Compliance Filing
Compliance Filing, Order No. No
Files24
Joint Cover Letter re Compliance No 4.pdf
PDF · 143 KB · 2 pagesText searchable
Download Joint Cover Letter re Compliance No 4.pdfRead the text of Joint Cover Letter re Compliance No 4.pdf
26-08-07 Comp Order 4.pdf
PDF · 589 KB · 29 pagesText searchable
Download 26-08-07 Comp Order 4.pdfRead the text of 26-08-07 Comp Order 4.pdf
ES-Attachment 2a 2026 TDRP-Appendix 8.pdf
PDF · 380 KB · 23 pagesText searchable
Download ES-Attachment 2a 2026 TDRP-Appendix 8.pdfRead the text of ES-Attachment 2a 2026 TDRP-Appendix 8.pdf
ES-Attachment 2b 2026 TDRP-Appendix 8.pdf
PDF · 379 KB · 23 pagesText searchable
Download ES-Attachment 2b 2026 TDRP-Appendix 8.pdfRead the text of ES-Attachment 2b 2026 TDRP-Appendix 8.pdf
ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx
Excel · 68 KBText searchable
Download ES-Attachment 2b 2026 TDRP-Appendix 8.xlsxRead the text of ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx
ES-Attachment 3.pdf
PDF · 40 KB · 1 pageText searchable
Download ES-Attachment 3.pdfRead the text of ES-Attachment 3.pdf
ES-Attachment 3.xlsx
Excel · 25 KBText searchable
Download ES-Attachment 3.xlsxRead the text of ES-Attachment 3.xlsx
ES-Attachment 4.pdf
PDF · 239 KB · 44 pagesText searchable
Download ES-Attachment 4.pdfRead the text of ES-Attachment 4.pdf
ES-Attachment 4.xlsx
Excel · 67 KBText searchable
Download ES-Attachment 4.xlsxRead the text of ES-Attachment 4.xlsx
ES-Attachment 5.pdf
PDF · 650 KB · 30 pagesText searchable
Download ES-Attachment 5.pdfRead the text of ES-Attachment 5.pdf
ES-Attachment 1.xlsx
Excel · 5.2 MBText searchable
Download ES-Attachment 1.xlsxRead the text of ES-Attachment 1.xlsx
ES-Attachment 1.xlsx
Excel · 5.2 MBText searchable
Download ES-Attachment 1.xlsxRead the text of ES-Attachment 1.xlsx
UI-Attachment 1.pdf
PDF · 4.4 MB · 176 pagesText searchable
Download UI-Attachment 1.pdfRead the text of UI-Attachment 1.pdf
UI-Attachment 2.pdf
PDF · 1.9 MB · 108 pagesText searchable
Download UI-Attachment 2.pdfRead the text of UI-Attachment 2.pdf
UI-Attachment 3.pdf
PDF · 8.6 MB · 79 pagesText searchable
Download UI-Attachment 3.pdfRead the text of UI-Attachment 3.pdf
UI-Attachment 4a.pdf
PDF · 854 KB · 60 pagesText searchable
Download UI-Attachment 4a.pdfRead the text of UI-Attachment 4a.pdf
UI-Attachment 4b.pdf
PDF · 120 KB · 32 pagesText searchable
Download UI-Attachment 4b.pdfRead the text of UI-Attachment 4b.pdf
UI-Attachment 5.pdf
PDF · 96 KB · 10 pagesText searchable
Download UI-Attachment 5.pdfRead the text of UI-Attachment 5.pdf
UI-Attachment 6.pdf
PDF · 465 KB · 29 pagesText searchable
Download UI-Attachment 6.pdfRead the text of UI-Attachment 6.pdf
UI-Attachment 7.pdf
PDF · 288 KB · 33 pagesText searchable
Download UI-Attachment 7.pdfRead the text of UI-Attachment 7.pdf
UI-Attachment 9.pdf
PDF · 694 KB · 14 pagesText searchable
Download UI-Attachment 9.pdfRead the text of UI-Attachment 9.pdf
UI-Attachment 11.pdf
PDF · 162 KB · 4 pagesText searchable
Download UI-Attachment 11.pdfRead the text of UI-Attachment 11.pdf
UI-Attachment 12.pdf
PDF · 652 KB · 36 pagesText searchable
Download UI-Attachment 12.pdfRead the text of UI-Attachment 12.pdf
Text of ES-Attachment 2b 2026 TDRP-Appendix 8.pdf
Extracted from the file · 23 pages · 37,559 characters
Text of ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ES-Attachment 3.pdf
Extracted from the file · 1 page · 7,205 characters
Text of ES-Attachment 3.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ES-Attachment 4.pdf
Extracted from the file · 44 pages · 108,591 characters
Text of ES-Attachment 4.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ES-Attachment 5.pdf
Extracted from the file · 30 pages · 79,263 characters
Text of ES-Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Text of ES-Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Text of UI-Attachment 1.pdf
Extracted from the file · 176 pages · 247,894 characters
Text of UI-Attachment 2.pdf
Extracted from the file · 108 pages · 171,300 characters
Page 16 of 79
Where UI facilities are already in place, residential overhead service drops are typically designed and located by the customer’s licensed electrical contractor. This includes temporary services to construction trailers that meet the above criteria (the standard flat rate fee for temporary service applies). Upon receiving complete information, UI will provide a job number immediately from our Customer Care Representative or by the next business day if you faxed in your request. Customer Electricians or trained field technicians are expected to determine the proper location for the service based on guidebook standards #1, 2, 3, 4, 10 and 12. If you have requested UI to “spot the service,” then typically you will be contacted within five business days by the Standard Field Department. Midspan service taps are nonstandard construction and generally not acceptable. Contact UI Engineering for other options. 4.3 All Other Service Drops & Laterals The following are requirements for all other overhead service drops and underground service laterals, services where additional poles and wires are needed, all residential overhead services over 200 A, all underground services and all commercial/ industrial services: A. One complete set of an approved A2 survey plot plan showing topography, wetlands (if any), proposed location of other utilities, drainage, property boundaries, roads, sidewalks, driveways, location of buildings and desired service location. Street and property lines must be clearly and accurately marked at the project site. B. A completed UI electrical load information form. C. Construction start and completion dates. You will not receive the UI job number until your request has been reviewed and the job requirements determined by the UI Engineering Department. Typically, you will be contacted by our engineer to discuss the job and/or arrange for a job site meeting within five business days of placing the order. The job requirements will be written by our engineer and sent to you with a copy of the service order by US mail or email. Refer to Guidebook Standards #5, 6, 7, 8, 9, 11 and 13 in Section 13. 13Page 17 of 79
4.4 Residential Developments Overhead line extensions and Underground Residential Distribution (URD) projects require more information, drawings and advance planning. Therefore, it is important that our Engineering Department obtain the following information: A. One complete set of an approved A2 survey plot plan showing topography, wetlands (if any), proposed location of other utilities, drainage, property boundaries, roads, sidewalks, driveways, location of buildings and desired service location. Street and property lines must be clearly and accurately marked at the project site. B. Name of real property owner and the approximate date property was purchased (obtain volume number, page number and date recorded, if available). C. Sizes (sq. ft.) and number of buildings, including the number of units per building and any house meters, if applicable. If this represents only a portion or section of the total development, indicate the total number of future buildings and units planned for the development. D. A completed UI electrical load information form for a typical unit or building. E. Construction start and completion dates. UI needs six to eight weeks after receipt of complete information to prepare the necessary project documents and cannot install or energize any facilities until the necessary contracts are signed and all applicable easements have been recorded on the land records. These documents include: A. As-Planned Engineering Drawing with proposed UI facilities. B. As-Planned Easement Drawing with proposed easement strip. C. Responsibility Agreement/URD Contract. 14Page 18 of 79
4.5 Commercial & Industrial Developments Commercial and industrial developments supplied by overhead power lines or underground cable systems require additional information, drawings and advance planning. Therefore, it is important that our Engineering Department obtain the following information: A. One complete set of an approved A2 survey plot plan showing topography, wetlands (if any), proposed location of other utilities, drainage, property boundaries, roads, sidewalks, driveways, location of buildings and desired service location. Street and property lines must be clearly and accurately marked at the project site. B. One complete set of the electrical series drawings, including the power riser or one-line diagram for the service(s), and any other drawings that detail trenching and conduit placement, transformer foundations, or other items relating to the service from UI’s facilities to the customer’s service entrance equipment. C. Name of real property owner and the approximate date property was purchased (obtain volume number, page number and date recorded, if available). D. Sizes (sq. ft.) and number of buildings, including the number of units per building and any house meters, if applicable. If this represents only a portion or section of the total development, indicate the total number of future buildings and units planned for the development. E. A completed UI electrical load information form for each service. F. Construction start and completion dates. UI needs six to eight weeks after receipt of complete information to prepare the necessary project documents and cannot install or energize any facilities until the necessary contracts are signed and all applicable easements have been recorded on the land records. These documents include: A. As-Planned Engineering Drawing with proposed UI facilities. B. As-Planned Easement Drawing with proposed easement strip. C. Responsibility Agreement /OP-D32 Contract. 15Page 19 of 79
4.6 Service Request Dos and Don’ts REMEMBER: Do: Contact UI’s Customer Care Center to apply for electric service and provide complete and accurate information. Please allow sufficient time for UI to review your request, order necessary materials and schedule the required work. Label meter provisions and main switches with the same identifying mark as the unit the meter serves. Have the authority having jurisdiction inspect and release the service (new or renovated) and notify UI of such release. Install meter provisions outside. Don’t: Install electric service without first applying for service and obtaining the job requirements and a job number from UI. Excavate underground facilities before contacting Call Before You Dig at 811 or [phone removed]. Install meter provisions indoors. Install service conduits to poles until such poles have been approved by UI and the location of the conduit has been clearly marked on the pole. Install more than one 10-foot vertical section of conduit or any service entrance conductors in conduits to poles, padmount transformers or hand holes without coordinating the installation with UI. 5. DESIGN CRITERIA & CONSTRUCTION PRACTICES 5.1 Overhead and Underground Services A. Overhead Service Drops 1. Overhead service drops are installed, owned and maintained by the company. A clear path, devoid of vegetation, is required. Customer is responsible to maintain this clear path. 2. Overhead service drops must not exceed 150 feet in length. 16Page 20 of 79
3. The point of attachment on the customer’s premises will be approved by the company and shall be the shortest practical distance from the company’s pole. Service bolts will be supplied by the company (see Section 12 to find the locations where service bolts are available) and installed by the customer. The bolt shall be adequately anchored at the point of attachment to safely withstand the strain imposed by the service drop. The service bolt must be installed in such a manner that it can withstand at least 650 pounds. of tension. The contractor should install the bolt into brick, concrete block or masonry construction when available. 4. The point of attachment shall be safely accessible by UI crews from a ladder on level ground, and the height above finished grade shall not be less than 12 feet nor more than 26 feet. The point of attachment shall also be such that the minimum conductor clearances conform to NEC 230.24. Attachment height must allow for 12 inches of separation between any communication cable and the service conductor along the length of the cable run. NOTE: If the height of a structure is not adequate to maintain these clearances, a service mast may be necessary. Refer to Guidebook Standards #1, 2, 3 and 4 in Section 13. 5. The point of attachment shall be designated such that UI’s service drop is not readily accessible as defined by the National Electrical Code and the National Electrical Safety Code and adequate horizontal and vertical clearance can be maintained. In no case shall UI provide, own or maintain a service drop that runs horizontally along the surface of a building. 6. Service entrance conductors provided by the customer shall conform to the National Electrical Code and the local authority having jurisdiction and shall be properly identified. 7. If allowed by the local authority having jurisdiction, a maximum of two service masts with a total of six-wires for single-phase or eight-wires for three-phase can be connected to a single service drop. B. Underground Service Laterals 1. Underground service laterals (both the conduit and the service entrance conductors) are supplied, owned and maintained by the customer from the service entrance equipment to the designated point of attachment to UI facilities. 17Page 21 of 79
2. Trenching for underground laterals from wood poles shall not start until the service location is approved and the conduit location is marked at the pole by UI. A maximum of two risers for the electric service can be installed on the pole, and a maximum of three wires for single-phase and four wires for three-phase can be installed in each conduit. While allowed by NEC, UI does not allow multiple sets of conductors in a single conduit. The contractor installs only the first ten-foot vertical length of conduit and one stand-off bracket (a minimum of eight feet above final grade). The conduit must be installed per Guidebook Standard #24 with the conduit being installed away from the flow of traffic and three inches from the pole. The additional conduit, stand-off brackets, weatherhead and UL listed conduit grounding clamp or ground lug kit on the weatherhead are provided by the customer and installed by UI. The riser conduit and elbow at the pole must be rigid galvanized steel. To facilitate the installation of the wires, UI recommends that the elbow at the pole be larger than the minimum allowable radius for the trade diameter conduit being installed. 3. Conduit from the service entrance equipment back to the property line can be either rigid galvanized steel or PVC, subject to the requirements of the NEC and the authority having jurisdiction. Conduit in the street right-of-way (curb to property line) must be rigid galvanized steel. 4. For underground services from single-phase padmount transformers or secondary hand holes, the contractor must locate and extend the PVC conduit stub at the UI point of service connection. If no stub is available, contact UI’s Engineering Department for assistance. Do not attempt to install any conduit or cable into the transformer or hand hole without contacting UI. 5. Direct buried services must extend in rigid galvanized steel conduit from the pole onto private property or extend five feet in Schedule 40 PVC conduit from the single-phase padmount transformer or hand hole. The conduit at the service entrance must extend perpendicularly away from the building foundation wall a minimum of five feet. NOTE: UI does not recommend the installation of direct buried services. 6. Service entrance conductors from poles, padmount transformers or hand holes must be continuous to the meter location. Pull boxes or tap boxes are prohibited except when located next to and installed as part of the service entrance equipment. 18Page 22 of 79
7. Protection from ground movement for underground service entrance conductors shall be provided by the installation of a UL listed slip fitting at all meter provisions. The slip joint shall be the appropriate match to the trade diameter of the service conduit and be securely fastened to the building with a minimum of two clamps. Refer to Guidebook Standard #13 in Section 13. Upon pre-approval in writing from the company, specific applications may be authorized to use flexible metal conduit in place of a slip joint. 8. Our Standard Field Department will schedule the installation and connection of your underground service entrance conductors. You will be contacted after the authority having jurisdiction has inspected the service and the release is posted in our system. 5.2 Road Crossing Poles The company will make every effort to treat all customers equally, no matter which side of the street they reside on. UI will therefore install road crossing poles as follows: A. The company will install overhead secondary service from a pole on the street provided the span does not exceed 150 feet. (100 feet for 400 A services). If the pole is on the opposite side of the street and the service would be within the 150 feet limitation if the pole was on the other side of the street, then a road crossing pole will be set at no cost. If additional poles beyond the road crossing pole are required to reach the building, they will be installed by the company on a billable basis and are covered under UI’s Private Line Pole Policy. Refer to Section 5.3 below and to Guidebook Standard #5 in Section 13. B. If the customer elects to install underground service, UI will install a road crossing pole at no charge to save the customer the cost of trenching across the street. If the customer elects not to have the pole installed, no credit for said pole would be granted by UI. Refer to Guidebook Standard #6 in Section 13. C. The company will install one section of wire, at no charge, from a street pole on the customer’s side of the street. If the street pole line is located on the opposite side of the street, the company will install a pole on the customer’s side of the street, if necessary, and the previously mentioned section of wire will be installed from that pole at no charge. Refer to Guidebook Standard #7 in Section 13. 19Page 23 of 79
5.3 Private Line Poles (PLP) A. Where off-street overhead facilities for a single customer are required, all facilities beyond the standard 150-foot span of overhead wire are billable to the customer. The company will install, own and maintain the overhead facilities. The property owner must sign a Private Property Permit or permanent easement. Future changes to or relocations of these facilities requested by the customer are also billable. B. Where off-street overhead facilities for multiple customers are required, the company will install, own and maintain the overhead facilities. These facilities will be installed at no cost to the customers. A permanent easement must be granted to UI by the property owner(s). Future changes to or relocations of these facilities requested by the customer are billable. C. When company-owned poles are installed on private property, permanent truck access to all poles must be provided and maintained by the property owner. 5.4 Cut & Reconnect Policy POLICY DESCRIPTION: The United Illuminating Company will permit electrical contractors and electricians (herein jointly called “electricians”), licensed by the State of Connecticut, to cut and reconnect residential services at the weatherhead in order to expedite work requested by customers. Failure to follow the steps contained within the procedure of this policy may result in additional corrective work and expense for the electrician. The electrician will be billed for any corrective work performed by the company. Unauthorized connections to the company’s service conductors will be treated as tampering and may result in criminal prosecution. The electrician shall be responsible for obtaining the appropriate permits from the local municipal authority. Homeowners are not authorized to cut and reconnect electric services. Homeowners can only install de-energized or dead services. To participate in the program, an electrician must hold an E-1or E-9 license issued by the Connecticut Electrical Work Examining Board or work in the capacity of an E-2 Journeyman or electrical apprentice under the employment of an E-1 licensee. Under this condition, physical work may be performed; however, the permit must be obtained by the licensee who is responsible for the work at the location. 20Page 24 of 79
The electrician, its employees and those under its control shall perform all work as independent contractors and shall not be deemed to be employees or agents of United Illuminating for any purpose whatsoever. UI shall not be liable for direct, indirect or consequential damages of any kind, whether resulting from injuries to persons or property or otherwise arising out of the electrician’s work. SCOPE OF WORK: Services to be cut and reconnected must meet the following criteria: – Single-phase, overhead service drop, 200 A class (maximum) with voltages of 120V line to ground. – UI requires permanent connections, which will be inspected by UI in order to reduce customer damage due to poor connections. PROCEDURE: The electrician shall perform the following: 1. The electrician shall contact the company at [phone removed] prior to starting work to avoid possible code violations or non-compliance with company requirements. A service location request can also be submitted online at uinet.com. NOTE: In the remarks section, This Work Involves Cut and Reconnect, the work must be completed within 15 days from the required service date. 2. The electrician shall cut the drip loop at the house, on the line side, immediately adjacent to the company’s existing connectors. 3. The electrician shall replace/repair the service entrance/meter box up to the first disconnecting device. 4. The electrician shall connect the replaced or repaired service entrance/meter box to the live ends of the company’s service drop using properly sized connector types as outlined below: – Phase/hot leg: Insulation Piercing Connectors – Neutral: Parallel Groove Connectors – Connectors must be approved for use with the type (copper/aluminum) of conductors being installed. NOTE: Split bolt and taped connectors are not acceptable for permanent connections. 5. The electrician shall install approved rated jumpers and optically clear meter socket cover(s) to avoid damage to the meter socket, ensure public safety and provide access for visual inspection. Covers and service bolts are available through the local building official’s office or from UI. Jumpers may be obtained at UI’s Operations Center located at 100 Marsh Hill Rd., Orange, CT. 21Page 25 of 79
6. The electrician shall leave the old meter in close proximity to the new meter socket. In no case shall the electric meter be reinstalled. 7. The electrician shall be responsible for obtaining municipal inspection/ approval and shall advise the company within one business day of completing Steps 1-6 above. 8. The company shall ensure that the installation meets company requirements and install the necessary meters. 9. Service requests older than six months that have not been completed may be canceled. Contractors may be required to request service again and be issued a new job number. It is the responsibility of the contractor to inform local jurisdiction of this change. VIOLATIONS: In any instance of deviation from the above procedure: 1. The company will bill the electrician for de-energizing meters without an active service request. Any time a meter is de-energized without authorization, our automated systems may dispatch company personnel to the outage. 2. The company will send written notification to the electrician and the municipal authority, describing the specific violation of this policy. This notification will serve as a warning. 3. The company will bill the electrician for costs incurred by the company due to the violation. 4. The company will notify the appropriate municipal and state authorities after multiple warning letters have been issued. This constitutes a violation letter. 5. The company will suspend the electrician’s privilege to participate in the Residential Overhead Service Policy, which includes the Cut and Reconnect Policy. 6. The Trade Practice Division of the Department of Consumer Protection of the State of Connecticut will review complaints to determine if Connecticut General Statute Section 20-334 has been violated and take appropriate action, up to and including penalties, as described in the Connecticut General Statute Section 20-341. 22
Text of UI-Attachment 4a.pdf
Extracted from the file · 60 pages · 136,974 characters
Text of UI-Attachment 4b.pdf
Extracted from the file · 32 pages · 73,024 characters
Text of UI-Attachment 5.pdf
Extracted from the file · 10 pages · 12,154 characters
Text of UI-Attachment 6.pdf
Extracted from the file · 29 pages · 55,721 characters
Text of UI-Attachment 7.pdf
Extracted from the file · 33 pages · 83,950 characters
Text of UI-Attachment 9.pdf
Extracted from the file · 14 pages · 33,843 characters
Text of UI-Attachment 11.pdf
Extracted from the file · 4 pages · 13,890 characters
Text of UI-Attachment 12.pdf
Extracted from the file · 36 pages, 2 without text · 106,019 characters
As listed on the current system
Compliance Filings, 10/01/2026 [26-08-07] Order No.No 4 in docket 17-12-03RE05 / Eversource Energy /