 0.00 3.62 2.06 8 9 10 11 12 2801 2536 2673 273 2550 159 149 140 138 135 1.50 1.36 1.26 0.67 1.47 113 58 103 3 97 1.37 1.16 0.63 0.07 1.08 Y N Y N Y 199 122 302 548 50 2.14 1.29 3.55 2.57 0.57 124 396 52 0 199 1.14 2.74 0.40 0.00 3.06 201 19 104 3 192 1.32 0.25 0.46 0.03 1.16 Flag * Circuits are flagged as Y if they reached or exceeded 250% of the systemwide SAIDI value for the calendar year of 2025 Excludes the following: • Outages caused by Power Supply or Transmission Problems external to UI • Scheduled outages • Outages caused by Customer Equipment connected to UI lines • Major Storms 118Page 119 of 176
03/31/2026 Docket No. 86-12-03 The United Illuminating Company SAIDI/SAIFI Worst 4% of All Circuits Ranked by Average SAIFI 1 512 Average SAIDI SAIFI (Mins) 2.97 228 N 2024 SAIDI SAIFI (Mins) 4.46 281 2 3 4 5 6 7 2688 1862 2683 2635 2684 2801 2.53 2.18 1.70 1.62 1.58 1.50 324 353 177 126 181 159 3.16 2.00 0.26 0.23 1.17 1.37 391 780 46 46 85 113 Y Y N N Y Y 3.83 1.00 0.22 2.19 1.59 2.14 371 115 23 102 249 199 1.18 3.00 2.71 0.02 1.24 1.14 162 188 276 2 180 124 1.96 2.71 3.62 4.03 2.33 1.32 371 329 362 354 209 201 8 9 10 11 12 2550 1531 2536 1694 2503 1.47 1.39 1.36 1.33 1.33 135 99 149 85 79 1.08 0.83 1.16 3.05 0.51 97 80 58 152 41 N N Y Y N 0.57 1.18 1.29 0.59 3.79 50 116 122 33 246 3.06 1.13 2.74 1.13 0.99 199 84 396 94 30 1.16 2.41 0.25 0.56 0.02 192 117 19 60 1 Rank Circuit 2025 SAIDI SAIFI (Mins) 0.49 87 2025 Flag 2023 SAIDI SAIFI (Mins) 5.32 389 2022 SAIDI SAIFI (Mins) 1.62 154 * Circuits are flagged as Y if they reached or exceeded 250% of the systemwide SAIFI value for the calendar year of 2025 Excludes the following: • Outages caused by Power Supply or Transmission Problems external to UI • Scheduled outages • Outages caused by Customer Equipment connected to UI lines • Major Storms 119Page 120 of 176
03/31/2026 Docket No. 86-12-03 Appendix 16: Corrective Action Plans a. Reliability Corrective Action Plans for Tier 1 Circuits Worst 4% Circuit CEMI-7 + CELID-9 Percentages – 2025 CIRCUIT NUMBER 512 510 3466 506 1694 2684 2800 2617 2803 514 2615 2801 SUBSTATION INDIAN WELL INDIAN WELL POOTATUCK INDIAN WELL MIX AVE HAWTHORNE TRUMBULL OLD TOWN TRUMBULL INDIAN WELL OLD TOWN TRUMBULL CITY or TOWN SHELTON SHELTON SHELTON SHELTON HAMDEN EASTON, FAIRFIELD TRUMBULL TRUMBULL SHELTON, TRUMBULL SHELTON BRIDGEPORT, EASTON, FAIRFIELD, TRUMBULL SHELTON, TRUMBULL * Circuits were selected using the Tier 1 All-In WPC lists from July 2024 – June 2025 from Appendix 14a and Appendix 14e 120Page 121 of 176
03/31/2026 Docket No. 86-12-03 Indian Well 512 – Town of Shelton 4 – Year Outage Cause Summary Number of Outages 6 1 1 16 5 1 68 2 Outage Type Animal Contact Cable Fault Conductor Failure Connector Failure Fuse Loose Connection Tree Contact Voltage Regulator Number of Outages 1 2 4 6 1 8 3 1 Outage Type Bird Contact Clearance Conductor Off Pin Cutout Lightning Transformer Vehicle Accident X-Arm Brace Number of Outages 1 1 Outage Type Transformer Unknown 4 – Year CELID-9 Outage Cause Summary Number of Outages 1 14 Outage Type Fuse Tree Contact Reliability Improvement – 2026 Recommendations Indian Well Circuit 512 was included in the 2025 TDRP Reliability Corrective Action Plan. Recommendations for 2026 are listed below: 1. Include circuit 512 in the Vegetation Management program. 2. Spot Tree Trimming at the following locations: a) 1PH – From pole 6514 to pole 6537 (Dickinson Dr). 3. Install (2) 25K fuses at pole 9316 and pole 9315 (Vista Dr). 4. 2025 CELID9 events: a) One CELID9 outage caused by a transformer affecting 3 customers. b) Ten CELID9 outages caused by tree contact affecting 290 customers. c) One CELID9 outage caused by an unknown reason affecting 1 customer. d) Work with Operations to identify potential solutions to help limit customer exposure to CELID9 events during blue sky days. 121Page 122 of 176
03/31/2026 Docket No. 86-12-03 Indian Well 510 – Town of Shelton 4– Year Outage Cause Summary Number of Outages 1 1 3 3 1 1 Outage Type Bird Contact Conductor Off Pin Cutout Transformer UI Human Error X-Arm/Brace Number of Outages 1 4 4 10 4 Outage Type Conductor Failure Connector Failure Meter Tree Contact Vehicle Accident Number of Outages 8 Outage Type Tree Contact 4 – Year CELID-9 Outage Cause Summary Number of Outages 1 Outage Type Transformer Reliability Improvement – 2026 Recommendations Indian Well Circuit 510 was included in the 2025 TDRP Reliability Corrective Action Plan. Recommendations for 2026 are listed below: 1. Include circuit 510 in the Vegetation Management program. 2. Spot Tree Trimming on pole 7682 (Meadow St). 3. 2025 CELID9 events: a) Two CELID9 outages caused by tree contact affecting 57 customers. b) Work with Operations to identify potential solutions to help limit customer exposure to CELID9 events during blue sky days. 122Page 123 of 176
03/31/2026 Docket No. 86-12-03 Pootatuck 3466 – Town of Shelton 4– Year Outage Cause Summary Number of Outages 6 1 1 2 1 2 29 Outage Type Animal Contact Clearance Conductor Off Pin Cutout Lightning Meter Tree Contact Number of Outages 3 3 4 2 2 2 3 Outage Type Cable Fault Conductor Failure Connector Failure Fuse Loose Connection Transformer Unknown Number of Outages 1 4 Outage Type Connector Failure Tree Contact 4 – Year CELID-9 Outage Cause Summary Number of Outages 1 1 Outage Type Cable Fault Lightning Reliability Improvement – 2026 Recommendations Pootatuck Circuit 3466 was included in the 2025 TDRP Reliability Corrective Action Plan. Recommendations for 2026 are listed below: 1. Include circuit 3466 in the Vegetation Management program. 2. Replace the four skirt cutouts on the following 19 poles: 9303, 2419, 8915, 1806, 8372, 8734, 879, 1885, 8921, 1449, 9196, 9341, 854, 1864, 8642, 9823, 9635, 9347, and 10240. 3. 2025 CELID9 events: a) One CELID9 outage caused by an underground cable fault affecting 1 customer. b) One CELID9 outage caused by a connector failure affecting 1 customer. c) One CELID9 outage caused by tree contact affecting 7 customers. d) Work with Operations to identify potential solutions to help limit customer exposure to CELID9 events during blue sky days. 123Page 124 of 176
03/31/2026 Docket No. 86-12-03 Indian Well 506 – Town of Shelton 4– Year Outage Cause Summary Number of Outages 6 Outage Type Animal Contact Number of Outages 1 4 4 3 1 2 12 2 Clearance Conductor Off Pin Cutout Hot Line Clamp Loose Connection Transformer UI Human Error 7 22 10 1 1 56 2 Conductor Failure Connector Failure Fuse Lightning Pole Tree Contact Vehicle Accident Outage Type Conductor Failure Foreign Objects Outage Type Cable Fault 4 – Year CELID-9 Outage Cause Summary Number of Outages 1 1 Outage Type Cable Fault Connector Failure Number of Outages 1 1 2 1 27 7 Fuse Loose Connection Tree Contact Unknown 2 2 1 1 Lightning Transformer TXF Secondary Breaker Vehicle Accident Reliability Improvement – 2026 Recommendations Indian Well Circuit 506 was included in the 2025 TDRP Reliability Corrective Action Plan. Recommendations for 2026 are listed below: 1. Include circuit 506 in the Vegetation Management program. 2. Spot Tree Trimming at the following locations: a) Pole 3365 to pole 968 (Ripton Rd) b) Pole 6456 to pole 1020 (Mohegan Rd) c) Pole 5202 to pole 5203 (Poplar Dr) 124Page 125 of 176
03/31/2026 Docket No. 86-12-03 Indian Well 506 – Town of Shelton - continued 3. Equip all reclosers with SCADA or programming for bi-directional fault sensing, and upgrade tie points to SCADA (aerial cable outage ~1.5 hours, zone 1 outage ~9 hours, both took out entire circuit). 4. 2025 CELID9 events: a) Five CELID9 outages caused by tree contact affecting 63 customers. b) Two CELID9 outages caused by unknown reasons affecting 2 customers. c) Work with Operations to identify potential solutions to help limit customer exposure to CELID9 events during blue sky days. 125Page 126 of 176
03/31/2026 Docket No. 86-12-03 Mix Ave 1694 – Town of Hamden 4 – Year Outage Cause Summary Number of Outages 3 1 3 1 4 1 Outage Type Animal Contact Conductor Off Pin Cutout Pole Transformer Unknown Number of Outages 1 3 4 1 5 1 Outage Type Conductor Failure Connector Failure Meter Terminator Failure Tree Contact Vehicle Accident Number of Outages Outage Type 4 – Year CELID-9 Outage Cause Summary Number of Outages 2 Outage Type Tree Contact Reliability Improvement – 2026 Recommendations Mix Ave Circuit 1694 was included in the 2025 TDRP Reliability Corrective Action Plan. Recommendations for 2026 are listed below: 1. Include circuit 1694 in the Vegetation Management program. 2. Spot Tree Trimming between pole 891 and pole 5826 (Mix Ave). 3. Replace existing overhead bare wire with 397 AL TW from pole 883 to pole 834 (Mix Ave). Look to replace cross arms as needed. 4. 2025 CELID9 events: a) One CELID9 outage caused by tree contact affecting 59 customers. b) Work with Operations to identify potential solutions to help limit customer exposure to CELID9 events during blue sky days. 126
Text of UI-Attachment 2.pdf
Extracted from the file · 108 pages · 171,300 characters
Text of UI-Attachment 3.pdf
Extracted from the file · 79 pages · 105,929 characters
Text of UI-Attachment 4a.pdf
Extracted from the file · 60 pages · 136,974 characters
Text of UI-Attachment 4b.pdf
Extracted from the file · 32 pages · 73,024 characters
Text of UI-Attachment 5.pdf
Extracted from the file · 10 pages · 12,154 characters
Text of UI-Attachment 6.pdf
Extracted from the file · 29 pages · 55,721 characters
Text of UI-Attachment 7.pdf
Extracted from the file · 33 pages · 83,950 characters
Text of UI-Attachment 9.pdf
Extracted from the file · 14 pages · 33,843 characters
Text of UI-Attachment 11.pdf
Extracted from the file · 4 pages · 13,890 characters
Text of UI-Attachment 12.pdf
Extracted from the file · 36 pages, 2 without text · 106,019 characters
As listed on the current system
Compliance Filings, 10/01/2026 [26-08-07] Order No.No 4 in docket 17-12-03RE05 / Eversource Energy /