Compliance Filing
Compliance Filing, Order No. No
Files24
Joint Cover Letter re Compliance No 4.pdf
PDF · 143 KB · 2 pagesText searchable
Download Joint Cover Letter re Compliance No 4.pdfRead the text of Joint Cover Letter re Compliance No 4.pdf
26-08-07 Comp Order 4.pdf
PDF · 589 KB · 29 pagesText searchable
Download 26-08-07 Comp Order 4.pdfRead the text of 26-08-07 Comp Order 4.pdf
ES-Attachment 2a 2026 TDRP-Appendix 8.pdf
PDF · 380 KB · 23 pagesText searchable
Download ES-Attachment 2a 2026 TDRP-Appendix 8.pdfRead the text of ES-Attachment 2a 2026 TDRP-Appendix 8.pdf
ES-Attachment 2b 2026 TDRP-Appendix 8.pdf
PDF · 379 KB · 23 pagesText searchable
Download ES-Attachment 2b 2026 TDRP-Appendix 8.pdfRead the text of ES-Attachment 2b 2026 TDRP-Appendix 8.pdf
ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx
Excel · 68 KBText searchable
Download ES-Attachment 2b 2026 TDRP-Appendix 8.xlsxRead the text of ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx
ES-Attachment 3.pdf
PDF · 40 KB · 1 pageText searchable
Download ES-Attachment 3.pdfRead the text of ES-Attachment 3.pdf
ES-Attachment 3.xlsx
Excel · 25 KBText searchable
Download ES-Attachment 3.xlsxRead the text of ES-Attachment 3.xlsx
ES-Attachment 4.pdf
PDF · 239 KB · 44 pagesText searchable
Download ES-Attachment 4.pdfRead the text of ES-Attachment 4.pdf
ES-Attachment 4.xlsx
Excel · 67 KBText searchable
Download ES-Attachment 4.xlsxRead the text of ES-Attachment 4.xlsx
ES-Attachment 5.pdf
PDF · 650 KB · 30 pagesText searchable
Download ES-Attachment 5.pdfRead the text of ES-Attachment 5.pdf
ES-Attachment 1.xlsx
Excel · 5.2 MBText searchable
Download ES-Attachment 1.xlsxRead the text of ES-Attachment 1.xlsx
ES-Attachment 1.xlsx
Excel · 5.2 MBText searchable
Download ES-Attachment 1.xlsxRead the text of ES-Attachment 1.xlsx
UI-Attachment 1.pdf
PDF · 4.4 MB · 176 pagesText searchable
Download UI-Attachment 1.pdfRead the text of UI-Attachment 1.pdf
UI-Attachment 2.pdf
PDF · 1.9 MB · 108 pagesText searchable
Download UI-Attachment 2.pdfRead the text of UI-Attachment 2.pdf
UI-Attachment 3.pdf
PDF · 8.6 MB · 79 pagesText searchable
Download UI-Attachment 3.pdfRead the text of UI-Attachment 3.pdf
UI-Attachment 4a.pdf
PDF · 854 KB · 60 pagesText searchable
Download UI-Attachment 4a.pdfRead the text of UI-Attachment 4a.pdf
UI-Attachment 4b.pdf
PDF · 120 KB · 32 pagesText searchable
Download UI-Attachment 4b.pdfRead the text of UI-Attachment 4b.pdf
UI-Attachment 5.pdf
PDF · 96 KB · 10 pagesText searchable
Download UI-Attachment 5.pdfRead the text of UI-Attachment 5.pdf
UI-Attachment 6.pdf
PDF · 465 KB · 29 pagesText searchable
Download UI-Attachment 6.pdfRead the text of UI-Attachment 6.pdf
UI-Attachment 7.pdf
PDF · 288 KB · 33 pagesText searchable
Download UI-Attachment 7.pdfRead the text of UI-Attachment 7.pdf
UI-Attachment 9.pdf
PDF · 694 KB · 14 pagesText searchable
Download UI-Attachment 9.pdfRead the text of UI-Attachment 9.pdf
UI-Attachment 11.pdf
PDF · 162 KB · 4 pagesText searchable
Download UI-Attachment 11.pdfRead the text of UI-Attachment 11.pdf
UI-Attachment 12.pdf
PDF · 652 KB · 36 pagesText searchable
Download UI-Attachment 12.pdfRead the text of UI-Attachment 12.pdf
Text of ES-Attachment 2b 2026 TDRP-Appendix 8.pdf
Extracted from the file · 23 pages · 37,559 characters
Text of ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ES-Attachment 3.pdf
Extracted from the file · 1 page · 7,205 characters
Text of ES-Attachment 3.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ES-Attachment 4.pdf
Extracted from the file · 44 pages · 108,591 characters
Text of ES-Attachment 4.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ES-Attachment 5.pdf
Extracted from the file · 30 pages · 79,263 characters
Text of ES-Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Text of ES-Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Page 43 of 176
03/31/2026 Docket No. 86-12-03 iv. Utility Poles UI is the custodian of roughly 147,000 poles in the service territory. This program replaces deteriorated poles identified in the UI maintenance pole inspection program that do not meet established NESC standards for the amount of solid wood remaining at the base of the pole. Additionally, this program also replaces poles identified by visual inspections or resulting from field visits by UI field personnel. The volume of pole replacements is forecast based on the planned number of poles to be inspected multiplied by the historical average failure rate per year (typically 3.1%). This program is necessary to achieve compliance with NESC requirements, which maintains safety for the public and utility workers. Additionally, the UI distribution system reliability and resiliency are improved, as poles are replaced based on current standards and as pole loading analysis determines (per the NESC Northeast NESC wind and radial ice modeling parameters). In 2025, approximately 34 poles were replaced. A total of 26 were replaced as part of the Pole Management Program and an additional 8 Non-Program Poles were replaced as well. The inspections that were conducted in 2023, 2024 and 2025 have produced a reject rate of 1.10% which equates to a backlog of 2023 (86 poles), 2024 (87 poles) and 2025 (98 poles), totaling 271 poles. The rejects identified have inspection ratings varying in severity. In 2026, the Company plans to complete a portion of the backlog of pole replacements originating from 2023-2025. The replacements will be prioritized based on the severity rating from the inspections. For 2026, approximately 138 poles will be replaced based on the severity rating for poles identified from the 2023-2025 inspections. The estimate includes 102 single phase pole replacements at $8,394/pole and 36 three phase pole replacements at $13,440/pole. The estimated cost of these replacements is approximately $1.34M. The inspection program in 2026 will identify ~20 emergency priority rejects which will require around an additional $225k. In 2026, in addition to the ground line deteriorated pole inspections, the Company will also be commencing an overhead inspection cycle, and it is expected that investment will be required to remediate critical deficiencies such as cracked pole tops, primary cable off pins, etc. Additional funding may be required for these items and will be monitored as the overhead inspections are completed. The pole replacement program budget for 2026 is approximately $1,550,574. 43Page 44 of 176
03/31/2026 Docket No. 86-12-03 v. Circuit Performance Correction UI employs an incident-based outage reporting system to help determine the need for corrective action on circuits whose reliability has fallen outside of UI's Reliability Criteria. The Company has found this system to be highly responsive in that it minimizes the cycle time between outages, determination of a reliability problem, and corrective action. The trigger for circuit performance correction is deterministic; however, the corrective action typically involves construction and/or maintenance which will help minimize the probability of a future interruption. Each March, TDRP upgrades are planned to enhance reliability performance on the worst 4% of UI circuits. By addressing existing reliability issues, this program helps provide reliability improvements. The Company also monitors outage trends to identify and address threats to reliability as needed. The RE08-defined Worst Performing Circuit Program 2.0 now identifies TDRP circuits using CEMI (Customers Experiencing Multiple Interruptions) and CELID (Customers Experiencing Long Interruption Durations). This new approach focuses on outlier customers to bring them up to system-wide reliability targets, unlike the previous method, which targeted circuits most impacting system-level reliability. The scope includes: 1. Circuit Identification: Utilize CEMI and CELID metrics to identify customers in tier-9 and tier-7 priority lists requiring reliability improvement. 2. Inspection and Analysis: Conduct thorough inspections and analyses to determine the root causes of reliability issues. 3. Tree-Trimming Coordination: Address targeted tree trimming work at circuit sections that are impacting outlier customers. In many cases, tree trimming refusals correlate with high CEMI rates, and the Company ability to control may be limited by customer permissions. 4. Upgrade Planning: Develop and implement upgrade plans for identified locations, focusing on enhancing reliability and reducing outage durations for outlier customers. 5. Monitoring and Reporting: Continuously monitor the performance of upgraded circuits and report on improvements and remaining challenges. The 2026 Budget for Circuit Performance Correction is approximately $361,941. vi. Network Infrastructure The United Illuminating Company Network Infrastructure Program project consists of the installation of the underground network monitoring system including transformer ruggedized telemetry Link, Liquid temperature gauge, pressure gauge, vault water float switch, ambient 44Page 45 of 176
03/31/2026 Docket No. 86-12-03 temperature probe, HMI screen, cisco ethernet switches, fiber optic, G&W network primary switches, replacement of deteriorated network transformer and network protector. This project also targets and replaces all the network transformers and protectors that are deteriorated to prevent any failure in the network. The United Illuminating Company has installed a microprocessor-controlled network relays in the underground network vaults within the City of New Haven and the City of Bridgeport. The MPCV relays are equipped with communication capabilities that allow remote monitoring and control of the network protector. Currently, United Illumination Company has no systems in place in the underground network system that can provide the communication link between the grid devices and operators in remote locations. United Illuminating Company’s objective is to analyze several of the available communication technologies in order to determine the solution best suited for this application The need for network monitoring system in UI’s underground distribution secondary networks is very important since there is limited visibility into this part of the distribution system. This need became evident during an unscheduled outage in 2010 when a fault in the New Haven Network led to a fire at a customer vault. The initial feeder fault occurred and escalated into a two-feeder fault as a result of a stuck network protector that caused an alive on backfeed condition. This incident caused prolonged customer outage and the Company incurred approximately $1.2 million dollars in cost to remediate the situation. Incidents such as the one just described pose a safety risk for the general public and UI workers. A monitoring and control system for the secondary networks can be used to prevent such incidents from becoming major events. A communication system is also extremely beneficial to the Company day-to-day operation. This can be used by the System Operators to identify stuck network protectors and attempt to open remotely or dispatch a crew to the identified location to open locally. Currently, when a network protector gets stuck, UI crews must go to each network vault to find the protector that is stuck closed and open it manually. Locating the stuck protector can take several hours depending on the number of vaults on the feeder and the time of the day. This program is reactive in nature based on findings in the field so this scope may change. During the course of the inspections, crews typically discover problems that need to be addressed for worker and public safety. For 2026, UI is forecasting the following work: • Replace two ventilation grates @ $20,000 each • Replace one access hatch @ $50,000 each • Replace one transformer / protector @ $160,000 each The 2026 budget for Network Infrastructure is approximately $249,777. 45Page 46 of 176
03/31/2026 Docket No. 86-12-03 vii. Switchgear Replacement There are over 100 high voltage non-network services (greater than 600 volts) across UI’s service territory. The Company operates, maintains, and in many cases owns the switching demarcations. Through a specific inspection plan, UI will identify and prioritize the locations that have reached the end of their useful life, and/or present concerns ranging from safety, operational difficulties, code/access issues, and environmental. The Company will prepare engineering designed solutions for addressing these issues, up to and including replacement of service demarcations. Work plans will be executed alongside each customer as the program continues until all locations have been identified, and shortfalls have been addressed. Each plan will need customer involvement and acceptance, as the majority of UI equipment and construction will be on private property. There will also be locations that include UI owned transformers in customer owned vaults that are also in poor condition and may need to be relocated as part of the program, on a case by case review. This program will not only help maintain reliable service but also keep UI workers safe. In 2026, UI plans to replace L152 at Bella Vista on 339 Eastern St, New Haven. The 2026 budget for Switchgear Replacement is approximately $1,064,843 46Page 47 of 176
03/31/2026 Docket No. 86-12-03 C. Capacity i. Distribution Transformers In 1976, the manufacturing of polychlorinated biphenlys (PCBs) was banned. In 1982, the Company put in place a specification for electrical insulating oil which required the transformer manufacturer to supply transformers with zero parts per million PCB content. At the time, the Company did not engage in a program of replacing all transformers prior to 1982. Therefore, pre-1982 transformers with unknown PCB content still exist on the system. The Company owns and maintains over 50,000 distribution transformers on the electric system. During 2010, the Company completed an engineering survey of all distribution transformers on the system. The survey determined the need to replace over 14,000 transformers due to unknown PCB content, condition and/or loading levels. As of the end of 2025, approximately 5,368 transformers (an increase of 85) have been replaced. The remaining transformers will be replaced on a scheduled programmatic basis. This is a 20-year program which concentrates on eliminating PCB and overload conditions during the first half of the program and replacements in the second period due to age and condition. The rate of replacement is evaluated each year and CAPEX requirements are based on program progress and balanced with resource and material availability. This program has been significantly reduced in funding over recent years (2020-2023) due to supply chain issues. And for 2024, the program was deferred entirely with no funding forecasted. However, as other work is performed in UI Distribution Operations, if a pole has been previously identified as a TARP location, that work is reviewed and may be required to be done in conjunction with the other distribution work. There is no projected budget for 2026. The program is currently expected to resume in 2027. ii. Energy Storage Resiliency This battery storage project consists of installing a 8.12 MW, 32.5 MWh Battery Energy Storage System (BESS) mid-circuit on Water St Circuit 1526. This circuit currently feeds around 1,600 New Haven customers. The battery will be used to provide circuit resiliency and capacity benefits. Specific use cases for this project include: 1. Resiliency and back up to a targeted section of a poor performing circuit 2. Provides back-up to LMI and environmental justice customers 3. Provides targeted relief during area capacity events 4. Provides load relief to an overloaded circuit 47Page 48 of 176
03/31/2026 Docket No. 86-12-03 Energy storage will be required to meet the State’s clean energy goals enabling the integration of renewable intermittent resources like solar and wind. This project addresses an existing operational resiliency need and utilizes existing connected intermittent resources to optimize battery charging and discharging cycles. This project also helps Connecticut move towards its goal of 1 GW of energy storage by 2030. The 2026 budget for this Energy Storage Resiliency project is approximately $2,302,374. 48Page 49 of 176
03/31/2026 Docket No. 86-12-03 D. Enhancement Programs UI enhances the existing distribution system as follows: i. URD Project Rebuilds/Rehabilitation Cable replacement and/or refurbishment, coupled with transformer replacements, in older underground residential projects where UI’s equipment may be approaching the end of its useful life. Reference Section 7a Residential Line for more information. ii. Highest CEMI-3 and CELID-9 Circuit Improvements Appendix 14a lists the Tier 1 Worst Performing Circuits by All-In CEMI-3 for the period of July 2024 to June 2025. Appendix 14b lists the Tier 1 Worst Performing Circuits by Non-Excluded CEMI-3 for the period of July 2024 to June 2025. Appendix 14c lists the Tier 1 Worst Performing Circuits by All-In CEMI-3 for the calendar year of 2025. Appendix 14d lists the Tier 1 Worst Performing Circuits by Non-Excluded CEMI-3 for the calendar year of 2025. Appendix 14e lists the Tier 1 Worst Performing Circuits by All-In CELID-9 for the period of July 2024 to June 2025. Appendix 14f lists the Tier 1 Worst Performing Circuits by Non-Excluded CELID-9 for the period of July 2024 to June 2025. Appendix 14g lists the Tier 1 Worst Performing Circuits by All-In CELID-9 for the calendar year of 2025. Appendix 14h lists the Tier 1 Worst Performing Circuits by Non-Excluded CELID-9 for the calendar year of 2025. Appendix 16a describes the proposed reliability corrective action plans UI designed to improve the reliability of the four percent of the circuits with the highest CEMI-7 and CELID-9 percentages as determined by July 2024 to June 2025 interruption data per Docket No. 17-1203RE08. 49Page 50 of 176
03/31/2026 Docket No. 86-12-03 iii. Highest SAIDI/SAIFI Circuit Improvements Appendix 15a lists the Tier 2 Worst 100 Circuits by SAIDI ranking for the period of July 2024 to June 2025. A SAIDI threshold is determined by calculating 250% of the systemwide SAIDI value for the period of July 2024 to June 2025. Circuits where its July 2024 to June 2025 SAIDI values reach or exceed this threshold are flagged with Y. Appendix 15b lists the Tier 2 Worst 100 Circuits by SAIDI ranking for the calendar year of 2025. A SAIDI threshold is determined by calculating 250% of the systemwide SAIDI value for the calendar year of 2025. Circuits where its 2025 SAIDI values reach or exceed this threshold are flagged with Y. Appendix 15c lists the Tier 2 Worst 100 Circuits by SAIFI ranking for the period of July 2024 to June 2025. A SAIFI threshold is determined by calculating 250% of the systemwide SAIFI value for the period of July 2024 to June 2025. Circuits where its July 2024 to June 2025 SAIFI values reach or exceed this threshold are flagged with Y. Appendix 15d lists the Tier 2 Worst 100 Circuits by SAIFI ranking for the calendar year of 2025. A SAIFI threshold is determined by calculating 250% of the systemwide SAIFI value for the calendar year of 2025. Circuits where its 2025 SAIFI values reach or exceed this threshold are flagged with Y. Appendices 15e lists the worst 4% of all Circuits created by using the lists from Appendices 15a and 15c by alternating SAIDI and SAIFI circuit rankings. Circuits are flagged if the average SAIDI or SAIFI values reach or exceed 250% of the systemwide SAIDI or SAIFI values for the period of July 2024 to June 2025. Appendices 15f lists the worst 4% of all Circuits created by using the lists from Appendices 15b and 15d by alternating SAIDI and SAIFI circuit rankings. Circuits are flagged if the average SAIDI or SAIFI values reach or exceed 250% of the systemwide SAIDI or SAIFI values for the calendar year of 2025. Appendix 16b describes the proposed reliability corrective action plans UI designed to improve the reliability of the four percent of the circuits with the highest SAIDI and SAIFI values as determined by July 2024 to June 2025 interruption data per Docket No. 17-12-03RE08. iv. Status of Prior Corrective Actions The status of the previous year’s corrective action plans can be found in Appendix 17. 50Page 51 of 176
03/31/2026 Docket No. 86-12-03 v. Substation Flood Protection Weather events experienced in the recent years, along with revisions to Federal Emergency Management Agency (FEMA) flood maps have necessitated UI to take action to evaluate the risk and potential impact of a single 100-year coastal flooding event on its coastal substations and evaluate mitigating solution alternatives. The Company commissioned a study, "Coastal Substation Flooding Asset Condition Review". That study revealed that five of the Company's coastal substations are at significant risk of being incapacitated and/or destroyed by a single FEMA 100-year flood event. Singer Substation is a 345kV transmission substation that provides electricity from Bridgeport to Norwalk. The Singer Flood Mitigation project aims to provide flood protection to the critical transmission assets during severe weather conditions. The project scope includes the installation of flood walls and gates around the substation perimeter, reinforcement of the Gas Insulated Switch Gear (GIS) building walls, as well as installation of a storm water management system. The 2026 budget for this project is approximately $25,354,809. The Grand Ave/Mill River Flood Mitigation project is very similar. The scope includes the installation of flood walls and gates around the substation perimeter, modifications to river bulkhead, as well as installation of a storm water management system. To mitigate the risk, UI is installing a perimeter flood wall system, which includes a driven steel sheet pile flood wall below and above grade along the current fence line. The flood gates will have concrete foundations and a stormwater system for runoff discharge. The 2026 budget for this project is approximately $6,364,354. The Milvon Substation has a history of flooding. Water has reached the MOD operators, blowing fuses, and disrupting normal operations which has caused unplanned outages. The 100-year flood elevation in the area is 39 ft above sea level (based on the NAVD 88). The scope of this project is to raise all critical yard equipment above the base design elevation of 41 ft above sea level (plus 2 ft of the NAVD 88 elevation). The site slopes to the north (towards the Metro North Railroad) which is the low point of surrounding buildings and roadways. The 2026 budget for this project is approximately $1,146,057. 51Page 52 of 176
03/31/2026 Docket No. 86-12-03 E. Maintenance Programs UI's personnel follow specific procedures designed to reduce certain types of service outages. Among these procedures are the following: i. Tree Trimming UI follows the Vegetation Management Plan, (UPZ), performs hazard tree removals, and vine clearing in order to reduce the probability of tree related interruptions and damaging tree contacts to the electric infrastructure. For 2025 there were numerous instances where the Company was denied permission to trim. Refer to Appendix 13, “Vegetation Program Miles Trimmed & Tree Trimming Denials”, for additional details on both miles trimmed and trim denials. UI performs UPZ, in conjunction with hazard tree removals and the clearing of vines to reduce the probability of tree related outages. The budgets for the distribution and transmission line clearance programs along with the UPZ program for 2026 are as follows: Year ii. Company Distribution Line Clearance 2026 $1,477,599 2026 Enhanced Tree Trimming (Distribution) $13,893,779 Transmission ROW’s $1,788,801 Infrared Survey In order to detect potential failures, infrared inspections of three phase fused side-taps and three-phase mainline are performed annually. Bulk substations are inspected semi-annually and distribution substations annually. In 2019 the Company identified fused cutout failures related to a specific manufacturer and vintage. As a result, the Infrared survey was enhanced by identifying these locations and taking extra steps to thoroughly scan and replace defective fused cutouts. UI’s trained personnel inspect three phase main lines and three phase fused side taps annually. Bulk substations are inspected semi-annually and distribution substations annually. 52
Text of UI-Attachment 2.pdf
Extracted from the file · 108 pages · 171,300 characters
Text of UI-Attachment 3.pdf
Extracted from the file · 79 pages · 105,929 characters
Text of UI-Attachment 4a.pdf
Extracted from the file · 60 pages · 136,974 characters
Text of UI-Attachment 4b.pdf
Extracted from the file · 32 pages · 73,024 characters
Text of UI-Attachment 5.pdf
Extracted from the file · 10 pages · 12,154 characters
Text of UI-Attachment 6.pdf
Extracted from the file · 29 pages · 55,721 characters
Text of UI-Attachment 7.pdf
Extracted from the file · 33 pages · 83,950 characters
Text of UI-Attachment 9.pdf
Extracted from the file · 14 pages · 33,843 characters
Text of UI-Attachment 11.pdf
Extracted from the file · 4 pages · 13,890 characters
Text of UI-Attachment 12.pdf
Extracted from the file · 36 pages, 2 without text · 106,019 characters
As listed on the current system
Compliance Filings, 10/01/2026 [26-08-07] Order No.No 4 in docket 17-12-03RE05 / Eversource Energy /