Interrogatory responses
Answers to questions 1, 2, 4, 10, 18, 20
Files13
ICC-001_Final.pdf
PDF · 114 KB · 1 pageText searchable
Download ICC-001_Final.pdfRead the text of ICC-001_Final.pdf
ICC-001 Attachment 1.pdf
PDF · 3.4 MB · 28 pagesText searchable
Download ICC-001 Attachment 1.pdfRead the text of ICC-001 Attachment 1.pdf
ICC 001 Attachment 2.pdf
PDF · 4.0 MB · 68 pagesText searchable
Download ICC 001 Attachment 2.pdfRead the text of ICC 001 Attachment 2.pdf
ICC-001 Attachment 3.pdf
PDF · 1.1 MB · 34 pagesText searchable
Download ICC-001 Attachment 3.pdfRead the text of ICC-001 Attachment 3.pdf
ICC-001 Attachment 4.pdf
PDF · 1.3 MB · 34 pagesText searchable
Download ICC-001 Attachment 4.pdfRead the text of ICC-001 Attachment 4.pdf
ICC-001 Attachment 5.pdf
PDF · 3.5 MB · 67 pagesText searchable
Download ICC-001 Attachment 5.pdfRead the text of ICC-001 Attachment 5.pdf
ICC-002_Final.pdf
PDF · 143 KB · 2 pagesText searchable
Download ICC-002_Final.pdfRead the text of ICC-002_Final.pdf
ICC-002 Attachment 1.pdf
PDF · 1.1 MB · 29 pagesText searchable
Download ICC-002 Attachment 1.pdfRead the text of ICC-002 Attachment 1.pdf
ICC-002 Attachment 2.pdf
PDF · 1.5 MB · 74 pagesText searchable
Download ICC-002 Attachment 2.pdfRead the text of ICC-002 Attachment 2.pdf
ICC-002 Attachment 3.pdf
PDF · 2.5 MB · 27 pagesText searchable
Download ICC-002 Attachment 3.pdfRead the text of ICC-002 Attachment 3.pdf
ICC-004_Final.pdf
PDF · 127 KB · 1 pageText searchable
Download ICC-004_Final.pdfRead the text of ICC-004_Final.pdf
ICC-010_Final.pdf
PDF · 168 KB · 4 pagesText searchable
Download ICC-010_Final.pdfRead the text of ICC-010_Final.pdf
ICC-018_Final.pdf
PDF · 135 KB · 2 pagesText searchable
Download ICC-018_Final.pdfRead the text of ICC-018_Final.pdf
Text of ICC-001 Attachment 3.pdf
Extracted from the file · 34 pages · 76,972 characters
Text of ICC-001 Attachment 4.pdf
Extracted from the file · 34 pages · 72,650 characters
Text of ICC-001 Attachment 5.pdf
Extracted from the file · 67 pages · 136,480 characters
Text of ICC-002_Final.pdf
Extracted from the file · 2 pages · 2,788 characters
Text of ICC-002 Attachment 1.pdf
Extracted from the file · 29 pages · 46,015 characters
Page 35 of 74
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 2 Page 35 of 74 ATTACHMENT I INTERCONNECTION REQUEST Rotor Resistance, Rr: ______________Per Unit Stator Resistance, Rs: ______________ Per Unit Stator Reactance, Xs: ______________Per Unit Rotor Reactance, Xr: ______________ Per Unit Magnetizing Reactance, Xm: ______________Per Unit Short Circuit Reactance, Xd'': ______________Per Unit Exciting Current: ______________Amps Temperature Rise: ______________ Frame Size: ______________ Design Letter: ______________ Reactive Power Required In Vars (No Load): ______________ Reactive Power Required In Vars (Full Load): ______________ Total Rotating Inertia, H: _____________ Per Unit on kVA Base Excitation and Governor System Data for Synchronous Generators Only. Provide appropriate IEEE model block diagram of excitation system, governor system and power system stabilizer (PSS) in accordance with the regional reliability council criteria. A PSS may be determined to be required by applicable studies. A copy of the manufacturer's block diagram may not be substituted. Interconnection Facilities Information An Interconnection transformer is required unless waived by the Interconnecting EDC. Transformer Data (If Applicable, for Generating Facility-Owned Transformer): Is the transformer: ____single phase _____three phase? Size: ___________kVA Transformer Impedance: _______% on __________kVA Base Transformer Positive-Sequence Short Circuit Impedances (pu): Zps= _______, Zpt=_______, Zst=_______ Transformer Zero-Sequence Impedances (pu): ): Zpm0= _______, Zsm0=_______, Zmg0=_______ Transformer Neutral Grounding Reactor/Resistor Impedance (Ohms): Transformer BIL Rating _______kV If Three Phase: Transformer Primary: _____ Volts _____ Delta _____Wye _____ Wye Grounded Transformer Secondary: _____ Volts _____ Delta _____Wye _____ Wye Grounded Transformer Tertiary: _____ Volts _____ Delta _____Wye _____ Wye Grounded Transformer Fuse Data (If Applicable, for Generating Facility-Owned Fuse): I-7Page 36 of 74
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 2 Page 36 of 74 ATTACHMENT I INTERCONNECTION REQUEST (Attach copy of fuse manufacturer's Minimum Melt and Total Clearing Time-Current Curves) Manufacturer: __________________ Type: _______________ Size: ________Speed: ______________ Interconnecting Circuit Breaker (if applicable): Manufacturer: ____________________________ Type: __________ Load Rating (Amps): _______ Interrupting Rating (Amps): ________ Trip Speed (Cycles): __________ Interconnection Protective Relays (If Applicable): If Microprocessor-Controlled: List of Functions and Adjustable Set points for the protective equipment or software: Set point Function Minimum Maximum 1. 2. 3. 4. 5. 6. If Discrete Components: (Enclose Copy of any Proposed Time-Overcurrent Coordination Curves) Manufacturer: Manufacturer: Manufacturer: Type: Type: Type: Style/Catalog No.: Style/Catalog No.: Style/Catalog No.: I-8 Proposed Setting: Proposed Setting: Proposed Setting:Page 37 of 74
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 2 Page 37 of 74 ATTACHMENT I INTERCONNECTION REQUEST Manufacturer: Manufacturer: Type: Type: Style/Catalog No.: Style/Catalog No.: Proposed Setting: Proposed Setting: Current Transformer Data (If Applicable): (Enclose Copy of Manufacturer's Excitation and Ratio Correction Curves) Manufacturer: Type: Accuracy Class: Proposed Ratio Connection: ____ Manufacturer: Type: Accuracy Class: Proposed Ratio Connection: ____ Potential Transformer Data (If Applicable): Manufacturer: Type: Accuracy Class: Proposed Ratio Connection: ____ Manufacturer: Type: Accuracy Class: Proposed Ratio Connection: ____ General Information Enclose two D-sized (24” x 36”) copies of site electrical one-line diagram showing the configuration of all Generating Facility equipment (unless waived by the EDC), current and potential circuits, and protection and control schemes. This D-sized one-line diagram must be signed and stamped by a licensed Professional Engineer if the Generating Facility is larger than 50 kW. Are two copies of One-Line Diagram Enclosed? ____Yes ____No Enclose copy of any site documentation that indicates the precise physical location of the proposed Generating Facility (e.g., USGS topographic map or other diagram or documentation). Proposed location of protective interface equipment on property (include address if different from the Generating Facility's address) _________________________________________________ Enclose copy of any site documentation that describes and details the operation of the protection and control schemes. Is Available Documentation Enclosed? ___Yes ____No Enclose copies of schematic drawings for all protection and control circuits, relay current circuits including CT’s wiring connection and their ratios, relay potential circuits including Potential I-9Page 38 of 74
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 2 Page 38 of 74 ATTACHMENT I INTERCONNECTION REQUEST Transformer’s (PT’s) wiring connection and their ratios, any alarm/monitoring circuits (if applicable). Are Schematic Drawings Enclosed? ___Yes ____No Applicant Signature I have read the Guidelines for Generator Interconnection – Fast Track and Study Processes and agree to abide by all terms and conditions as provided for in theses Guidelines. I understand that my Interconnection Request may be rejected by the Interconnecting EDC or there may be a delay in processing my Interconnection Request if the Interconnecting EDC determines that I have not complied with these Guidelines. I hereby certify that, to the best of my knowledge, all the information provided in this Interconnection Request is true and correct. For Generator: __________________________________________ Date: ____________ I-10Page 39 of 74
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 2 Page 39 of 74 ATTACHMENT II APPLICATION ACKNOWLEDGEMENT RECEIPT-SAMPLE FORM Receipt of Interconnection Application (Eversource Energy/UI Use Only) Generator Name: ______________________ Date Interconnection Request Received: ________________ Received By: ________________________________________ Application Number ______________________ II-1Page 40 of 74
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 2 Page 40 of 74 ATTACHMENT III INFORMATION REQUEST- SAMPLE FORM Missing Application Information (Eversource Energy/UI Use Only) Interconnection Application #: ______________________ Generator Name: ______________________ Missing Elements: Payment Deficient Signed Application One Line Schematic Site Plan Technical Data Insurance Date Cured: __________ Date Cured: __________ Date Cured: __________ Date Cured: __________ Date Cured: __________ Date Cured: __________ Date Deemed Valid Interconnection Request: __________ Deemed Valid By: ____________________________ III-1Page 41 of 74
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 2 Page 41 of 74 ATTACHMENT IV FEASIBILITY STUDY AGREEMENT Feasibility Study Agreement This Feasibility Study Agreement (this “Agreement”), dated as of _______________ (the “Effective Date”), is entered into by and between [Eversource Energy, a Connecticut corporation with a principal place of business at 107 Selden St, Berlin, CT, 06037] [or] [The United Illuminating Company, a specially charted Connecticut corporation with a principal place of business at 180 Marsh Hill Road, Orange, CT 06477] (the “EDC”), and ____________________________________, a ________________________with a principal place of business at _______________________________, _________________________________ (“Generator”). (EDC and Generator are collectively referred to as the “Parties” and individually as a “Party”). RECITALS WHEREAS, Generator is proposing to develop a Generating Facility or increase the generating capacity of an existing Generating Facility consistent with the Interconnection Request completed by Generator on_________________________; WHEREAS, Generator desires to interconnect the Generating Facility with the Distribution System; and WHEREAS, Generator has requested the EDC to perform a Feasibility Study to assess the feasibility of interconnecting the proposed Generating Facility with the facilities that are part of the EDC’s Distribution System, and of any Affected Systems (the “Feasibility Study”). NOW, THEREFORE, in consideration of and subject to the mutual covenants contained herein the Parties agree as follows: 1.0 Capitalized terms used herein but not defined herein shall have the meanings ascribed to such terms in the EDC’s Guidelines for Generator Interconnection (the “Guidelines”). 2.0 The EDC shall conduct a Feasibility Study in accordance with the Guidelines. 3.0 The scope of the Feasibility Study shall be subject to the assumptions set forth in Exhibit A to this Agreement. 4.0 The Feasibility Study shall be based on the technical information provided by the Generator in its Interconnection Request, as may be modified as the result of the Scoping Meeting. At the reasonable request of the EDC, the Generator shall promptly provide additional technical information to the EDC. 5.0 In performing the Feasibility Study, the EDC may rely, to the extent reasonably practicable, on other existing studies in the EDC’s possession. IV-1Page 42 of 74
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 2 Page 42 of 74 ATTACHMENT IV FEASIBILITY STUDY AGREEMENT 6.0 At the request of the Generator and at the Generator’s sole cost and expense, the Feasibility Study shall include the feasibility of any Interconnection at a proposed project site where there could be multiple potential Points of Interconnection. 7.0 In conjunction with the execution of this Agreement, the EDC shall provide to the Generator a written good faith estimate of the cost of the Feasibility Study (the “Cost Estimate”). Prior to commencement of the Feasibility Study, the Generator shall pay the Cost Estimate to the EDC. 8.0 Following the conclusion of the Feasibility Study, the EDC shall prepare a Feasibility Study report (the “Report”), which shall provide the following analyses for the purpose of identifying any potential adverse system impacts that would result from the Interconnection of the Generating Facility as proposed: 8.1 Initial identification of any circuit breaker or other facility short circuit capability limits exceeded as a result of the Interconnection; 8.2 Initial identification of any thermal overload or voltage limit violations resulting from the Interconnection; 8.3 Initial review of grounding requirements and electric system protection; and 8.4 A non-binding estimate of the cost (including a description thereof) of facilities required to interconnect the proposed Generating Facility. 9.0 The EDC shall use commercially reasonable efforts to provide the Report to the Generator within thirty (30) days of the later of (a) execution of this Agreement and (b) payment of the Cost Estimate by the Generator. 10.0 Within thirty (30) days of the completion of the Feasibility Study, the EDC shall calculate the actual costs of the Feasibility Study (the “Actual Cost”), and the EDC shall provide an invoice to the Generator which shall include the Actual Cost and the basis for the calculation of the Actual cost. 11.0 In the event the Actual Cost exceeds the Cost Estimate, the Generator shall pay the difference to the EDC within thirty (30) Calendar Days of the invoice date (without interest). In the event the Cost Estimate exceeds the Actual Cost, the EDC shall pay the excess to the Generator within thirty (30) Calendar Days of the invoice date (without interest). 12.0 Miscellaneous. 12.1 Accuracy of Information. The Generator represents and warrants that, to the best of its knowledge, the information it provides to the EDC in connection with this Agreement and the Feasibility Study shall be accurate and complete as of the date such information is provided. The Generator IV-2Page 43 of 74
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 2 Page 43 of 74 ATTACHMENT IV FEASIBILITY STUDY AGREEMENT shall promptly provide the EDC with any additional information needed to update information previously provided. 12.2 Disclaimer of Warranty. In performing the Feasibility Study, the EDC may rely on information provided by the Generator and third parties, and may not have control over the accuracy of such information. ACCORDINGLY, THE EDC HEREBY EXPRESSLY DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, WHETHER ARISING BY OPERATION OF LAW, COURSE OF PERFORMANCE OR DEALING, CUSTOM, USAGE IN THE TRADE OR PROFESSION, OR OTHERWISE, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Generator acknowledges that it has not relied on any representations or warranties not specifically set forth herein and that no such representations or warranties have formed the basis of its bargain hereunder. 12.3 Force Majeure, Liability and Indemnification. 12.3.1 Force Majeure. If a Force Majeure Event prevents a Party from fulfilling any obligations under this Agreement, such Party will promptly notify the other Party in writing, and will keep the other Party informed on a continuing basis of the scope and duration of the Force Majeure Event. The affected Party shall specify in reasonable detail the circumstances of the Force Majeure Event, its expected duration, and the steps that the affected Party is taking to mitigate the effects of the event on its performance. The affected Party may suspend or modify its performance of obligations under this Agreement, other than the obligation to make payments then due or becoming due under this Agreement, but only to the extent that the effect of the Force Majeure Event cannot be mitigated by the use of commercially reasonable efforts. The affected Party shall use commercially reasonable efforts to resume its performance as soon as possible. Without limiting this section, the Generator shall immediately notify the EDC verbally if the failure to fulfill the Generator's obligations under this Agreement may impact the safety or reliability of the EDC EPS. For purposes of this Agreement, “Force Majeure Event” means any event or circumstance that (a) is beyond the reasonable control of the affected Party and (b) the affected Party is unable to prevent or provide against by exercising commercially reasonable efforts. Force Majeure Events include the following events or circumstances, but only to the extent they satisfy the foregoing requirements: (i) acts of war or terrorism, public disorder, insurrection, or rebellion; (ii) floods, hurricanes, earthquakes, lighting, storms, and other natural calamities; (iii) explosions or fire; (iv) strikes, work stoppages, or labor disputes; (v) IV-3Page 44 of 74
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 2 Page 44 of 74 ATTACHMENT IV FEASIBILITY STUDY AGREEMENT embargoes; and (vi) sabotage. In no event shall the lack of funds or the inability to obtain funds constitute a Force Majeure Event. 12.3.2 Liability. Except with respect to a Party's fraud or willful misconduct, and except with respect to damages sought by a third party in connection with a third party claim: (a) neither Party shall be liable to the other Party, for any damages other than direct damages; and (b) each Party agrees that it is not entitled to recover and agrees to waive any claim with respect to, and will not seek, consequential, punitive or any other special damages as to any matter under, relating to, arising from or connected to this Agreement.. Notwithstanding the foregoing, nothing in this Section 13.3.2 shall be deemed to limit Generator’s obligations under Section 13.3.3. 12.3.3 Indemnification. The Generator shall indemnify, defend and hold harmless the EDC and its trustees, directors, officers, employees and agents (including affiliates, contractors and their employees) from and against any liability, damage, loss, claim, demand, complaint, suit, proceeding, action, audit, investigation, obligation, cost, judgment, adjudication, arbitration decision, penalty (including fees and fines), or expense (including court costs and attorneys' fees) relating to, arising from or connected to this Agreement. 12.4 Term and Termination. This Agreement shall be effective from the Effective Date until the earlier of (a) one year from the Effective Date and (b) the withdrawal of the Generator’s Interconnection Request, unless extended by written agreement of the Parties. Notwithstanding the foregoing, the EDC may terminate this Agreement fifteen (15) days after providing written notice to the Generator that it has breached any of its obligations hereunder, if such breach has not been cured within such fifteen (15) day period. 12.5 Governing Law. This Agreement shall be governed by and construed in accordance with the laws of the State of Connecticut applicable to contracts made and performed in such State and without regard to conflicts of law doctrines. 12.6 Severability. If any provision of this Agreement is held to be unenforceable for any reason, such provision shall be adjusted rather than voided, if possible, to achieve the intent of the Parties. If no such adjustment is possible, such provision shall be fully severable and severed, and all other provisions of this Agreement will be deemed valid and enforceable to the extent possible. 12.7 Counterparts. This Agreement may be executed in counterparts, each of which shall be deemed an original, and all counterparts so executed shall constitute one agreement binding on all of the Parties hereto, IV-4
Text of ICC-002 Attachment 3.pdf
Extracted from the file · 27 pages · 91,051 characters
Text of ICC-004_Final.pdf
Extracted from the file · 1 page · 983 characters
Text of ICC-010_Final.pdf
Extracted from the file · 4 pages · 11,507 characters
Text of ICC-018_Final.pdf
Extracted from the file · 2 pages · 2,628 characters
As listed on the current system
Question(s) Answered 1, 2, 4, 10, 18, 20 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 09/22/2026