Interrogatory responses
Answers to questions 1, 2, 4, 10, 18, 20
Files13
ICC-001_Final.pdf
PDF · 114 KB · 1 pageText searchable
Download ICC-001_Final.pdfRead the text of ICC-001_Final.pdf
ICC-001 Attachment 1.pdf
PDF · 3.4 MB · 28 pagesText searchable
Download ICC-001 Attachment 1.pdfRead the text of ICC-001 Attachment 1.pdf
ICC 001 Attachment 2.pdf
PDF · 4.0 MB · 68 pagesText searchable
Download ICC 001 Attachment 2.pdfRead the text of ICC 001 Attachment 2.pdf
ICC-001 Attachment 3.pdf
PDF · 1.1 MB · 34 pagesText searchable
Download ICC-001 Attachment 3.pdfRead the text of ICC-001 Attachment 3.pdf
ICC-001 Attachment 4.pdf
PDF · 1.3 MB · 34 pagesText searchable
Download ICC-001 Attachment 4.pdfRead the text of ICC-001 Attachment 4.pdf
ICC-001 Attachment 5.pdf
PDF · 3.5 MB · 67 pagesText searchable
Download ICC-001 Attachment 5.pdfRead the text of ICC-001 Attachment 5.pdf
ICC-002_Final.pdf
PDF · 143 KB · 2 pagesText searchable
Download ICC-002_Final.pdfRead the text of ICC-002_Final.pdf
ICC-002 Attachment 1.pdf
PDF · 1.1 MB · 29 pagesText searchable
Download ICC-002 Attachment 1.pdfRead the text of ICC-002 Attachment 1.pdf
ICC-002 Attachment 2.pdf
PDF · 1.5 MB · 74 pagesText searchable
Download ICC-002 Attachment 2.pdfRead the text of ICC-002 Attachment 2.pdf
ICC-002 Attachment 3.pdf
PDF · 2.5 MB · 27 pagesText searchable
Download ICC-002 Attachment 3.pdfRead the text of ICC-002 Attachment 3.pdf
ICC-004_Final.pdf
PDF · 127 KB · 1 pageText searchable
Download ICC-004_Final.pdfRead the text of ICC-004_Final.pdf
ICC-010_Final.pdf
PDF · 168 KB · 4 pagesText searchable
Download ICC-010_Final.pdfRead the text of ICC-010_Final.pdf
ICC-018_Final.pdf
PDF · 135 KB · 2 pagesText searchable
Download ICC-018_Final.pdfRead the text of ICC-018_Final.pdf
Text of ICC-001 Attachment 3.pdf
Extracted from the file · 34 pages · 76,972 characters
Text of ICC-001 Attachment 4.pdf
Extracted from the file · 34 pages · 72,650 characters
Text of ICC-001 Attachment 5.pdf
Extracted from the file · 67 pages · 136,480 characters
Text of ICC-002_Final.pdf
Extracted from the file · 2 pages · 2,788 characters
Page 20 of 29
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 1 Page 20 of 29 20 Eversource - Internal UsePage 21 of 29
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 1 Page 21 of 29 INTERCONNECTION APPLICATION Interconnection Customer (EDC Customer of Record) Customer of Record: _ __________________________________________ Contact Person: Facility Address: City: State: Telephone (Day): (Evening): Fax: E-Mail Address: Zip: Account Number: Meter Number: *Authorized Agent Company Name: Contact: Address: City: State: Telephone (Day): (Evening): Fax: E-Mail Address: Zip: *If Authorized Agent fields are entered, please complete the Agent Authorization Form. Ownership Information (Owner of the Generating facility): Company Name: Contact: Address: City: State: Telephone (Day): (Evening): Fax: E-Mail Address: 21 Eversource - Internal Use Zip:Page 22 of 29
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 1 Page 22 of 29 APPLICATION IS FOR: Is this a new service? New Generating Facility? If No, please describe: Yes ___No ___ Yes ___No ___ Is the Interconnection Request for: Net Metering? Yes ___No ___ If No, please describe: Nameplate Rating (Nominal): System Design Capacity (AC): _________ (kW) _______ (kVA) Single Phase _______ Three Phase Battery Backup? Yes _____ No ______ Inverter Manufacturer 1. 2. 3. Model Quantity New or Existing Is the equipment UL1741 SA Listed? Yes____ No ____ Prime Mover: Photovoltaic Fuel Cell Energy Source: Reciprocating Engine Solar Turbine Diesel Other Wind Hydro Natural Gas Fuel Oil Other __________________________ Interconnection Customer Signature I hereby certify that, to the best of my knowledge, the information provided in this Application is true. I agree and accept all terms and conditions for Interconnection and agree to abide by the “Guidelines for Interconnection of Single Phase Certified Inverter-Based Generating Facilities of 20 kW (AC) or Less” to interconnect a Certified Inverter-Based Generating Facility and return the Certificate of Completion when the Certified Inverter-Based Generating Facility has been installed Signed: ___________________________________ Date: __________ Print Name: __________________________________________________ NOTE: Facsimile or electronic (e.g., .pdf) execution and delivery of this Interconnection Application is legal, valid and binding for all purposes. 22 Eversource - Internal UsePage 23 of 29
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 1 Page 23 of 29 Agent Authorization Form 1. I am the customer of record of The United Illuminating Company / Eversource Energy (“EDC”) receiving electric transmission and distribution service at the following location ________________________ (“Location”). 2. I submitted a request for interconnection on __________with respect to the interconnection of a generating facility at the Location (the “Interconnection”). 3. I hereby appoint the following party as my authorized agent to act on my behalf with respect to all aspects of the Interconnection and Interconnection process: Name of Entity:__________________________________ Name of Individual:_______________________________ Address: ________________________________________ Phone Number: __________________________________ Email: _________________________________________ Fax: ___________________________________________ 4. I understand and agree that in naming the above party as my authorized agent for all aspects of the Interconnection, (i) EDC shall recognize such party as the primary point of contact for the Interconnection, (ii) such party shall receive all written and oral communication from EDC regarding the Interconnection, and (iii) such party may act and EDC shall take direction, without consulting me, regarding all matters related to the Interconnection, including but not limited to signing any and all documents required in connection with the Interconnection. I further understand and agree that the appointment of agent may only be revoked upon the express written notice by me to EDC at the following address {EDC Name and Address} and shall continue until EDC receives written notice of any such revocation by me. 5. I shall not hold EDC liable and I hereby release, indemnify and hold EDC harmless from and against any and all claims, liabilities, demands, causes of action or damages of any nature whatsoever against or incurred by EDC in connection with EDC’s reliance on the consents and authorizations reflected herein, including but not limited to EDC’s compliance with any instructions provided to it by my agent or any actions taken by my agent or EDC pursuant to such consents and authorizations. ____________________________________ Signature of Customer Print Name: Date: 23 Eversource - Internal UsePage 24 of 29
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 1 Page 24 of 29 Appendix A: Definitions Area Network: See Low Voltage Secondary Network Grid System Business Day: Shall mean Monday through Friday, excluding Federal and Connecticut Holidays. Capacity: The maximum output, commonly expressed in kilowatts (kW-AC) or megawatts (MW-AC), that generating equipment can supply to system load, adjusted for ambient conditions. Cease to Energize: Cessation of active power delivery under steady state and transient conditions and limitation of reactive power exchange. Certified Inverter-Based Generating Facility: Specific Generating Facility, 20kW and less and protective equipment system or systems that are documented as meeting applicable test requirements and standards relating to safety and reliability by a nationally recognized testing laboratory. An inverter is considered approved if it is certified to UL-1741 and passed the required tests without failure to comply with IEEE C62.41 and C62.45. Proof of certification under UL-1741 and IEEE C62.41, and C62.45 shall be required. Commissioning Test: Commissioning tests shall be conducted after the interconnection system is installed and is ready for operation. An individual qualified in testing protective equipment (professional engineer, factory certified technician, or licensed electrician with experience in testing protective equipment) must perform or directly supervise Commissioning tests. The EDC has the right to witness the Commissioning tests as described below, or to require written certification, by the equipment owner describing which tests were performed and their results. All commissioning tests shall be performed based on written procedures. Commissioning procedures are typically provided by equipment manufacturers or system integrators and approved by the equipment owner and the EDC. Once completed and accepted, the Commissioning tests will not have to be repeated unless set points are changed. Company (EDC) Facilitator: The EDC’s designated single point of contact for customer inquiries related to Facilities. Interested parties can obtain a copy of the Guidelines, interconnection applications and any forms that are needed to request an interconnection from the EDC Facilitator. 24 Eversource - Internal UsePage 25 of 29
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 1 Page 25 of 29 Continuous Operation: Exchange of current between the DER and an EPS within prescribed behavior while connected to the utility’s distribution system and while the applicable voltage and the system frequency is within specified parameters. Customer: The person, organization or entity applying to interconnect a Generating Facility to the EPS. Disconnect: To isolate a circuit or equipment from a source of power. Electric Distribution Company (“EDC”): The Connecticut Light and Power Company, doing business as Eversource Energy or The United Illuminating Company, as appropriate. Electric Power System (EPS): All electrical wires, equipment, and other facilities owned or provided by the EDC that are normally operated at voltages below 69kV to provide distribution service to customers. Eversource Energy: Eversource Energy provides service to all of Connecticut except the towns supplied by UI, and the towns of Wallingford, Norwich, Bozrah and parts of Groton, Norwalk, and Lebanon. Generator: The owner/operator of the Generating Facility. Generating Facility: Any certified inverter-based device producing electrical energy, i.e. rotating generators, wind, steam turbines, internal combustion engines, hydraulic turbines, solar, fuel cells, etc., including energy storage technologies. A system for the generation of electricity that is located near the point where the electricity will be used or is in a location that will support the functioning of the electric power distribution grid. Guidelines: The “Guidelines for Certified Inverter Based Generating Facility, 20kW or less”, which includes Attachments, that describe the protocols and procedures for interconnecting to the Electric Power System. IEEE: Institute of Electrical and Electronics Engineers. In-Service Date: The date on which the Generating Facility and system modification (if applicable) are complete and ready for service, even if the Generating Facility is not placed in service on or by that date 25 Eversource - Internal UsePage 26 of 29
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 1 Page 26 of 29 Interconnection: The physical connection of a Generating Facility to the Electric Power System so that Parallel Operation can occur. Interconnection Application (“Application”): The document to be completed by the Customer and sent to the EDC prior to any Interconnection. The Interconnection Application is in Section 5 of the Guidelines. By signing the Interconnection Application, the Customer acknowledges acceptance of all terms and conditions of the Guidelines. Inverter: A machine, device or system that changes direct-current power to alternating-current power. Islanding: A situation where electrical power remains in a portion of an EPS when the EPS has ceased providing power for whatever reason (emergency conditions, maintenance, etc.) to that portion of the EPS. Isolation Device (AC): A readily accessible, lockable, visible-break mechanical device used for isolating a circuit or equipment from a source of power. Low Voltage Secondary Network Grid System (Area Network): A Network Secondary Distribution System typically with a nominal voltage of 208Y/120 volts in which the secondaries of distribution transformers are connected to a common network bus through Network Protectors. The distribution transformers, Network Protectors and network buses are located in multiple locations which are interconnected to form a grid. Mandatory Operation: Required continuance of active current and reactive current exchange of DER with utility’s distribution voltage or frequency having magnitude and duration severity within defined limits. Momentary Cessation: Temporarily cease to energize the utility’s distribution system while connected to the utility’s distribution system, in response to a disturbance of the applicable voltages or system frequency, with the capability of immediate restore output of operation when the applicable voltages and the system frequency return to within defined ranges. Municipal Electrical Inspector: Local town or city official in which the Interconnection is proposed to take place who is responsible for approving the Interconnection. 26 Eversource - Internal UsePage 27 of 29
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 1 Page 27 of 29 Nationally Recognized Testing Laboratory (NRTL): An OSHA approved laboratory which performs the certification testing required for Generating Facilities. Net Metering: The process, in accordance with applicable EDC rates whereby the metered electrical energy production by a Generating Facility is subtracted from the metered EDC electrical energy sales to the customer at the Generating Facility. OSHA: Occupational Safety and Health Administration Parallel Operation: A Generating Facility, connected electrically to the EDC EPS, in which the potential exists for electricity to flow back from the Generating Facility to the EPS. The EDC will grant operation to parallel (energize) only when the products of the interconnection review conclude that the Generating Facility is in compliance with all EDC requirements. Parties: Those who are undertaking and agreeing to these Guidelines and the interconnection process, includes Customer and the EDC. Permissive Operation: Operating mode where the DER performs ride-through either in mandatory operation or in momentary cessation, in response to a disturbance of the applicable voltages or system frequency. PURA: Public Utilities Regulatory Authority Point of Interconnection: The point where the Generating Facility is electrically connected to the EDC EPS. Site Owner: a person who as legal ownership of a property and has the right to use it and has full control over it unless prevented by some agreement. The United Illuminating Company (“UI”). UI’s service area includes the principal cities of Bridgeport and New Haven and their surrounding municipalities: Ansonia, Derby, East Haven, Easton, Fairfield, Hamden, Milford, North Branford, North Haven, Orange, Shelton, Stratford, Trumbull, West Haven and Woodbridge. UL1741: Underwriters Laboratories Standard 1741 “Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources” as follows: Underwriters Laboratories Standard #1741 This standard addresses the electrical interconnection design of various forms of generating equipment. Manufacturers must submit their equipment to a Nationally Recognized Testing Laboratory (“NRTL”), recognized by OSHA, that verifies compliance 27 Eversource - Internal UsePage 28 of 29
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 1 Page 28 of 29 with UL1741. This "listing" is then marked on the equipment and supporting documentation. The Customer is responsible for ensuring compliance with all additional inverter base requirements per the UL1741, and with IEEE C62.41 and C62.45. UL1741SA: Underwriters Laboratories Standard 1741 Supplement A. addresses the testing and certification of advanced inverters for grid support functions. 28 Eversource - Internal UsePage 29 of 29
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 08, 2026 ICC-002 Attachment 1 Page 29 of 29 Appendix B: Codes and Standards Generating Facilities shall be in compliance with the latest version of IEEE 1547 series and UL 1741/UL 1741SA standards at the time of installation and commissioning. 29 Eversource - Internal Use
Text of ICC-002 Attachment 2.pdf
Extracted from the file · 74 pages · 148,550 characters
Text of ICC-002 Attachment 3.pdf
Extracted from the file · 27 pages · 91,051 characters
Text of ICC-004_Final.pdf
Extracted from the file · 1 page · 983 characters
Text of ICC-010_Final.pdf
Extracted from the file · 4 pages · 11,507 characters
Text of ICC-018_Final.pdf
Extracted from the file · 2 pages · 2,628 characters
As listed on the current system
Question(s) Answered 1, 2, 4, 10, 18, 20 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 09/22/2026