Interrogatory responses
Answers to questions 4, 5
Filed by Connecticut Light and Power Company dba Eversource Energy4 files
Part of docket 26-05-10Files4
CLF-AC-004_Final.pdf
PDF · 132 KB · 3 pagesText searchable
Download CLF-AC-004_Final.pdfRead the text of CLF-AC-004_Final.pdf
CLF-AC-004 Attachment 1.pdf
PDF · 116 KB · 1 pageText searchable
Download CLF-AC-004 Attachment 1.pdfRead the text of CLF-AC-004 Attachment 1.pdf
CLF-AC-004 Attachment 1.xlsx
Excel · 40 KBText searchable
Download CLF-AC-004 Attachment 1.xlsxRead the text of CLF-AC-004 Attachment 1.xlsx
CLF-AC-005_Final.pdf
PDF · 150 KB · 3 pagesText searchable
Download CLF-AC-005_Final.pdfRead the text of CLF-AC-005_Final.pdf
The Connecticut Light and Power Company
d/b/a Eversource Energy
Docket No. 26-05-10
Set CLF-AC-01
Date Issued September 16, 2026
CLF-AC-004
Page 1 of 3
Date Filed: October 07, 2026
Witness:
Douglas P. Horton
Request from: CLF and Acadia Center
Question:
(Performance-based Regulation) Refer to Exhibit CLP-PBR-1, pages 69-71.
(a) Please confirm whether or not the Company’s proposed capital funding mechanism
includes any return on investment (i.e., weighted average cost of capital) on capital
additions during the PBMRP term prior to a prudency determination in a subsequent rate
case.
(b) If the answer to CLF-AC-4(a), is yes, quantify the amount of return on investment included
in the Company’s requested revenue requirement for each Rate Year attributable to capital
additions that have not yet been found prudent. Please provide all workpapers used to
determine this amount.
(c) Explain whether this treatment in CLF-AC-4 (a), and (b), is consistent with the RE01 2025
PFD’s declaration that the CT-Bar “does not include any return on investment ... on the
incremental CT-Bar plant additions (as stated in Docket No. 21-05-15RE01, Proposed
Final Decision, July 2025, at pages 36-37)” until a prudency finding.
Response:
(a) The Company’s proposed F-Factor mechanism provides a revenue allowance that is
appropriately calibrated to support the Company’s cost directly resulting from the system
investments necessary to achieve the performance and clean energy objectives for the state
of Connecticut. The allowance does include revenue to cover the costs of capital, which
are real costs of service, the same as any other. The Company’s proposed F-Factor
provides a revenue allowance based on the calculated revenue requirement established
initially based on the projected capital expenditures for each year of the F-Factor
mechanism established in this proceeding. Under the Company’s proposal, the PBMRP
(inclusive of the F-Factor adjustment) will go into effect annually on July 1 of each year
based on the forecast described above, subject to a downward only reconciliation of capital
investments to the forecasted investment provided in this proceeding. To the extent the
Company does not place into service the level of system investment supported by the FFactor allowance, or in the event that PURA determines any of the actual capital additions
are not prudently incurred and appropriate for recovery, the F-Factor proposal incorporates
a downward-only adjustment to reduce the authorized revenue requirement (i.e., to reflect
the revenue requirement that would have been reflected in the F-Factor, had the reduced
plant in service been reflected in the F-Factor initially) such that any funds owed to
The Connecticut Light and Power Company
d/b/a Eversource Energy
Docket No. 26-05-10
Set CLF-AC-01
Date Issued September 16, 2026
CLF-AC-004
Page 2 of 3
customers would be returned thus ensuring that customers ultimately pay only for the costs
of the capital that enabled the system investment actually in-service. This downward-only
adjustment is in place to ensure that if the Company invests less capital than is initially
reflected in the F-Factor allowance for a given period, or if PURA subsequently disallows
recovery of a project (or projects) such that the actual plant in service is less than that
assumed in the initial F-Factor allowance, customers will not pay more than what is
actually in service and prudently incurred to serve them. Conversely, if the Company
invests more than assumed in the F-Factor allowance, no such upward adjustment is
contemplated to reflect the higher revenue requirement incurred by the Company. No
aspect of the Company’s proposal circumvents prudence reviews or accountability, rather
the Company’s proposal aligns the system investments outlined in the TSP with the
revenues necessary to support those investments, including the cost of capital.
(b) As noted above, the Company does not view the F-Factor as providing a return on
investment prior to PURA’s prudency review of the underlying capital additions, since any
amounts initially included in the F-Factor allowance will ultimately be reconciled to the
customer’s benefit if those costs are ultimately found to be imprudently incurred and thus
not recoverable from customers.
Saying that, the calculation of the F-Factor allowance does include the cost of capital,
including return on equity investment, as described above and elsewhere in this proceeding.
The Company has summarized the return necessary for incremental system investment in
Table 1 below, taken from CLF-AC-004, Attachment 1, Lines 12-14.
Table 1
Return on Incremental Rate Base
Incremental Average Rate Base, $ Millions
Pretax Percentage Return on Rate Base
Pretax Return on Rate Base, $ Millions
Rate Year 1
7/1/2027
$346
9.04%
$31
Rate Year 2
7/1/2028
$353
9.04%
$32
Rate Year 3
7/1/2029
$376
9.04%
$34
Rate Year 4
7/1/2030
$400
9.04%
$36
(c) No. As described above, the Company's proposal is intentionally inconsistent on this point
with the CT-Bar approach described in the Docket No. 21-05-15RE01 proposed final
decision.
The CT-Bar construct described in the RE01-PFD excluded recovery of financing costs
associated with incremental system investment, which are essential in the provision of
electric service to customers, until a subsequent prudence determination. The Company's
proposed F-Factor does not adopt that approach because the CT-bar did not reflect the
economic reality that financing costs are incurred when investments are made and placed
in service, not when a future prudence review occurs.
The Connecticut Light and Power Company
d/b/a Eversource Energy
Docket No. 26-05-10
Set CLF-AC-01
Date Issued September 16, 2026
CLF-AC-004
Page 3 of 3
The fundamental flaw in the CT-Bar approach is that it would require the Company to
undertake significant capital investments on behalf of customers while barring recovery of
the financing costs necessary to support those investments. In effect, the utility would be
expected to provide capital for an extended period of time without any underlying means
of sustainably covering the cost of that capital. Such a construct is inconsistent with basic
regulated ratemaking principles, regardless of the framework, and creates a structural
inability to finance sustained investment during a multi-year rate plan.
The Company's proposal recognizes this reality while preserving all customer protections.
The F-Factor includes a downward-only reconciliation mechanism that returns revenues to
customers, with carrying charges, if the Company is unable to place into service the level
of investment forecasted today. PURA also retains its full ability to review the prudence
of utility investments and disallow costs upon a finding of imprudence. Accordingly, the
Company's proposal neither circumvents prudence review nor does it shift risk
inappropriately to customers. Rather, it provides a reasonable mechanism for aligning
revenues with the financing requirements associated with the investments the Company is
expected to make during the PBMRP term.
The distinction between the two approaches is therefore straightforward. The CT-Bar
construct outlined in the RE01-PFD intentionally ignores the unavoidable financing costs
of the system investment necessary to achieve the performance objects of the PBR plan,
whereas the F-Factor recognizes that financing costs are incurred contemporaneously with
the investment activity they support while preserving subsequent prudence review and
customer protections.
As listed on the current system
Question(s) Answered 4, 5 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 10/07/2026