Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Compliance Filing

Compliance Filing, Order No. No

Compliance filingFiled by Eversource Energy24 files
Part of docket 26-08-07Open
  • Electric
Innovative Energy Solutions Program Cycle 5

Files24

Search terms highlighted
Eversource rate increase is on 5 pages across 2 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
2 pages match
Words on different pages

Text of ES-Attachment 2b 2026 TDRP-Appendix 8.pdf

Extracted from the file · 23 pages · 37,559 characters

Text of ES-Attachment 2b 2026 TDRP-Appendix 8.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES-Attachment 3.pdf

Extracted from the file · 1 page · 7,205 characters

Text of ES-Attachment 3.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES-Attachment 4.pdf

Extracted from the file · 44 pages · 108,591 characters

Text of ES-Attachment 4.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES-Attachment 5.pdf

Extracted from the file · 30 pages · 79,263 characters

Words on different pagesRead the text of ES-Attachment 5.pdf

Text of ES-Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of ES-Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of UI-Attachment 1.pdf

Extracted from the file · 176 pages · 247,894 characters

Words on different pagesRead the text of UI-Attachment 1.pdf

Text of UI-Attachment 2.pdf

Extracted from the file · 108 pages · 171,300 characters

Words on different pages
  1. Page 4 of 79

    1. GENERAL INFORMATION 1.1 Introduction This Guidebook provides a cursory view of the policies and procedures of UI and is intended for use by our customers, electrical contractors, consulting engineers, architects and electrical inspectors. We present this Guidebook in an effort to acquaint you with the various types of electric services that are offered by UI and to help you determine which is best suited for your individual needs. This booklet mainly deals with low voltage services (480 volts and below). Primary service voltages above 480 volts are supplied by special contract, and additional information is available on request. We at UI look forward to working with you to meet all your electrical energy and service requirements. NOTE: Section 10.3 contains a list of attributes, characteristics and specifications for approved metering equipment. UI no longer specifies catalog numbers. 1.2 Policies & Procedures UI supplies electricity subject to our Terms and Conditions and our Rate Schedules on file with the Connecticut Public Utilities Regulatory Authority (PURA). While our policies and procedures follow accepted industry practices and standards, they are not necessarily the same as the requirements adopted by the other electric utilities that adjoin our territory. UI policies and procedures are available upon written request and online. Where UI and other specified agencies are named in this book, all policies and requirements are to remain valid for future names of the same entity. 1.3 Safety A. The safety of UI personnel and others who work on and/or around our equipment, as well as the safety of the general public, is our most important concern. Do not approach any downed or exposed wire, cable or other equipment as any contact may cause injury or death. Please report any problems immediately to UI at [phone removed]. B. UI designs, builds and operates its electric system in accordance with the applicable Connecticut General Statutes, Occupational Safety & Health Administration (OSHA) regulations, the National Electrical Safety Code (NESC) and to UI’s own safety rules. Only authorized personnel are allowed to work on utility poles and equipment. 1
  2. Page 5 of 79

    C.  UI reserves the right to refuse to energize a new service or to de-energize an existing service that violates UI safety rules regardless of whether it meets electrical or building codes. D. People working with equipment such as ladders, scaffolding, backhoes, dump trucks, cranes, etc. should use extreme caution when working near UI power lines. Contact with these lines may result in the electrification of you and/or your equipment and may cause injury or death. Please maintain a minimum of 10 feet from UI power lines. For additional information, please refer to OSHA regulations and contact UI at [phone removed]. E. People doing any excavation near buried power cables should use extreme caution. State law requires that you contact CALL BEFORE YOU DIG at 811 or [phone removed] a minimum of two full business days before starting any excavation. 1.4 Electrical Codes A. UI designs, builds and operates its electric system in accordance with the latest revision of the National Electrical Safety Code (NESC). The requirements of this code are incorporated in our Company Standards. For new construction and renovations, certain customer-owned facilities fall under the jurisdiction of the NESC and must also comply with this code. B. Customer-owned facilities are built in accordance with the latest approved version of the National Electrical Code (NEC) and the latest versions of the Building and Fire Safety Codes that have been adopted by the State of Connecticut Department of Public Safety. Approval by the authority having jurisdiction must be received by UI and posted in our system before any new or renovated or substantially repaired electric service can be energized. C. Where there is a conflict with the requirements of UI, the NESC and the NEC, the more stringent requirements shall prevail. If necessary, UI and the authority having jurisdiction will jointly confer. UI reserves the right to make all final determinations. 2
  3. Page 6 of 79

    1.5 Effective Date & Revisions The effective date of this booklet is Dec. 1, 2018, and supersedes all previous issues. All construction started on or after this date must comply with these requirements. Allowance will be made for projects currently in construction or service requests previously submitted to UI. UI reserves the right to change the requirements of the booklet without notification based on changes to our policies and procedures, terms and conditions, industry standards and codes, etc. When planning a project, it is your responsibility to verify the latest requirements of UI. NOTE: Do not start any project without first consulting with UI and the Building Department of your municipality. 1.6 Consultation It is impractical for a booklet of this type to contain all the information necessary to cover all variations and possibilities of service installation. Our Customer Care Center Representatives are available to assist you in determining the appropriate method of service for your needs. Our Customer Care Center acts as a clearinghouse for all customer requests and will direct your questions to the appropriate department. We urge you to contact them at your earliest convenience. We are confident that doing so will result in greater satisfaction and will avoid unnecessary delays. Our Standard Field Department is responsible for coordinating all 200 A and below, single-phase, overhead services for residential customers where UI facilities are already in place. This includes temporary services to construction trailers that meet the above criteria. In addition, Standard Field is responsible for coordinating all service removals for building demolitions. Our Engineering Department is responsible for coordinating all services where additional poles and wires are needed, all residential overhead services over 200 A, all underground residential services and all commercial/industrial services. Our Distributed Energy Resources Department facilitates the safe, reliable interconnections of parallel generation on the distribution system. Our Economic Development Department is available to assist you with the attraction, retention and/or expansion of your business in our service territory. This includes coordinating contact with state and municipal representatives, real estate developers and financial institutions. 3
  4. Page 7 of 79

    Our Energy Conservation Department offers technical assistance, consulting services and incentives at every phase of your construction or retrofit project encouraging the design, construction and operation of energy-efficient buildings and equipment. This assistance covers the major energy-consuming systems such as lighting, heating ventilation and air conditioning equipment (HVAC), refrigeration equipment, motors, air compressors, process equipment and building envelopes. Below are the phone and fax numbers for the listed departments: DEPARTMENT Customer Care Center PHONE # FAX # [phone removed] [phone removed] Email: [email removed] Standard Field [phone removed] [phone removed] Engineering [phone removed] [phone removed] Economic Development [phone removed] [phone removed] Distributed Energy Resources [phone removed] Email: [email removed] Energy Conservation [phone removed] [phone removed] Refer to Section 4, Request for Electric Service for detailed information about applying for service, or visit us on our website at uinet.com. 2. GENERAL REQUIREMENTS FOR SERVICE A. All requests for new service and changes to existing services must be ordered through our Customer Care Center either by phone, fax or the Internet. Call [phone removed] from 7 a.m. to 7 p.m. Monday through Friday and 7 a.m. to 4 p.m. on Saturday. You can fax your Electric Service Information Form to 888.442.-6070 or apply on the Internet at uinet.com at any time. A UI job number will be assigned; this number is required to obtain a release from the authority having jurisdiction. NOTE: Any request for new service or changes to existing service jobs which have no action for 180 days will be canceled, and the request process, if needed, will have to be repeated. B. All service requests must include the name and address of the party who will be responsible for paying the electric bill. The customer may be required to sign a Service Contract and, in some cases, make a deposit. 4
  5. Page 8 of 79

    C. All service requests are subject to UI approval. This includes the service location, voltage and phase characteristics, outdoor meter location and configuration, and other associated requirements. NOTE: ALL new and renovated meter provisions MUST be located outdoors unless approved in writing. Do not purchase any equipment or proceed with any construction until you have obtained these requirements from UI in writing. To avoid problems and delays, this should be done early in the project planning stages. D. In general, service to a customer’s premises will be delivered at a single point. If the capacity requirements to a single building or multiple buildings on a single parcel of land warrant additional service, both UI and the authority having jurisdiction must jointly grant approval. UI reserves the right to restrict the service to a single point of delivery or require additional payment for the cost to provide the additional service. E. When requested by UI: customers consultants or contractors shall complete a UI Load Information Form. This form provides greater details about the project (including the total connected load in kilowatts) and should be submitted to the Engineering Department. It augments and does not replace the service order placed through our Customer Care Center (see Paragraph A above). F. The characteristics of certain electrical equipment such as motors, inverter-based generators and non-linear loads may adversely affect your service and the operation of UI’s electrical system. All adverse effects on UI’s electrical system caused by customer equipment must be corrected by the customer at the customer’s expense. For additional information, please reference Section 6 – Motors and Section 9 – Quality of Service. This incorporates solar, standby generators or any other alternative power generation methods. G. The company requires clear access to its facilities at all times and reserves the right to enter the customer’s property to inspect, maintain and/or upgrade our equipment without notice. If access into a building is required, UI will make every attempt to do this during normal working hours or will make specific arrangements with the property owner. UI reserves the right to disconnect services as allowed by law. 5
  6. Page 9 of 79

    H. When the estimated expenditures of the company to provide service to a customer’s premises exceed the estimated income to be derived from that service, additional payments by the customer may be required. The company may require the customer to pay, in advance, the estimated cost difference to provide such service or to guarantee a minimum annual payment for a term of years as stated in UI’s Terms and Conditions (CPUCA No. 647, Item 4). I. Customers shall consult the company when contemplating changes in the size or electrical characteristics of their equipment. UI normally sizes its equipment to serve the actual electrical load of the customer and not the full potential load of the customer’s service entrance equipment. UI must be notified of customer load increases in advance and be provided the opportunity to replace its equipment, if necessary, prior to the load increase. Damages to company equipment resulting from unauthorized changes shall be the responsibility of the customer. J. All wiring must comply with the latest approved version of the National Electrical Code and the latest versions of the Building and Fire Safety Codes that have been adopted by the State of Connecticut Department of Public Safety. NOTE: UI will not schedule or energize any new or renovated service unless the release from the authority having jurisdiction is posted in our system. The contractor should make arrangements with the proper authority in advance to avoid delays. 3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service territory of UI. All services are either single-phase, three wire or three-phase, four wire and the neutral conductor must be grounded in accordance with the National Electrical Code. Please contact our Engineering Department to verify that the requested service can be provided by UI prior to making any commitments or ordering any equipment. A. Single-phase, three-wire, 120/240 volt service is generally supplied to all residential customers and is typically available for all customers. B. Single-phase, three-wire, 120/208 volt service is only supplied when singlephase metered service is required and a three-phase 120/208Y volt source is available. Typically, this involves large apartment buildings, a condominium or an office complex, or service in the underground network area. 6
  7. Page 10 of 79

    C. Three-phase, four-wire delta (120/240/240 volt) service may be supplied for commercial and industrial customers provided that the minimum connected three-phase load is 5 KW and the minimum total demand is 10 KW. For pole mounted transformers, the minimum service size is 100 A and the maximum service size is 600 A. This voltage is not available from padmount transformers. D. Three-phase, four-wire wye (120/208Y volt) service may be supplied for large residential projects and for commercial and industrial customers. For polemounted transformers, the minimum service size is 400 A with a minimum demand of 30 KW. For padmount transformers, the minimum service size is 600 A with a minimum demand of 65 KW. E. Three-phase, four-wire wye (277/480Y volt) service may be supplied for large commercial and industrial customers. For pole-mounted and padmount transformers, the minimum service size is 400 A with a minimum demand of 100 KW. F. Three-phase, three-wire delta (240 volt and 480 volt) service is no longer provided. For existing services with either of these voltages, please contact Engineering before planning any changes. Conversion to a three-phase, four-wire service may be required. G. Primary service voltages above 480 volts are supplied by special contract. Contact Engineering for additional information. NOTES: When three-phase service is supplied, every effort should be made to balance the load among all three phases. Three-phase service is not generally supplied for residential use but may be furnished if loads warrant and facilities are available. UI’s Engineering Department shall be consulted prior to making commitments for any such service. 7
  8. Page 11 of 79

    3.2 Single- and Three-Phase Service from Pole-Mounted Transformers Maximum Service Size from Transformers Mounted on Poles Main Switch Size and Equivalent KVA Ratings Maximum Size Main Allowed from Street Pole Off-Street Pole Transformer Capacity Allowed on U.G. by U.G. by Poles Cust. Cust. (Note 1) O.H. (Note 2) O.H. (Note 2) VOLTS 400A 600A 800A 120/240 1φ 3 Wire 96 KVA N/A N/A 100 KVA 400 A 400 A 400 A 400 A 120/240/240 3 φ 4 Wire 166 KVA 250 KVA N/A 300 KVA 400 A 400 A 400 A 400A (10 KW Min. Demand) 600 A No longer available for new services. Contact UI’s Engineering Department 240 3φ 3 Wire before making any additions or changes. 120/208Y/ 3 φ 4 Wire 144 KVA 216 KVA 288 KVA 300 KVA 400 A 400 A 400 A 400 A (30 KW Min. Demand) 600 A 800 A 277/480Y 3 φ 4 Wire (100 KW Min. Demand) 332 KVA N/A N/A 300 KVA (Note 3) (Note 3) 400 A 400 A NOTES: 1. 3 φ 3 wire underground services (240V or 480V) are no longer available. Contact UI’s Engineering Department before making any additions or changes to existing service. 2. Conduit shall be no smaller than 1¼ inch nor larger than 4 inch in diameter. Location on the riser pole shall be designated by UI and is typically on the field side of the pole away from traffic. Do not trench to any pole without first obtaining approval from UI. A maximum of two conduits per pole is allowed for electric service and a maximum of three wires for single-phase and four wires for threephase can be installed in each conduit. While allowed by NEC, UI does not allow doubled conductors in a single riser conduit. All riser pole conduits and sweeps to be rigid galvanized steel conduit and supported 3 inches clear of the pole. Install only the first vertical 10-foot length and provide the remaining conduit, brackets, weatherhead and grounding clamp for installation by UI. Service entrance conductors are supplied by the customer and must extend a minimum of three feet beyond the weatherhead to allow for a drip loop. Do not install conductors without UI assistance. 3. 277/480Y services are not available from street poles (private property poles are required). 8
  9. Page 12 of 79

    3.3 Services from Padmount Transformers A. The design, location, voltages and materials for underground services must be approved by UI prior to making any commitments. Please contact UI’s Engineering Department for more information. B. The company has a residential policy (OP-D36) which states that the developer must provide all trenching required for the electrical system. Also, the developer must supply and install foundations and conduit to UI specifications. UI will then install the primary and secondary electric system. UI requires a permanent easement for this equipment. The customer for each individual lot will supply, install, own and maintain the service entrance cables and conduit. Voltages available are 120/240 volt single-phase and 120/208Y volt three-phase for large multi-unit housing. Contact UI’s Engineering Department for more information. C. The company has a commercial/industrial policy (OP-D32) governing service to office or industrial parks. The developer must provide all trenching required for the electrical system. Also, the developer must supply and install foundations and conduit to UI specifications. UI will then install the electric system necessary to supply the individual lots. UI requires a permanent easement for this equipment. The services to the individual lots are installed under separate contracts. See Paragraph D below. Contact UI’s Engineering Department for more information. D. For service to an individual commercial/industrial lot, the customer must supply, install, own and maintain all primary conduit, transformer foundations and the service entrance conduit and cables. The primary conduit shall be installed from the high voltage supply designated by UI to the transformer foundation per UI specifications. UI will install the primary cable and transformer and make all connections to company-owned equipment. Voltages available are single-phase, three-wire 120/240 volt (800 A max.) and three-phase, four-wire 120/208Y (3,000 A max.) or 277/480Y (2,500 A max.). Contact UI’s Engineering Department for more information. 3.4 Services from Transformer Vaults A. The design, location, voltages and materials for these underground services must be approved by the company prior to making any commitments. Contact UI’s Engineering Department for more information. 9
  10. Page 13 of 79

    B. For downtown New Haven or Bridgeport, the company has a policy (OP-D10N) for service from the network grid. Services up to 800 A at 120/208Y volts will be connected to the grid. The customer must pay for that portion of the service between the main switch or junction box and the curb. Services exceeding 800 A in total capacity at 120/208Y and all services rated 277/480Y cannot be connected directly to the network grid. In this case, the customer is required to install, own and maintain a vault to UI specifications. Voltages available are three-phase, four wire 120/208Y or 277/480Y, and are limited to 3000 A. (Refer to Guidebook Standards #8 and #9 in Section 13.) NOTE: Other municipalities have underground systems in portions of their downtown areas (e.g., East Haven and Derby). Contact UI’s Engineering Department for specific requirements for service in these areas. C. With the exception of single meter installations, the underground service conduit shall terminate in a junction or pull box supplied and installed by the customer. The junction or pull box shall meet both UI and National Electrical Code requirements and is subject to the approval of the authority having jurisdiction. The junction box will connect to the customer’s main switch or switches. The minimum size of the box shall be based on the service size, and the conduit shall enter from the back or the end of the box. The service conductors shall not be spliced but may be tapped where multiple main switches are used. The junction or pull box shall have provisions for company locks and seals. Contact UI’s Engineering Department for drawings of approved junction boxes. D. In each of the above cases, the service entrance disconnect must be either a switch with current limiting fuses or a circuit breaker of equivalent interrupting capacity. The short circuit capacity of these devices shall be not less than 200,000 A symmetrical for downtown network areas, and the service must be configured in cold sequence (i.e., switch-fuse-meter). For all other areas, contact UI’s Engineering Department. E. Customers in non-network areas may be required to install, own and maintain a transformer vault to UI specifications. This occurs when the service entrance capacity requires the installation of transformers on the customer’s property and there is not sufficient area for a padmount transformer. Voltages available are three-phase, four-wire 120/208Y (3,000 A max.) or 277/480Y (2500 A max.). The short circuit capacity of these devices shall be calculated by UI, and the service must be configured in cold sequence (i.e., switch-fuse-meter). Contact UI’s Engineering Department for more information. 10

Text of UI-Attachment 4a.pdf

Extracted from the file · 60 pages · 136,974 characters

Text of UI-Attachment 4b.pdf

Extracted from the file · 32 pages · 73,024 characters

Text of UI-Attachment 5.pdf

Extracted from the file · 10 pages · 12,154 characters

Words on different pagesRead the text of UI-Attachment 5.pdf

Text of UI-Attachment 6.pdf

Extracted from the file · 29 pages · 55,721 characters

Words on different pagesRead the text of UI-Attachment 6.pdf

Text of UI-Attachment 7.pdf

Extracted from the file · 33 pages · 83,950 characters

Words on different pagesRead the text of UI-Attachment 7.pdf

Text of UI-Attachment 9.pdf

Extracted from the file · 14 pages · 33,843 characters

Words on different pagesRead the text of UI-Attachment 9.pdf

Text of UI-Attachment 11.pdf

Extracted from the file · 4 pages · 13,890 characters

Text of UI-Attachment 12.pdf

Extracted from the file · 36 pages, 2 without text · 106,019 characters

As listed on the current system

Compliance Filings, 10/01/2026 [26-08-07] Order No.No 4 in docket 17-12-03RE05 / Eversource Energy /