Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Compliance Filing

Compliance Filing, Order No. No

Compliance filingFiled by Eversource Energy24 files
Part of docket 26-08-07Open
  • Electric
Innovative Energy Solutions Program Cycle 5

Files24

Search terms highlighted
Eversource rate increase is on 5 pages across 2 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
2 pages match
Words on different pages

Text of ES-Attachment 2b 2026 TDRP-Appendix 8.pdf

Extracted from the file · 23 pages · 37,559 characters

Text of ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES-Attachment 3.pdf

Extracted from the file · 1 page · 7,205 characters

Text of ES-Attachment 3.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES-Attachment 4.pdf

Extracted from the file · 44 pages · 108,591 characters

Text of ES-Attachment 4.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES-Attachment 5.pdf

Extracted from the file · 30 pages · 79,263 characters

Words on different pagesRead the text of ES-Attachment 5.pdf

Text of ES-Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of ES-Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Words on different pages
  1. Page 16 of 176

    03/31/2026 Docket No. 86-12-03 Chart IV-1.4 Customers Experiencing Multiple Interruptions (2025) 16
  2. Page 17 of 176

    03/31/2026 Docket No. 86-12-03 Chart IV-1.5 Customers Experiencing Long Interruption Duration (2025) 17
  3. Page 18 of 176

    03/31/2026 Docket No. 86-12-03 Per Docket No. 17-12-03RE08, UI is to include reliability metrics calculated with and without the inclusion of major storms and planned outages in its annual report. Table IV.4 below provides the SAIDI, SAIFI, CAIDI, MAIFI, CEMI, CELID, CEMM, and CEMSMI values for 2025. The four customer-centric metrics are further segmented into tranches of three or more, five or more, seven or more, and nine or more. SAIDI SAIFI CAIDI MAIFI CEMI-3 CEMI-5 CEMI-7 CEMI-9 CELID-3 CELID-5 CELID-7 CELID-9 CEMM-3 CEMM-5 CEMM-7 CEMM-9 CEMSMI-3 CEMSMI-5 CEMSMI-7 CEMSMI-9 Excluding Major Storm & Planned 35 0.46 76 0.88 0.0239 0.0005 0.0000 0.0000 0.0304 0.0100 0.0051 0.0022 0.0957 0.0184 0.0061 0.0037 0.1680 0.0417 0.0103 0.0050 Excluding Major Storm 36 0.48 76 0.89 0.0268 0.0007 0.0000 0.0000 0.0318 0.0107 0.0056 0.0023 0.0961 0.0186 0.0061 0.0037 0.1736 0.0435 0.0109 0.0051 Including Major Storm 72 0.64 113 1.22 0.0465 0.0027 0.0003 0.0000 0.0875 0.0409 0.0249 0.0146 0.1605 0.0352 0.0112 0.0057 0.2668 0.0843 0.0241 0.0103 All Outages 73 0.66 111 1.22 0.0507 0.0030 0.0004 0.0000 0.0889 0.0416 0.0254 0.0147 0.1609 0.0355 0.0113 0.0057 0.2723 0.0866 0.0253 0.0105 Table IV.4 Per Docket No. 24-08-09, UI is to report on the number of CEMI-3, CEMI-5, CEMI-7, CELID-3, CELID-6, CELID-9, and CELID-12 customers as a ratio of total customers served consistent with the IEEE-1366 standard. The CEMI and CELID data are to both include and exclude major storms. Both the IEEE-1366 (Major Event Day) and General Statutes § 16-245y(a) (major storms, scheduled interruptions, power supply outages, and customer-caused) methodologies are to be utilized. Additionally, the CEMI and CELID data is to be broken out by outages on the secondary and primary distribution system, both separately and as a whole. A four-year rolling average of CEMI and CELID interruptions from the four years preceding the year in question is also to be included. Table IV.5 below lists a breakdown of primary vs. secondary classification based on outage voltage descriptions. 18
  4. Page 19 of 176

    03/31/2026 Docket No. 86-12-03 Voltage Description Secondary Service Net 120/208V Net 277/480V 2.4kV 4.16kV 13.8kV 115kV 345kV Sub 2.4/4kV Sub 13.8kV Primary / Secondary Secondary Secondary Secondary Secondary Primary Primary Primary Primary Primary Primary Primary Table IV.5 Table IV.6 below gives the CEMI and CELID breakdown for 2025 and four-year rolling average per Docket No. 24-08-09. All-In Primary / Secondary Primary Secondary Both KPI 2025 CEMI-3 CEMI-5 CEMI-7 CELID-3 CELID-6 CELID-9 CELID-12 CEMI-3 CEMI-5 CEMI-7 CELID-3 CELID-6 CELID-9 CELID-12 CEMI-3 CEMI-5 CEMI-7 CELID-3 CELID-6 CELID-9 CELID-12 0.0480 0.0027 0.0004 0.0866 0.0299 0.0139 0.0087 0.0001 0.0000 0.0000 0.0026 0.0011 0.0008 0.0004 0.0507 0.0030 0.0004 0.0889 0.0310 0.0147 0.0091 IEEE-1366 Average (’21 – ‘24) 0.0513 0.0083 0.0005 0.0756 0.0271 0.0136 0.0096 0.0001 0.0000 0.0000 0.0021 0.0007 0.0004 0.0002 0.0539 0.0086 0.0006 0.0773 0.0278 0.0140 0.0098 2025 0.0239 0.0014 0.0002 0.0338 0.0086 0.0021 0.0009 0.0000 0.0000 0.0000 0.0014 0.0005 0.0003 0.0001 0.0255 0.0015 0.0003 0.0352 0.0090 0.0024 0.0010 Table IV.6 IEEE-1366 removes the following: • Scheduled Outages • Major Event Days 19 Average (’21 – ‘24) 0.0366 0.0035 0.0004 0.0523 0.0132 0.0048 0.0018 0.0000 0.0000 0.0000 0.0015 0.0006 0.0003 0.0001 0.0378 0.0036 0.0004 0.0536 0.0138 0.0051 0.0019 Non-Excluded 2025 0.0228 0.0004 0.0000 0.0291 0.0072 0.0020 0.0008 0.0000 0.0000 0.0000 0.0012 0.0003 0.0002 0.0001 0.0238 0.0005 0.0000 0.0303 0.0075 0.0022 0.0009 Average (’21 – ‘24) 0.0322 0.0029 0.0004 0.0444 0.0109 0.0033 0.0010 0.0000 0.0000 0.0000 0.0013 0.0005 0.0003 0.0001 0.0331 0.0030 0.0004 0.0456 0.0114 0.0036 0.0012
  5. Page 20 of 176

    03/31/2026 Docket No. 86-12-03 Non-Excluded removes the following: • Outages caused by Power Supply or Transmission Problems external to UI • Scheduled Outages • Outages caused by Customer equipment connected to UI lines • Major Storms Per Docket No. 21-05-15RE02, the revised proposal for the Equitable Reliability PIM is comprised of the following four sub-metrics: (1) CEMI 5; (2) Percent of repeat CEMI 5 customers; (3) CELID 6; (4) Percent of repeat CELID 6 customers. The CEMI 5 and CELID 6 sub-metrics shall be calculated as directed in Order Nos. 1 and 2, respectively, of the 2024 Reliability and Resilience Decision. The percent of repeat CEMI 5 customers shall be calculated as the number of CEMI 5 customers who appear on the CEMI 5 lists for both the current year and the prior year divided by the total number of CEMI 5 customers in the current year. The percent of repeat CELID 6 customers shall be calculated as the number of CELID 6 customers who appear on the CELID 6 lists for both the current year and the prior year divided by the total number of CELID 6 customers in the current year. Table IV.7 below lists the CEMI-5 and CELID-6 breakdown of current and repeating customers. Method All-In IEEE-1366 NonExcluded Year CEMI-5 Repeat CEMI-5 CELID-6 Repeat CELID-6 Average 2025 2024 2023 2022 2021 2020 2025 2024 2023 2022 2021 2020 2025 2024 2023 2022 2021 2020 0.0030 0.0122 0.0150 0.0044 0.0027 0.0229 0.0015 0.0038 0.0059 0.0031 0.0014 0.0064 0.0005 0.0037 0.0058 0.0013 0.0012 0.0055 0.3365 0.3873 0.0245 0.1039 0.1665 0.0667 0.6277 0.2681 0.0534 0.1382 0.0000 0.0042 0.6000 0.2719 0.0305 0.0131 0.0000 0.0005 0.0310 0.0605 0.0163 0.0171 0.0173 0.3550 0.0090 0.0092 0.0153 0.0164 0.0141 0.0127 0.0075 0.0090 0.0109 0.0141 0.0118 0.0087 0.2323 0.0564 0.0666 0.0374 0.4848 0.1095 0.0500 0.0628 0.0709 0.0348 0.0629 0.0237 0.0588 0.0615 0.0456 0.0243 0.0372 0.0071 0.1507 0.1291 0.0306 0.0407 0.1678 0.1385 0.1720 0.0860 0.0364 0.0481 0.0196 0.0118 0.1667 0.0865 0.0232 0.0132 0.0125 0.0055 Table IV.7 IEEE-1366 removes the following: • Scheduled Outages • Major Event Days 20
  6. Page 21 of 176

    03/31/2026 Docket No. 86-12-03 Non-Excluded removes the following: • Outages caused by Power Supply or Transmission Problems external to UI • Scheduled Outages • Outages caused by Customer equipment connected to UI lines • Major Storms Per Docket No. 21-05-15RE02, the Authority maintains its Original Straw Proposal recommendation to include an All-in SAIDI Scorecard in the PBR Performance Mechanism portfolio. This additional scorecard provides a high-level view of each of the EDC’s resilience performance by showing the duration of service interruptions across all weather conditions. The Authority suggests that the All-in SAIDI calculation should follow the IEEE methodology, including all weather events but excluding loss of supply and customer-side events. The Authority also proposes two benchmarks for the All-in SAIDI scorecard, both a 10-year historical rolling average and a five-year historical rolling. Table IV.8 below lists the historical All-in SAIDI following the IEEE methodology. Year SAIDI (Minutes) 5-Year Average SAIDI (Minutes) 10-Year Average SAIDI (Minutes) 2025 2024 2023 2022 2021 2020 71 125 58 50 57 1293 317 333 375 381 385 136 226 220 222 494 676 581 Table IV.8 UI’s All-in SAIDI values are heavily skewed by major storms. The calculated values from Table IV.8 include major storms that date back all the way to 2010. Chart IV.6 below gives more insight into this. While 2018 had the greatest number of storm days in a single year at 22, the total customer hours impacted was negligible compared to other years. The most notable storms in this range include Tropical Storm Isaias in 2020 (7-day UI storm totaling around 6,435,808-meter hours affected), Hurricane Sandy in 2012 (9-day UI storm totaling around 14,215,106-meter hours affected), and Tropical Storm Irene in 2011 (6-day UI storm totaling around 8,579,929-meter hours affected). The 10-Year averages start seeing significant drops once some of these respective years start falling off. 21
  7. Page 22 of 176

    03/31/2026 Docket No. 86-12-03 Chart IV-2 – Total Meter Hours Affected + Storm Days per Year 22
  8. Page 23 of 176

    03/31/2026 Docket No. 86-12-03 V. 2021 2022 2023 2024 2025 Blue-Sky, Gray-Sky, Blue-Sky + Gray-Sky, and Dark-Sky (All-In) Performance Blue-Sky Planned Gray-Sky Blue + Gray-Sky Dark-Sky All-In SAIDI 0.66 0.06 0.24 0.90 0.00 0.96 SAIFI 0.46 0.05 0.11 0.57 0.00 0.62 CAIDI 1.44 1.16 2.17 1.58 0.00 1.55 SAIDI 0.64 0.07 0.12 0.76 0.00 0.83 SAIFI 0.44 0.04 0.04 0.48 0.00 0.53 CAIDI 1.47 1.75 2.65 1.58 0.00 1.59 SAIDI 0.71 0.06 0.22 0.93 0.00 0.98 SAIFI 0.58 0.03 0.17 0.75 0.00 0.78 CAIDI 1.23 1.89 1.28 1.24 0.00 1.27 SAIDI 0.81 0.05 1.22 2.03 0.00 2.08 SAIFI 0.61 0.03 0.18 0.79 0.00 0.82 CAIDI 1.32 1.90 6.87 2.57 0.00 2.54 SAIDI 0.58 0.02 0.62 1.20 0.00 1.22 SAIFI 0.46 0.02 0.18 0.64 0.00 0.66 CAIDI 1.26 1.20 3.41 1.88 0.00 1.86 Table V.1 23
  9. Page 24 of 176

    03/31/2026 Docket No. 86-12-03 IEEE-1366 Blue-Sky, Gray-Sky, Blue-Sky + Gray-Sky, and Dark-Sky* 2021 2022 2023 2024 2025 Blue-Sky Gray-Sky Blue + Gray-Sky Dark-Sky SAIDI 0.66 0.07 0.73 0.17 SAIFI 0.46 0.05 0.51 0.06 CAIDI 1.44 1.33 1.43 2.91 SAIDI 0.65 0.12 0.77 0.00 SAIFI 0.44 0.04 0.49 0.00 CAIDI 1.47 2.65 1.57 0.00 SAIDI 0.71 0.12 0.83 0.10 SAIFI 0.58 0.05 0.62 0.12 CAIDI 1.23 2.64 1.34 0.77 SAIDI 0.81 0.01 0.82 1.21 SAIFI 0.61 0.00 0.62 0.17 CAIDI 1.32 2.40 1.33 6.96 SAIDI 0.58 0.08 0.65 0.54 SAIFI 0.46 0.05 0.51 0.13 CAIDI 1.26 1.51 1.29 4.15 Table V.2 *IEEE-1366 calculation excludes planned outages 24
  10. Page 25 of 176

    03/31/2026 Docket No. 86-12-03 VI. Causes of Outages The causes of service interruptions have been classified into five categories in accordance with Docket 86-12-03, Order 1.b. These categories are as follows: 1. Forced Transmission & Power Supply Related Outages 2. Scheduled or Prearranged Outages for Maintenance & Construction 3. Major Storm Related Outages 4. Customer Caused Outages 5. Distribution System The components of the "Distribution System", (“All Others”) category is as follows: • Animal/Bird Contact • Lightning • Tree Contact • Accident a. Vehicle b. Foreign Objects c. Employee Error • Equipment Failure a. Overhead System b. Underground Cable c. Direct-Buried Cable d. Transformer e. Substation f. Transmission g. Other Equipment • Miscellaneous a. Overload b. Other c. Unknown Detailed definitions of the categories are in Appendix 12: “Common Categories for Causes of Outages” Percentage of outages caused by each category can be seen below on Charts V-1.1 and 1.2, V-2.1 and 2.2, and V-3.1 and 3.2. As is evident from these charts, excluding major storms, the category "All Others," which corresponds to "Distribution System," contains the majority of customer interruptions and lost meters. Lost meter-time can be greatly affected by major storms; barring a 25

Text of UI-Attachment 2.pdf

Extracted from the file · 108 pages · 171,300 characters

Text of UI-Attachment 3.pdf

Extracted from the file · 79 pages · 105,929 characters

Words on different pagesRead the text of UI-Attachment 3.pdf

Text of UI-Attachment 4a.pdf

Extracted from the file · 60 pages · 136,974 characters

Text of UI-Attachment 4b.pdf

Extracted from the file · 32 pages · 73,024 characters

Text of UI-Attachment 5.pdf

Extracted from the file · 10 pages · 12,154 characters

Words on different pagesRead the text of UI-Attachment 5.pdf

Text of UI-Attachment 6.pdf

Extracted from the file · 29 pages · 55,721 characters

Words on different pagesRead the text of UI-Attachment 6.pdf

Text of UI-Attachment 7.pdf

Extracted from the file · 33 pages · 83,950 characters

Words on different pagesRead the text of UI-Attachment 7.pdf

Text of UI-Attachment 9.pdf

Extracted from the file · 14 pages · 33,843 characters

Words on different pagesRead the text of UI-Attachment 9.pdf

Text of UI-Attachment 11.pdf

Extracted from the file · 4 pages · 13,890 characters

Text of UI-Attachment 12.pdf

Extracted from the file · 36 pages, 2 without text · 106,019 characters

As listed on the current system

Compliance Filings, 10/01/2026 [26-08-07] Order No.No 4 in docket 17-12-03RE05 / Eversource Energy /

This filing on the current system (opens in a new tab)